唇裂和/或腭裂新生儿数字模型与传统模型的准确性:基于实验室的研究

Children Pub Date : 2024-07-06 DOI:10.3390/children11070827
Jyotsna Unnikrishnan, Mahmoud Bakr, Robert Love, G. Idris
{"title":"唇裂和/或腭裂新生儿数字模型与传统模型的准确性:基于实验室的研究","authors":"Jyotsna Unnikrishnan, Mahmoud Bakr, Robert Love, G. Idris","doi":"10.3390/children11070827","DOIUrl":null,"url":null,"abstract":"Cleft lip and palate (CL/P) are a common congenital craniofacial anomaly requiring precise impressions for effective treatment. Conventional impressions (CIs) pose challenges in neonates with CL/P due to their delicate oral anatomy. While digital impressions (DIs) are increasingly recognised for their potential benefits over conventional methods in dentistry, their accuracy and application in neonates with cleft lip and palate (CL/P) remain underexplored. This study aimed to assess the accuracy of DIs compared to CIs in neonates with CL/P, using alginate and putty materials as references. A laboratory-based case–control study was conducted, utilising soft acrylic models resembling neonatal mouths with CL/P. Alginate and putty impressions were obtained conventionally, while digital impressions were captured using an intraoral scanner (IOS). A total of 42 models were analysed, divided evenly into three groups, with each group comprising 14 models. Superimposition and surface discrepancy analyses were performed to evaluate impression accuracy. The results revealed no statistically significant differences between the digital and conventional impressions in their intra-arch measurements and surface discrepancies. The mean measurement values did not significantly differ among groups, with p values indicating no significant variations (p > 0.05), confirmed by an analysis of variance. High intra-examiner reliability with Intra Class Coefficient (ICC) values close to 1 indicated consistent measurements over time. The current study demonstrates that DIs are equally accurate as conventional alginate and putty impressions in neonates with cleft lip and palate, offering a viable and less invasive alternative for clinical practise. This advancement holds promise for improving the treatment planning process and enhancing patient comfort, particularly in vulnerable neonatal populations. Further research is warranted to explore the clinical implications and factors affecting DI accuracy in this population.","PeriodicalId":9854,"journal":{"name":"Children","volume":" 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Accuracy of Digital Impressions versus Conventional Impressions in Neonates with Cleft Lip and/or Palate: A Laboratory-Based Study\",\"authors\":\"Jyotsna Unnikrishnan, Mahmoud Bakr, Robert Love, G. Idris\",\"doi\":\"10.3390/children11070827\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cleft lip and palate (CL/P) are a common congenital craniofacial anomaly requiring precise impressions for effective treatment. Conventional impressions (CIs) pose challenges in neonates with CL/P due to their delicate oral anatomy. While digital impressions (DIs) are increasingly recognised for their potential benefits over conventional methods in dentistry, their accuracy and application in neonates with cleft lip and palate (CL/P) remain underexplored. This study aimed to assess the accuracy of DIs compared to CIs in neonates with CL/P, using alginate and putty materials as references. A laboratory-based case–control study was conducted, utilising soft acrylic models resembling neonatal mouths with CL/P. Alginate and putty impressions were obtained conventionally, while digital impressions were captured using an intraoral scanner (IOS). A total of 42 models were analysed, divided evenly into three groups, with each group comprising 14 models. Superimposition and surface discrepancy analyses were performed to evaluate impression accuracy. The results revealed no statistically significant differences between the digital and conventional impressions in their intra-arch measurements and surface discrepancies. The mean measurement values did not significantly differ among groups, with p values indicating no significant variations (p > 0.05), confirmed by an analysis of variance. High intra-examiner reliability with Intra Class Coefficient (ICC) values close to 1 indicated consistent measurements over time. The current study demonstrates that DIs are equally accurate as conventional alginate and putty impressions in neonates with cleft lip and palate, offering a viable and less invasive alternative for clinical practise. This advancement holds promise for improving the treatment planning process and enhancing patient comfort, particularly in vulnerable neonatal populations. Further research is warranted to explore the clinical implications and factors affecting DI accuracy in this population.\",\"PeriodicalId\":9854,\"journal\":{\"name\":\"Children\",\"volume\":\" 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Children\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/children11070827\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Children","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/children11070827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

唇腭裂(CL/P)是一种常见的先天性颅面畸形,需要精确的印模才能有效治疗。由于患有唇腭裂的新生儿口腔解剖结构复杂,传统印模(CI)对他们来说是个挑战。虽然数字印模(DIs)因其比传统方法具有更多潜在优势而在牙科领域得到越来越多的认可,但其在唇腭裂(CL/P)新生儿中的准确性和应用仍未得到充分探索。本研究旨在以海藻酸盐和油灰材料为参考,评估唇腭裂新生儿DI与CI相比的准确性。研究采用与患有 CL/P 的新生儿口腔相似的软丙烯酸模型,进行了一项基于实验室的病例对照研究。藻酸盐和油灰印模以传统方式获得,而数字印模则使用口内扫描仪(IOS)采集。共分析了 42 个模型,平均分为三组,每组 14 个模型。通过叠加和表面差异分析来评估印模的准确性。结果显示,数字印模和传统印模在拱内测量和表面差异方面没有明显的统计学差异。经方差分析证实,各组之间的平均测量值没有明显差异,P 值显示无显著差异(P > 0.05)。检查者内部的可靠性很高,类内系数(ICC)值接近 1,表明测量结果在一段时间内保持一致。目前的研究表明,在唇腭裂新生儿中,DI 与传统的藻酸盐和油灰印模具有同等的准确性,为临床实践提供了一种可行的、创伤较小的替代方法。这一进步有望改善治疗规划过程,提高患者的舒适度,尤其是对脆弱的新生儿群体。我们有必要进一步开展研究,探讨对这一人群的临床影响以及影响 DI 准确性的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Accuracy of Digital Impressions versus Conventional Impressions in Neonates with Cleft Lip and/or Palate: A Laboratory-Based Study
Cleft lip and palate (CL/P) are a common congenital craniofacial anomaly requiring precise impressions for effective treatment. Conventional impressions (CIs) pose challenges in neonates with CL/P due to their delicate oral anatomy. While digital impressions (DIs) are increasingly recognised for their potential benefits over conventional methods in dentistry, their accuracy and application in neonates with cleft lip and palate (CL/P) remain underexplored. This study aimed to assess the accuracy of DIs compared to CIs in neonates with CL/P, using alginate and putty materials as references. A laboratory-based case–control study was conducted, utilising soft acrylic models resembling neonatal mouths with CL/P. Alginate and putty impressions were obtained conventionally, while digital impressions were captured using an intraoral scanner (IOS). A total of 42 models were analysed, divided evenly into three groups, with each group comprising 14 models. Superimposition and surface discrepancy analyses were performed to evaluate impression accuracy. The results revealed no statistically significant differences between the digital and conventional impressions in their intra-arch measurements and surface discrepancies. The mean measurement values did not significantly differ among groups, with p values indicating no significant variations (p > 0.05), confirmed by an analysis of variance. High intra-examiner reliability with Intra Class Coefficient (ICC) values close to 1 indicated consistent measurements over time. The current study demonstrates that DIs are equally accurate as conventional alginate and putty impressions in neonates with cleft lip and palate, offering a viable and less invasive alternative for clinical practise. This advancement holds promise for improving the treatment planning process and enhancing patient comfort, particularly in vulnerable neonatal populations. Further research is warranted to explore the clinical implications and factors affecting DI accuracy in this population.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信