肩锁韧带上端受损时肩锁关节的应力变形状态和各种固定方法

Olexander A Buryanov, V. Kvasha, D. Chekushyn, Mykhailo Zadnychenko, Mykhailo Karpinsky, Olexander Yaresko
{"title":"肩锁韧带上端受损时肩锁关节的应力变形状态和各种固定方法","authors":"Olexander A Buryanov, V. Kvasha, D. Chekushyn, Mykhailo Zadnychenko, Mykhailo Karpinsky, Olexander Yaresko","doi":"10.15674/0030-59872024233-41","DOIUrl":null,"url":null,"abstract":"During the operative stabilization of the acromial end of the clavicle (AEC) for its dislocation, there are two ways: clavicle – beaklike process, clavicle – acromial process. Fixation of the AEC to the acromial process of the scapula is a priority. Competing metal structures are the hook plate and the Weber method. The significant disadvantages of using the Weber method of fixation are the migration of the tips and the violation of their integrity andthe wire. Objective. To conduct a comparative analysis of the fixation of the acromial end of the clavicle according to Weber, hook plate and the proposed construction, by studying the stressed-deformed state of the clavicular-acromial joint in case of damage to the lig. acromioclavicular superior and various methods of fixation. Methods. A finite-element model of the clavicular-acromial joint was constructed. Damage to the ligaments was modeled. claviculo-acoacromiale superior, as well as fixation of AEC in three ways: according to Weber, hook plate and the proposed construction. Results. The best results, from the point of view of reducing the level of stresses in intact ligaments, are provided by fixation of the AEC according to Weber, but its use leadsto an increase in the level of stresses on the AEC and the acromial process of the scapula, which can cause destruction of the latter. The hinge-type fixator provides the best stress distribution, both in the bony elements of the model and in intact ligaments. The hook plate holder occupies an average position,both in terms of the level of stress and the magnitude of the relative deformations in the ligaments. Conclusions. Weber fixation provides the best results for reducing the level of stresses and relative strains in the intact ligaments, but leads to a several-fold increase in the level of stresses on the AEC and acromial process of the scapula. The hook plate holder occupies an average position, both in terms of the stress level and the magnitude of the relativedeformations in the ligaments. The proposed design provides the best stress distribution, both in the bony elements of the model and in the intact ligaments.","PeriodicalId":137495,"journal":{"name":"ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS","volume":"123 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"STRESS-DEFORMED STATE OF THE ACROMIOCLAVICULAR JOINT IN CASE OF DAMAGE TO THE UPPER ACROMIOCLAVICULAR LIGAMENT SUPERIOR AND VARIOUS METHODS OF FIXATION\",\"authors\":\"Olexander A Buryanov, V. Kvasha, D. Chekushyn, Mykhailo Zadnychenko, Mykhailo Karpinsky, Olexander Yaresko\",\"doi\":\"10.15674/0030-59872024233-41\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During the operative stabilization of the acromial end of the clavicle (AEC) for its dislocation, there are two ways: clavicle – beaklike process, clavicle – acromial process. Fixation of the AEC to the acromial process of the scapula is a priority. Competing metal structures are the hook plate and the Weber method. The significant disadvantages of using the Weber method of fixation are the migration of the tips and the violation of their integrity andthe wire. Objective. To conduct a comparative analysis of the fixation of the acromial end of the clavicle according to Weber, hook plate and the proposed construction, by studying the stressed-deformed state of the clavicular-acromial joint in case of damage to the lig. acromioclavicular superior and various methods of fixation. Methods. A finite-element model of the clavicular-acromial joint was constructed. Damage to the ligaments was modeled. claviculo-acoacromiale superior, as well as fixation of AEC in three ways: according to Weber, hook plate and the proposed construction. Results. The best results, from the point of view of reducing the level of stresses in intact ligaments, are provided by fixation of the AEC according to Weber, but its use leadsto an increase in the level of stresses on the AEC and the acromial process of the scapula, which can cause destruction of the latter. The hinge-type fixator provides the best stress distribution, both in the bony elements of the model and in intact ligaments. The hook plate holder occupies an average position,both in terms of the level of stress and the magnitude of the relative deformations in the ligaments. Conclusions. Weber fixation provides the best results for reducing the level of stresses and relative strains in the intact ligaments, but leads to a several-fold increase in the level of stresses on the AEC and acromial process of the scapula. The hook plate holder occupies an average position, both in terms of the stress level and the magnitude of the relativedeformations in the ligaments. The proposed design provides the best stress distribution, both in the bony elements of the model and in the intact ligaments.\",\"PeriodicalId\":137495,\"journal\":{\"name\":\"ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS\",\"volume\":\"123 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15674/0030-59872024233-41\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15674/0030-59872024233-41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在锁骨肩峰端(AEC)脱位的手术稳定过程中,有两种方法:锁骨-喙状突法、锁骨-肩峰突法。将 AEC 固定在肩胛骨的肩峰突上是当务之急。与之竞争的金属结构有钩板和韦伯法。使用韦伯固定法的主要缺点是尖端移位、破坏其完整性和金属丝。目的。通过研究锁骨-肩峰上韧带受损时锁骨-肩峰关节的受力变形状态以及各种固定方法,对韦伯法、钩板法和拟议结构的锁骨肩峰端固定方法进行比较分析。方法。建立了锁骨-肩峰关节的有限元模型。对锁骨-肩峰上韧带的损伤以及 AEC 的三种固定方法进行了建模:根据 Weber、钩板和建议的结构。结果。从降低完整韧带应力水平的角度来看,根据韦伯法固定 AEC 的效果最好,但使用这种方法会导致 AEC 和肩胛骨肩峰突的应力水平增加,从而导致后者的破坏。铰链式固定器在模型的骨质元素和完整韧带上都能提供最佳的应力分布。就应力水平和韧带的相对变形量而言,钩板固定器处于平均位置。结论韦伯固定在降低完整韧带的应力水平和相对应变方面效果最佳,但会导致肩胛骨AEC和肩峰突的应力水平增加数倍。就韧带的应力水平和相对变形量而言,钩板固定器处于平均位置。无论是在模型的骨质元素中还是在完整的韧带中,拟议的设计都提供了最佳的应力分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
STRESS-DEFORMED STATE OF THE ACROMIOCLAVICULAR JOINT IN CASE OF DAMAGE TO THE UPPER ACROMIOCLAVICULAR LIGAMENT SUPERIOR AND VARIOUS METHODS OF FIXATION
During the operative stabilization of the acromial end of the clavicle (AEC) for its dislocation, there are two ways: clavicle – beaklike process, clavicle – acromial process. Fixation of the AEC to the acromial process of the scapula is a priority. Competing metal structures are the hook plate and the Weber method. The significant disadvantages of using the Weber method of fixation are the migration of the tips and the violation of their integrity andthe wire. Objective. To conduct a comparative analysis of the fixation of the acromial end of the clavicle according to Weber, hook plate and the proposed construction, by studying the stressed-deformed state of the clavicular-acromial joint in case of damage to the lig. acromioclavicular superior and various methods of fixation. Methods. A finite-element model of the clavicular-acromial joint was constructed. Damage to the ligaments was modeled. claviculo-acoacromiale superior, as well as fixation of AEC in three ways: according to Weber, hook plate and the proposed construction. Results. The best results, from the point of view of reducing the level of stresses in intact ligaments, are provided by fixation of the AEC according to Weber, but its use leadsto an increase in the level of stresses on the AEC and the acromial process of the scapula, which can cause destruction of the latter. The hinge-type fixator provides the best stress distribution, both in the bony elements of the model and in intact ligaments. The hook plate holder occupies an average position,both in terms of the level of stress and the magnitude of the relative deformations in the ligaments. Conclusions. Weber fixation provides the best results for reducing the level of stresses and relative strains in the intact ligaments, but leads to a several-fold increase in the level of stresses on the AEC and acromial process of the scapula. The hook plate holder occupies an average position, both in terms of the stress level and the magnitude of the relativedeformations in the ligaments. The proposed design provides the best stress distribution, both in the bony elements of the model and in the intact ligaments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信