Chang Yu Kuo, Ying Kuan Tsai, Jo Yen Nieh, Yi Shiuan Tian
{"title":"防护设施用超高强度混凝土的电磁屏蔽效果和抗冲击性实验研究","authors":"Chang Yu Kuo, Ying Kuan Tsai, Jo Yen Nieh, Yi Shiuan Tian","doi":"10.4028/p-ola9so","DOIUrl":null,"url":null,"abstract":"The research was conducted on incorporating short carbon fiber and multi-layer graphene into ultra-high performance concrete (UHPC) to improve the dynamic mechanical performance and electromagnetic shielding effectiveness (SE). In the electromagnetic shielding effectiveness testing, the results shown that UHPC with uniformly distributed conductive fibers exhibited superior shielding effectiveness at high frequencies. In comparison to normal concrete, the UHPC demonstrated the capability to withstand higher impact energy. Simultaneously enhancing both electromagnetic shielding characteristics and dynamic mechanical performance of cementitious materials can be challenging. In this study, employing a composite structure was effective solution to overcome this issue. In accordance with the experimental results, a scaled testing protective facility has been constructed, and the research results could provide the reference for the design and construction of protective structures.","PeriodicalId":17714,"journal":{"name":"Key Engineering Materials","volume":"82 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Experimental Study on Electromagnetic Shielding Effectiveness and Impact Resistance of UHPC for Protective Facilities\",\"authors\":\"Chang Yu Kuo, Ying Kuan Tsai, Jo Yen Nieh, Yi Shiuan Tian\",\"doi\":\"10.4028/p-ola9so\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The research was conducted on incorporating short carbon fiber and multi-layer graphene into ultra-high performance concrete (UHPC) to improve the dynamic mechanical performance and electromagnetic shielding effectiveness (SE). In the electromagnetic shielding effectiveness testing, the results shown that UHPC with uniformly distributed conductive fibers exhibited superior shielding effectiveness at high frequencies. In comparison to normal concrete, the UHPC demonstrated the capability to withstand higher impact energy. Simultaneously enhancing both electromagnetic shielding characteristics and dynamic mechanical performance of cementitious materials can be challenging. In this study, employing a composite structure was effective solution to overcome this issue. In accordance with the experimental results, a scaled testing protective facility has been constructed, and the research results could provide the reference for the design and construction of protective structures.\",\"PeriodicalId\":17714,\"journal\":{\"name\":\"Key Engineering Materials\",\"volume\":\"82 11\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Key Engineering Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4028/p-ola9so\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Key Engineering Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-ola9so","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An Experimental Study on Electromagnetic Shielding Effectiveness and Impact Resistance of UHPC for Protective Facilities
The research was conducted on incorporating short carbon fiber and multi-layer graphene into ultra-high performance concrete (UHPC) to improve the dynamic mechanical performance and electromagnetic shielding effectiveness (SE). In the electromagnetic shielding effectiveness testing, the results shown that UHPC with uniformly distributed conductive fibers exhibited superior shielding effectiveness at high frequencies. In comparison to normal concrete, the UHPC demonstrated the capability to withstand higher impact energy. Simultaneously enhancing both electromagnetic shielding characteristics and dynamic mechanical performance of cementitious materials can be challenging. In this study, employing a composite structure was effective solution to overcome this issue. In accordance with the experimental results, a scaled testing protective facility has been constructed, and the research results could provide the reference for the design and construction of protective structures.