周期性阶梯开放式微型针翅散热器的热液压对比分析

Pub Date : 2024-07-12 DOI:10.24425/ather.2024.151228
P. Bhandari, Bhavesh Vyas, Diwakar Padalia, Lalit Ranakoti, Y. Prajapati, Raghubeer S. Bangari
{"title":"周期性阶梯开放式微型针翅散热器的热液压对比分析","authors":"P. Bhandari, Bhavesh Vyas, Diwakar Padalia, Lalit Ranakoti, Y. Prajapati, Raghubeer S. Bangari","doi":"10.24425/ather.2024.151228","DOIUrl":null,"url":null,"abstract":"There is no doubt that the miniaturization of various electronic devices, including processors, servers, micro-electromechan-ical system devices, etc. has resulted in increased overall performance. However, there is a major problem with thermal management in these devices, as well as in many others. One of the most promising solutions is liquid cooled microchannel heat sink. In the current work, different cases of open micro pin-fin configurations of heat sink were considered. The con-figurations considered were a uniform height micro pin-fin heat sink, three-stepped unidirectional micro pin-fin heat sink and three-stepped bi-directional micro pin-fin heat sink. These configurations were also oriented in two dissimilar fashions, i.e. inline and staggered, so the total of six heat sink configurations are compared and analysed. Using single phase water as a coolant and copper as a substrate, these configurations were simulated numerically for different Reynolds numbers (10−160) under heat flux of 500 kW/m2. It can be concluded that at low Reynolds numbers, steepness does not contribute much in both inline and staggered arrangements, while at higher Reynolds numbers, 3 stepped staggered configurations has revealed the best performance due to boosted fluid mixing and more projecting secondary flow. Furthermore, bi-direction-ality in steepness shows augmented performance only in inline arrangement.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative thermo-hydraulic analysis of periodic stepped open micro pin-fin heat sink\",\"authors\":\"P. Bhandari, Bhavesh Vyas, Diwakar Padalia, Lalit Ranakoti, Y. Prajapati, Raghubeer S. Bangari\",\"doi\":\"10.24425/ather.2024.151228\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There is no doubt that the miniaturization of various electronic devices, including processors, servers, micro-electromechan-ical system devices, etc. has resulted in increased overall performance. However, there is a major problem with thermal management in these devices, as well as in many others. One of the most promising solutions is liquid cooled microchannel heat sink. In the current work, different cases of open micro pin-fin configurations of heat sink were considered. The con-figurations considered were a uniform height micro pin-fin heat sink, three-stepped unidirectional micro pin-fin heat sink and three-stepped bi-directional micro pin-fin heat sink. These configurations were also oriented in two dissimilar fashions, i.e. inline and staggered, so the total of six heat sink configurations are compared and analysed. Using single phase water as a coolant and copper as a substrate, these configurations were simulated numerically for different Reynolds numbers (10−160) under heat flux of 500 kW/m2. It can be concluded that at low Reynolds numbers, steepness does not contribute much in both inline and staggered arrangements, while at higher Reynolds numbers, 3 stepped staggered configurations has revealed the best performance due to boosted fluid mixing and more projecting secondary flow. Furthermore, bi-direction-ality in steepness shows augmented performance only in inline arrangement.\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2024-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/ather.2024.151228\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/ather.2024.151228","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

毫无疑问,各种电子设备(包括处理器、服务器、微型机电系统设备等)的微型化提高了整体性能。然而,这些设备以及许多其他设备在热管理方面都存在一个重大问题。液冷微通道散热器是最有前途的解决方案之一。在目前的工作中,考虑了不同情况下的开放式微型针脚鳍片散热器配置。所考虑的配置包括均匀高度的微型针脚鳍片散热器、三阶梯单向微型针脚鳍片散热器和三阶梯双向微型针脚鳍片散热器。这些配置还采用了两种不同的取向,即直列和交错取向,因此共对六种散热器配置进行了比较和分析。以单相水为冷却剂,铜为基板,在热流量为 500 kW/m2 的条件下,对这些配置进行了不同雷诺数(10-160)的数值模拟。可以得出的结论是,在低雷诺数时,陡度对直列式和交错式布置的影响不大,而在较高雷诺数时,3 阶交错式配置由于增强了流体混合和更多的二次流投射而显示出最佳性能。此外,陡度的双向性仅在直列布置中显示出更好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
Comparative thermo-hydraulic analysis of periodic stepped open micro pin-fin heat sink
There is no doubt that the miniaturization of various electronic devices, including processors, servers, micro-electromechan-ical system devices, etc. has resulted in increased overall performance. However, there is a major problem with thermal management in these devices, as well as in many others. One of the most promising solutions is liquid cooled microchannel heat sink. In the current work, different cases of open micro pin-fin configurations of heat sink were considered. The con-figurations considered were a uniform height micro pin-fin heat sink, three-stepped unidirectional micro pin-fin heat sink and three-stepped bi-directional micro pin-fin heat sink. These configurations were also oriented in two dissimilar fashions, i.e. inline and staggered, so the total of six heat sink configurations are compared and analysed. Using single phase water as a coolant and copper as a substrate, these configurations were simulated numerically for different Reynolds numbers (10−160) under heat flux of 500 kW/m2. It can be concluded that at low Reynolds numbers, steepness does not contribute much in both inline and staggered arrangements, while at higher Reynolds numbers, 3 stepped staggered configurations has revealed the best performance due to boosted fluid mixing and more projecting secondary flow. Furthermore, bi-direction-ality in steepness shows augmented performance only in inline arrangement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信