皮质骨厚度对正畸微型螺钉-骨界面剪应力和力的影响--有限元分析。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Balamurali V, Varadaraju Magesh, Pandurangan Harikrishnan
{"title":"皮质骨厚度对正畸微型螺钉-骨界面剪应力和力的影响--有限元分析。","authors":"Balamurali V, Varadaraju Magesh, Pandurangan Harikrishnan","doi":"10.1088/2057-1976/ad6160","DOIUrl":null,"url":null,"abstract":"<p><p>Miniscrews are widely used in orthodontics as an anchorage device while aligning teeth. Shear stress in the miniscrew-bone interface is an important factor when the miniscrew makes contact with the bone. The objective of this study was to analyze the shear stress and force in the screw-bone interface for varying Cortical Bone Thickness (CBT) using Finite Element Analysis (FEA). Varying CBT of 1.09 mm (1.09<sub>CBT</sub>) and 2.66 mm (2.66<sub>CBT</sub>) with miniscrews of Ø1.2 mm, 10 mm length (T1), Ø1.2 mm, 6 mm length (T2) and Ø1.6 mm, 8 mm length (T3) were analyzed. Six Finite Element (FE) models were developed with cortical, cancellous bone, miniscrews and gingiva as a prism. A deflection of 0.1 mm was applied on the neck of the miniscrews at 0°, +30° and -30° angles. The shear stress and force in the screw-bone interface were assessed. The results showed that the CBT affects the shear stress and force in the screw-bone interface region in addition to the screw dimensions and deflection angulations. T1 screw generated lesser shear stress in 1.09<sub>CBT</sub>and 2.66<sub>CBT</sub>compared to T2 and T3 screws. Higher CBT is preferred for better primary stability in shear aspect. Clinically applied forces of 200 gms to 300 gms to an anchorage device induces shear stress in the miniscrew-bone interface region might cause stress shielding. Thus, clinicians need to consider the effect of varying CBT and the size of the miniscrews for the stability, reduced stress shielding and better anchorage during orthodontic treatment.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of cortical bone thickness on shear stress and force in orthodontic miniscrew-bone interface - A finite element analysis.\",\"authors\":\"Balamurali V, Varadaraju Magesh, Pandurangan Harikrishnan\",\"doi\":\"10.1088/2057-1976/ad6160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Miniscrews are widely used in orthodontics as an anchorage device while aligning teeth. Shear stress in the miniscrew-bone interface is an important factor when the miniscrew makes contact with the bone. The objective of this study was to analyze the shear stress and force in the screw-bone interface for varying Cortical Bone Thickness (CBT) using Finite Element Analysis (FEA). Varying CBT of 1.09 mm (1.09<sub>CBT</sub>) and 2.66 mm (2.66<sub>CBT</sub>) with miniscrews of Ø1.2 mm, 10 mm length (T1), Ø1.2 mm, 6 mm length (T2) and Ø1.6 mm, 8 mm length (T3) were analyzed. Six Finite Element (FE) models were developed with cortical, cancellous bone, miniscrews and gingiva as a prism. A deflection of 0.1 mm was applied on the neck of the miniscrews at 0°, +30° and -30° angles. The shear stress and force in the screw-bone interface were assessed. The results showed that the CBT affects the shear stress and force in the screw-bone interface region in addition to the screw dimensions and deflection angulations. T1 screw generated lesser shear stress in 1.09<sub>CBT</sub>and 2.66<sub>CBT</sub>compared to T2 and T3 screws. Higher CBT is preferred for better primary stability in shear aspect. Clinically applied forces of 200 gms to 300 gms to an anchorage device induces shear stress in the miniscrew-bone interface region might cause stress shielding. Thus, clinicians need to consider the effect of varying CBT and the size of the miniscrews for the stability, reduced stress shielding and better anchorage during orthodontic treatment.</p>\",\"PeriodicalId\":8896,\"journal\":{\"name\":\"Biomedical Physics & Engineering Express\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Physics & Engineering Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2057-1976/ad6160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad6160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

微型螺钉被广泛应用于牙齿矫正中,作为牙齿排列时的固定装置。微型螺钉与骨接触时,骨与微型螺钉界面的剪应力是一个重要因素。本研究的目的是使用有限元分析法(FEA)分析不同皮质骨厚度(CBT)下螺钉-骨界面的剪应力和力。分析了 1.09 毫米(1.09CBT)和 2.66 毫米(2.66CBT)的不同 CBT,以及直径 1.2 毫米、长度 10 毫米(T1)、直径 1.2 毫米、长度 6 毫米(T2)和直径 1.6 毫米、长度 8 毫米(T3)的微型螺钉。以皮质骨、松质骨、微型螺钉和牙龈为棱柱,建立了六个有限元(FE)模型。在 0°、+30° 和 -30° 角上对迷你螺钉的颈部施加 0.1 毫米的挠度。对螺钉-骨界面的剪应力和力进行了评估。结果表明,除了螺钉尺寸和偏转角度外,CBT 也会影响螺钉-骨界面区域的剪应力和力。与 T2 和 T3 螺钉相比,T1 螺钉在 1.09CBT 和 2.66CBT 产生的剪应力较小。较高的 CBT 更有利于提高剪切方面的基本稳定性。临床上对锚固装置施加 200 至 300 克的力会在微型螺钉-骨界面区域产生剪应力,可能会导致应力屏蔽。因此,临床医生需要考虑不同的 CBT 和微型螺钉大小对正畸治疗期间的稳定性、减少应力屏蔽和更好的锚固效果的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of cortical bone thickness on shear stress and force in orthodontic miniscrew-bone interface - A finite element analysis.

Miniscrews are widely used in orthodontics as an anchorage device while aligning teeth. Shear stress in the miniscrew-bone interface is an important factor when the miniscrew makes contact with the bone. The objective of this study was to analyze the shear stress and force in the screw-bone interface for varying Cortical Bone Thickness (CBT) using Finite Element Analysis (FEA). Varying CBT of 1.09 mm (1.09CBT) and 2.66 mm (2.66CBT) with miniscrews of Ø1.2 mm, 10 mm length (T1), Ø1.2 mm, 6 mm length (T2) and Ø1.6 mm, 8 mm length (T3) were analyzed. Six Finite Element (FE) models were developed with cortical, cancellous bone, miniscrews and gingiva as a prism. A deflection of 0.1 mm was applied on the neck of the miniscrews at 0°, +30° and -30° angles. The shear stress and force in the screw-bone interface were assessed. The results showed that the CBT affects the shear stress and force in the screw-bone interface region in addition to the screw dimensions and deflection angulations. T1 screw generated lesser shear stress in 1.09CBTand 2.66CBTcompared to T2 and T3 screws. Higher CBT is preferred for better primary stability in shear aspect. Clinically applied forces of 200 gms to 300 gms to an anchorage device induces shear stress in the miniscrew-bone interface region might cause stress shielding. Thus, clinicians need to consider the effect of varying CBT and the size of the miniscrews for the stability, reduced stress shielding and better anchorage during orthodontic treatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信