用于大体积等离子体分析的能量消耗飞行时间质谱仪。

IF 3.1 2区 化学 Q2 BIOCHEMICAL RESEARCH METHODS
Malte Watzek, Patrick Sturm, Carsten Stoermer, Abdelhak Bensaoula, Thomas Nelis, Caroline Hain
{"title":"用于大体积等离子体分析的能量消耗飞行时间质谱仪。","authors":"Malte Watzek, Patrick Sturm, Carsten Stoermer, Abdelhak Bensaoula, Thomas Nelis, Caroline Hain","doi":"10.1021/jasms.4c00140","DOIUrl":null,"url":null,"abstract":"<p><p>This work presents a newly designed energy-resolving time-of-flight mass spectrometer (E-TOFMS) for analysing the energy and mass of ions in bulk plasma. The system comprises an electrostatic sector analyser (ESA) for energy-to-charge (E/Q) ratio resolution and an orthogonal reflectron TOFMS for mass-to-charge (m/Q) ratio analysis. The design choices are explained, providing insight into electron and ion path simulations. The instrument was characterised using various ion generation sources, including an electron impact ion source, high power impulse magnetron sputtering, and microwave plasma electron cyclotron resonance sources. To validate its functionality, the energy-resolving data was compared with data obtained under the same conditions using a Langmuir probe and a retarding field energy analyser (RFEA). The benefits of the proposed E-TOFMS were demonstrated by sputtering highly alloyed steel with multiple isotope-rich elements, such as Mo or W. This technique offers an E/Q ratio resolution of up to 0.15 V for a range up to 125 V and a m/Q ratio resolution of at least 700 Th for a range up to 250 Th, with a temporal resolution of 10 μs.</p>","PeriodicalId":672,"journal":{"name":"Journal of the American Society for Mass Spectrometry","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11311225/pdf/","citationCount":"0","resultStr":"{\"title\":\"Energy-Resolving Time-of-Flight Mass Spectrometry for Bulk Plasma Analysis.\",\"authors\":\"Malte Watzek, Patrick Sturm, Carsten Stoermer, Abdelhak Bensaoula, Thomas Nelis, Caroline Hain\",\"doi\":\"10.1021/jasms.4c00140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This work presents a newly designed energy-resolving time-of-flight mass spectrometer (E-TOFMS) for analysing the energy and mass of ions in bulk plasma. The system comprises an electrostatic sector analyser (ESA) for energy-to-charge (E/Q) ratio resolution and an orthogonal reflectron TOFMS for mass-to-charge (m/Q) ratio analysis. The design choices are explained, providing insight into electron and ion path simulations. The instrument was characterised using various ion generation sources, including an electron impact ion source, high power impulse magnetron sputtering, and microwave plasma electron cyclotron resonance sources. To validate its functionality, the energy-resolving data was compared with data obtained under the same conditions using a Langmuir probe and a retarding field energy analyser (RFEA). The benefits of the proposed E-TOFMS were demonstrated by sputtering highly alloyed steel with multiple isotope-rich elements, such as Mo or W. This technique offers an E/Q ratio resolution of up to 0.15 V for a range up to 125 V and a m/Q ratio resolution of at least 700 Th for a range up to 250 Th, with a temporal resolution of 10 μs.</p>\",\"PeriodicalId\":672,\"journal\":{\"name\":\"Journal of the American Society for Mass Spectrometry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11311225/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Society for Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/jasms.4c00140\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society for Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/jasms.4c00140","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

本研究介绍了一种新设计的能量分辨飞行时间质谱仪(E-TOFMS),用于分析大体积等离子体中离子的能量和质量。该系统包括一个用于能量-电荷(E/Q)比分辨率的静电扇区分析仪(ESA)和一个用于质量-电荷(m/Q)比分析的正交反射式飞行时间质谱仪(TOFMS)。对设计选择进行了解释,并对电子和离子路径模拟进行了深入分析。该仪器利用各种离子发生源进行了鉴定,包括电子撞击离子源、高功率脉冲磁控溅射和微波等离子电子回旋共振源。为了验证其功能,将能量分辨数据与使用朗缪尔探针和阻滞场能量分析仪(RFEA)在相同条件下获得的数据进行了比较。通过对含有多种富同位素元素(如钼或钨)的高合金钢进行溅射,证明了所建议的 E-TOFMS 的优势。该技术的 E/Q 比分辨率高达 0.15 V(范围高达 125 V),m/Q 比分辨率至少为 700 Th(范围高达 250 Th),时间分辨率为 10 μs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Energy-Resolving Time-of-Flight Mass Spectrometry for Bulk Plasma Analysis.

Energy-Resolving Time-of-Flight Mass Spectrometry for Bulk Plasma Analysis.

This work presents a newly designed energy-resolving time-of-flight mass spectrometer (E-TOFMS) for analysing the energy and mass of ions in bulk plasma. The system comprises an electrostatic sector analyser (ESA) for energy-to-charge (E/Q) ratio resolution and an orthogonal reflectron TOFMS for mass-to-charge (m/Q) ratio analysis. The design choices are explained, providing insight into electron and ion path simulations. The instrument was characterised using various ion generation sources, including an electron impact ion source, high power impulse magnetron sputtering, and microwave plasma electron cyclotron resonance sources. To validate its functionality, the energy-resolving data was compared with data obtained under the same conditions using a Langmuir probe and a retarding field energy analyser (RFEA). The benefits of the proposed E-TOFMS were demonstrated by sputtering highly alloyed steel with multiple isotope-rich elements, such as Mo or W. This technique offers an E/Q ratio resolution of up to 0.15 V for a range up to 125 V and a m/Q ratio resolution of at least 700 Th for a range up to 250 Th, with a temporal resolution of 10 μs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.50
自引率
9.40%
发文量
257
审稿时长
1 months
期刊介绍: The Journal of the American Society for Mass Spectrometry presents research papers covering all aspects of mass spectrometry, incorporating coverage of fields of scientific inquiry in which mass spectrometry can play a role. Comprehensive in scope, the journal publishes papers on both fundamentals and applications of mass spectrometry. Fundamental subjects include instrumentation principles, design, and demonstration, structures and chemical properties of gas-phase ions, studies of thermodynamic properties, ion spectroscopy, chemical kinetics, mechanisms of ionization, theories of ion fragmentation, cluster ions, and potential energy surfaces. In addition to full papers, the journal offers Communications, Application Notes, and Accounts and Perspectives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信