用于股动脉瘤修复的 Viabahn 内膜假体:安全性、成功率和长期通畅性。

IF 1.2 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Jan M Brendel, Tobias Mangold, Markus Pfändler, Benedikt Stenzl, Mateja Andic, Jonas Mück, Jörg Schmehl, Patrick Krumm, Christoph Artzner, Gerd Grözinger, Arne Estler
{"title":"用于股动脉瘤修复的 Viabahn 内膜假体:安全性、成功率和长期通畅性。","authors":"Jan M Brendel, Tobias Mangold, Markus Pfändler, Benedikt Stenzl, Mateja Andic, Jonas Mück, Jörg Schmehl, Patrick Krumm, Christoph Artzner, Gerd Grözinger, Arne Estler","doi":"10.1186/s42155-024-00465-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Viabahn endoprosthesis has become a vital option for endovascular therapy, yet there is limited long-term data on its effectiveness for peripheral aneurysm repair. This study aimed to evaluate the safety, technical and clinical success, and long-term patency of the Viabahn endoprosthesis for treating femoropopliteal aneurysms.</p><p><strong>Methods: </strong>This retrospective tertiary single-center study analyzed patients who underwent a Viabahn endoprosthesis procedure for femoropopliteal aneurysm repair from 2010 to 2020. Intraoperative complications, technical and clinical success rates, and major adverse events (MAE, including acute thrombotic occlusion, major amputation, myocardial infarction, and device- or procedure-related death) at 30 days were assessed. Incidence of clinically-driven target lesion revascularisation (cdTLR) was noted. Patency rates were evaluated by Kaplan-Meier analysis.</p><p><strong>Results: </strong>Among 19 patients (mean age, 72 ± 12 years; 18 male, 1 female) who underwent aneurysm repair using the Viabahn endoprosthesis, there were no intraoperative adverse events, with 100% technical and clinical success rates. At the 30-day mark, all patients (19/19, 100%) were free of MAE. The median follow-up duration was 1,009 days [IQR, 462-1,466]. Popliteal stent graft occlusion occurred in 2/19 patients (10.5%) after 27 and 45 months, respectively. Consequently, the primary patency rates were 100%, 90%, 74% at 12, 24, and 36-72 months, respectively. Endovascular cdTLR was successful in both cases, resulting in sustained secondary patency at 100%.</p><p><strong>Conclusion: </strong>The use of Viabahn endoprostheses for femoropopliteal aneurysm repair demonstrated technical and clinical success rates of 100%, a 0% 30-day MAE rate, and excellent long-term patency.</p>","PeriodicalId":52351,"journal":{"name":"CVIR Endovascular","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11231120/pdf/","citationCount":"0","resultStr":"{\"title\":\"Viabahn endoprosthesis for femoropopliteal aneurysm repair: safety, success rates, and long-term patency.\",\"authors\":\"Jan M Brendel, Tobias Mangold, Markus Pfändler, Benedikt Stenzl, Mateja Andic, Jonas Mück, Jörg Schmehl, Patrick Krumm, Christoph Artzner, Gerd Grözinger, Arne Estler\",\"doi\":\"10.1186/s42155-024-00465-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Viabahn endoprosthesis has become a vital option for endovascular therapy, yet there is limited long-term data on its effectiveness for peripheral aneurysm repair. This study aimed to evaluate the safety, technical and clinical success, and long-term patency of the Viabahn endoprosthesis for treating femoropopliteal aneurysms.</p><p><strong>Methods: </strong>This retrospective tertiary single-center study analyzed patients who underwent a Viabahn endoprosthesis procedure for femoropopliteal aneurysm repair from 2010 to 2020. Intraoperative complications, technical and clinical success rates, and major adverse events (MAE, including acute thrombotic occlusion, major amputation, myocardial infarction, and device- or procedure-related death) at 30 days were assessed. Incidence of clinically-driven target lesion revascularisation (cdTLR) was noted. Patency rates were evaluated by Kaplan-Meier analysis.</p><p><strong>Results: </strong>Among 19 patients (mean age, 72 ± 12 years; 18 male, 1 female) who underwent aneurysm repair using the Viabahn endoprosthesis, there were no intraoperative adverse events, with 100% technical and clinical success rates. At the 30-day mark, all patients (19/19, 100%) were free of MAE. The median follow-up duration was 1,009 days [IQR, 462-1,466]. Popliteal stent graft occlusion occurred in 2/19 patients (10.5%) after 27 and 45 months, respectively. Consequently, the primary patency rates were 100%, 90%, 74% at 12, 24, and 36-72 months, respectively. Endovascular cdTLR was successful in both cases, resulting in sustained secondary patency at 100%.</p><p><strong>Conclusion: </strong>The use of Viabahn endoprostheses for femoropopliteal aneurysm repair demonstrated technical and clinical success rates of 100%, a 0% 30-day MAE rate, and excellent long-term patency.</p>\",\"PeriodicalId\":52351,\"journal\":{\"name\":\"CVIR Endovascular\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11231120/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CVIR Endovascular\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s42155-024-00465-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CVIR Endovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42155-024-00465-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:Viabahn 内支架已成为血管内治疗的重要选择,但有关其外周动脉瘤修复效果的长期数据却很有限。本研究旨在评估 Viabahn 内支架治疗股动脉瘤的安全性、技术和临床成功率以及长期通畅性:这项回顾性三级单中心研究分析了2010年至2020年间接受Viabahn内支架手术治疗股动脉瘤的患者。研究评估了术中并发症、技术和临床成功率以及30天后的主要不良事件(MAE,包括急性血栓性闭塞、主要截肢、心肌梗死以及与设备或手术相关的死亡)。临床驱动的靶病变血运重建(cdTLR)发生率也被记录在案。通过 Kaplan-Meier 分析评估了通畅率:在使用 Viabahn 内支架进行动脉瘤修复的 19 名患者(平均年龄 72 ± 12 岁;18 名男性,1 名女性)中,没有发生术中不良事件,技术和临床成功率均为 100%。30 天后,所有患者(19/19,100%)均无 MAE。中位随访时间为 1,009 天[IQR,462-1,466]。分别有 2/19 名患者(10.5%)在 27 个月和 45 个月后发生腘窝支架移植物闭塞。因此,在 12 个月、24 个月和 36-72 个月时,主要通畅率分别为 100%、90% 和 74%。两个病例的血管内 cdTLR 均获得成功,继发性通畅率达到 100%:结论:使用 Viabahn 内支架进行股腘动脉瘤修补术的技术和临床成功率均为 100%,30 天 MAE 率为 0%,长期通畅率非常高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Viabahn endoprosthesis for femoropopliteal aneurysm repair: safety, success rates, and long-term patency.

Background: The Viabahn endoprosthesis has become a vital option for endovascular therapy, yet there is limited long-term data on its effectiveness for peripheral aneurysm repair. This study aimed to evaluate the safety, technical and clinical success, and long-term patency of the Viabahn endoprosthesis for treating femoropopliteal aneurysms.

Methods: This retrospective tertiary single-center study analyzed patients who underwent a Viabahn endoprosthesis procedure for femoropopliteal aneurysm repair from 2010 to 2020. Intraoperative complications, technical and clinical success rates, and major adverse events (MAE, including acute thrombotic occlusion, major amputation, myocardial infarction, and device- or procedure-related death) at 30 days were assessed. Incidence of clinically-driven target lesion revascularisation (cdTLR) was noted. Patency rates were evaluated by Kaplan-Meier analysis.

Results: Among 19 patients (mean age, 72 ± 12 years; 18 male, 1 female) who underwent aneurysm repair using the Viabahn endoprosthesis, there were no intraoperative adverse events, with 100% technical and clinical success rates. At the 30-day mark, all patients (19/19, 100%) were free of MAE. The median follow-up duration was 1,009 days [IQR, 462-1,466]. Popliteal stent graft occlusion occurred in 2/19 patients (10.5%) after 27 and 45 months, respectively. Consequently, the primary patency rates were 100%, 90%, 74% at 12, 24, and 36-72 months, respectively. Endovascular cdTLR was successful in both cases, resulting in sustained secondary patency at 100%.

Conclusion: The use of Viabahn endoprostheses for femoropopliteal aneurysm repair demonstrated technical and clinical success rates of 100%, a 0% 30-day MAE rate, and excellent long-term patency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CVIR Endovascular
CVIR Endovascular Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.30
自引率
0.00%
发文量
59
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信