Kavisha Patel, Sandeep Toomu, Euyhyun Lee, Douglas Darden, Kathleen Jacobs, Travis Pollema, Gordon Ho, Ulrika Birgersdotter-Green
{"title":"计算机断层扫描预测经静脉引线取出难度增加的因素。","authors":"Kavisha Patel, Sandeep Toomu, Euyhyun Lee, Douglas Darden, Kathleen Jacobs, Travis Pollema, Gordon Ho, Ulrika Birgersdotter-Green","doi":"10.1111/pace.15034","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject.</p><p><strong>Objective: </strong>To identify CT characteristics associated with increased TLE difficulty.</p><p><strong>Methods: </strong>All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac-gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead-removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty.</p><p><strong>Results: </strong>A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell-in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead-removal fluoroscopy time (p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54-10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89-7.35), respectively.</p><p><strong>Conclusion: </strong>In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead-associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":" ","pages":"1232-1240"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computed tomography predictors of increased transvenous lead extraction difficulty.\",\"authors\":\"Kavisha Patel, Sandeep Toomu, Euyhyun Lee, Douglas Darden, Kathleen Jacobs, Travis Pollema, Gordon Ho, Ulrika Birgersdotter-Green\",\"doi\":\"10.1111/pace.15034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject.</p><p><strong>Objective: </strong>To identify CT characteristics associated with increased TLE difficulty.</p><p><strong>Methods: </strong>All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac-gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead-removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty.</p><p><strong>Results: </strong>A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell-in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead-removal fluoroscopy time (p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54-10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89-7.35), respectively.</p><p><strong>Conclusion: </strong>In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead-associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":\" \",\"pages\":\"1232-1240\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.15034\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15034","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Computed tomography predictors of increased transvenous lead extraction difficulty.
Background: The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject.
Objective: To identify CT characteristics associated with increased TLE difficulty.
Methods: All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac-gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead-removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty.
Results: A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell-in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead-removal fluoroscopy time (p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54-10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89-7.35), respectively.
Conclusion: In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead-associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.