血友病膝关节全膝关节置换术数字模板的准确性和临床作用

IF 3 2区 医学 Q2 HEMATOLOGY
Haemophilia Pub Date : 2024-06-20 DOI:10.1111/hae.15072
Arman Vahabi, Erdem Er, Elcil Kaya Biçer, Fahri Şahin, Kaan Kavakli, Semih Aydoğdu
{"title":"血友病膝关节全膝关节置换术数字模板的准确性和临床作用","authors":"Arman Vahabi,&nbsp;Erdem Er,&nbsp;Elcil Kaya Biçer,&nbsp;Fahri Şahin,&nbsp;Kaan Kavakli,&nbsp;Semih Aydoğdu","doi":"10.1111/hae.15072","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>In total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>TKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one-to-one matching regarding type of implant used. Intra- and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty-eight knees in each group included.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Regarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73–.98)], femur lateral [.98 (.91–.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74–.98)] and tibia AP templating [.90 (.65–.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70–.89), .86 (.77–.91), .79 (.67–.87) while femur AP templating showed moderate correlation [.67 (.50–.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating (<i>p</i> = .056, <i>p</i> = .781, <i>p</i> = .761, <i>p</i> = .083, respectively).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Although 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.</p>\n </section>\n </div>","PeriodicalId":12819,"journal":{"name":"Haemophilia","volume":"30 4","pages":"1043-1049"},"PeriodicalIF":3.0000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/hae.15072","citationCount":"0","resultStr":"{\"title\":\"Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees\",\"authors\":\"Arman Vahabi,&nbsp;Erdem Er,&nbsp;Elcil Kaya Biçer,&nbsp;Fahri Şahin,&nbsp;Kaan Kavakli,&nbsp;Semih Aydoğdu\",\"doi\":\"10.1111/hae.15072\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>In total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>TKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one-to-one matching regarding type of implant used. Intra- and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty-eight knees in each group included.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Regarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73–.98)], femur lateral [.98 (.91–.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74–.98)] and tibia AP templating [.90 (.65–.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70–.89), .86 (.77–.91), .79 (.67–.87) while femur AP templating showed moderate correlation [.67 (.50–.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating (<i>p</i> = .056, <i>p</i> = .781, <i>p</i> = .761, <i>p</i> = .083, respectively).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Although 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.</p>\\n </section>\\n </div>\",\"PeriodicalId\":12819,\"journal\":{\"name\":\"Haemophilia\",\"volume\":\"30 4\",\"pages\":\"1043-1049\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/hae.15072\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Haemophilia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/hae.15072\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Haemophilia","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/hae.15072","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言:在全膝关节置换术(TKA)中,选择正确的植入物尺寸非常重要。目前还缺乏有关嗜血膝关节模板制作准确性的数据。我们的目的是测试二维数字模板对嗜血细胞性膝关节病(HA)的 TKA 的准确性。骨关节炎(OA)组作为对照组,在所用植入物类型上进行一对一匹配。在HA组中测量观察者内部和观察者之间的相关性,然后在四项评估(股骨AP、股骨侧、胫骨AP、胫骨侧)中调查模板尺寸和植入尺寸之间的相关性,然后与OA组进行比较。结果关于HA的观察者内相关性,股骨AP[.93(.73-.98)]、股骨侧[.98(.91-.99)]和胫骨AP(1.0)模板的相关性极佳。在医管局的观察者间相关性方面,股骨外侧[.93(.74-.98)]和胫骨AP模板[.90(.65-.97)]的相关性极佳。关于HA中模板和应用尺寸的相关性,胫骨AP、胫骨外侧和股骨外侧模板显示出良好的相关性[.81(.70-.89)、.86(.77-.91)、.79(.67-.87)],而股骨AP模板显示出中等相关性[.67(.50-.79)]。结论虽然二维数字模板在HA和OA中显示出相似的相关性,但目前模板在HA中的临床应用似乎还很有限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees

Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees

Introduction

In total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee.

Materials and Methods

TKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one-to-one matching regarding type of implant used. Intra- and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty-eight knees in each group included.

Results

Regarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73–.98)], femur lateral [.98 (.91–.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74–.98)] and tibia AP templating [.90 (.65–.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70–.89), .86 (.77–.91), .79 (.67–.87) while femur AP templating showed moderate correlation [.67 (.50–.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating (p = .056, p = .781, p = .761, p = .083, respectively).

Conclusion

Although 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Haemophilia
Haemophilia 医学-血液学
CiteScore
6.50
自引率
28.20%
发文量
226
审稿时长
3-6 weeks
期刊介绍: Haemophilia is an international journal dedicated to the exchange of information regarding the comprehensive care of haemophilia. The Journal contains review articles, original scientific papers and case reports related to haemophilia care, with frequent supplements. Subjects covered include: clotting factor deficiencies, both inherited and acquired: haemophilia A, B, von Willebrand''s disease, deficiencies of factor V, VII, X and XI replacement therapy for clotting factor deficiencies component therapy in the developing world transfusion transmitted disease haemophilia care and paediatrics, orthopaedics, gynaecology and obstetrics nursing laboratory diagnosis carrier detection psycho-social concerns economic issues audit inherited platelet disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信