用于输电线路异常对象检测的高能效和低位宽浮点型数据研究

IF 1.9 Q4 ENERGY & FUELS
Chen Wang , Guozheng Peng , Rui Song , Jun Zhang , Li Yan
{"title":"用于输电线路异常对象检测的高能效和低位宽浮点型数据研究","authors":"Chen Wang ,&nbsp;Guozheng Peng ,&nbsp;Rui Song ,&nbsp;Jun Zhang ,&nbsp;Li Yan","doi":"10.1016/j.gloei.2024.06.009","DOIUrl":null,"url":null,"abstract":"<div><p>Achieving a balance between accuracy and efficiency in target detection applications is an important research topic. To detect abnormal targets on power transmission lines at the power edge, this paper proposes an effective method for reducing the data bit width of the network for floating-point quantization. By performing exponent prealignment and mantissa shifting operations, this method avoids the frequent alignment operations of standard floating-point data, thereby further reducing the exponent and mantissa bit width input into the training process. This enables training low-data-bit width models with low hardware-resource consumption while maintaining accuracy. Experimental tests were conducted on a dataset of real-world images of abnormal targets on transmission lines. The results indicate that while maintaining accuracy at a basic level, the proposed method can significantly reduce the data bit width compared with single-precision data. This suggests that the proposed method has a marked ability to enhance the real-time detection of abnormal targets in transmission circuits. Furthermore, a qualitative analysis indicated that the proposed quantization method is particularly suitable for hardware architectures that integrate storage and computation and exhibit good transferability.</p></div>","PeriodicalId":36174,"journal":{"name":"Global Energy Interconnection","volume":"7 3","pages":"Pages 324-335"},"PeriodicalIF":1.9000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2096511724000483/pdf?md5=06b70b07c50e324a90a107045aa01e60&pid=1-s2.0-S2096511724000483-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Research on high energy efficiency and low bit-width floating-point type data for abnormal object detection of transmission lines\",\"authors\":\"Chen Wang ,&nbsp;Guozheng Peng ,&nbsp;Rui Song ,&nbsp;Jun Zhang ,&nbsp;Li Yan\",\"doi\":\"10.1016/j.gloei.2024.06.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Achieving a balance between accuracy and efficiency in target detection applications is an important research topic. To detect abnormal targets on power transmission lines at the power edge, this paper proposes an effective method for reducing the data bit width of the network for floating-point quantization. By performing exponent prealignment and mantissa shifting operations, this method avoids the frequent alignment operations of standard floating-point data, thereby further reducing the exponent and mantissa bit width input into the training process. This enables training low-data-bit width models with low hardware-resource consumption while maintaining accuracy. Experimental tests were conducted on a dataset of real-world images of abnormal targets on transmission lines. The results indicate that while maintaining accuracy at a basic level, the proposed method can significantly reduce the data bit width compared with single-precision data. This suggests that the proposed method has a marked ability to enhance the real-time detection of abnormal targets in transmission circuits. Furthermore, a qualitative analysis indicated that the proposed quantization method is particularly suitable for hardware architectures that integrate storage and computation and exhibit good transferability.</p></div>\",\"PeriodicalId\":36174,\"journal\":{\"name\":\"Global Energy Interconnection\",\"volume\":\"7 3\",\"pages\":\"Pages 324-335\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2096511724000483/pdf?md5=06b70b07c50e324a90a107045aa01e60&pid=1-s2.0-S2096511724000483-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Energy Interconnection\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2096511724000483\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Energy Interconnection","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2096511724000483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

在目标检测应用中实现准确性和效率之间的平衡是一个重要的研究课题。为了检测输电线路上功率边缘的异常目标,本文提出了一种有效的方法来减少浮点量化网络的数据位宽。该方法通过执行指数预对齐和尾数移位操作,避免了标准浮点数据的频繁对齐操作,从而进一步降低了输入到训练过程中的指数和尾数位宽。这样就能在保持精度的同时,以较低的硬件资源消耗训练低数据位宽的模型。实验测试在输电线上异常目标的真实世界图像数据集上进行。结果表明,在保持基本精度的同时,与单精度数据相比,所提出的方法可以显著降低数据位宽。这表明,所提出的方法在提高输电线路异常目标的实时检测能力方面具有明显的优势。此外,定性分析表明,所提出的量化方法特别适用于集成了存储和计算的硬件架构,并表现出良好的可移植性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on high energy efficiency and low bit-width floating-point type data for abnormal object detection of transmission lines

Achieving a balance between accuracy and efficiency in target detection applications is an important research topic. To detect abnormal targets on power transmission lines at the power edge, this paper proposes an effective method for reducing the data bit width of the network for floating-point quantization. By performing exponent prealignment and mantissa shifting operations, this method avoids the frequent alignment operations of standard floating-point data, thereby further reducing the exponent and mantissa bit width input into the training process. This enables training low-data-bit width models with low hardware-resource consumption while maintaining accuracy. Experimental tests were conducted on a dataset of real-world images of abnormal targets on transmission lines. The results indicate that while maintaining accuracy at a basic level, the proposed method can significantly reduce the data bit width compared with single-precision data. This suggests that the proposed method has a marked ability to enhance the real-time detection of abnormal targets in transmission circuits. Furthermore, a qualitative analysis indicated that the proposed quantization method is particularly suitable for hardware architectures that integrate storage and computation and exhibit good transferability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Global Energy Interconnection
Global Energy Interconnection Engineering-Automotive Engineering
CiteScore
5.70
自引率
0.00%
发文量
985
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信