Alexa J Karkenny, Allyn Morris, Cameron Smith, Jorden Xavier, Zeynep Seref-Ferlengez, Leila Mehraban Alvandi, I Martin Levy
{"title":"双壳铸件的外包装:材料重要吗?","authors":"Alexa J Karkenny, Allyn Morris, Cameron Smith, Jorden Xavier, Zeynep Seref-Ferlengez, Leila Mehraban Alvandi, I Martin Levy","doi":"10.1097/BPO.0000000000002751","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Circumferential integrity of bivalved casts (cut twice longitudinally) can be restored by overwrapping with different materials. This study compared the mechanical properties of solid casts and bivalved casts overwrapped with semirigid fiberglass (SF), elastic bandages (EB), and rigid fiberglass (RF) using an overwrapped-bivalved cast-bone fracture (OBCBF) model.</p><p><strong>Methods: </strong>This study used an MTS Bionix Servohydraulic system to test properties of OBCBF models in 4 conditions: intact Control made of RF (not bivalved or overwrapped), a Rigid overwrapped model made of a Control bivalved and overwrapped with RF, a Semirigid overwrapped model made of a Control bivalved and overwrapped with SF, and an Elastic model made of a Control bivalved and overwrapped with EB. Constructs were tested in 4-point bending. Force-displacement curves (FDC) were generated to calculate load-at-critical-failure (LCF, angulation > 10 degrees = 6.6 mm vertical deformation) and stiffness.</p><p><strong>Results: </strong>Five controls and 30 OBCBF models with 3 overwrapped cast types were tested, with each overwrapped cast type tested with 2 orientations of the initial cast bivalve axis, yielding 7 conditions (Control, Rigid 0 degrees, Rigid 90 degrees, Semirigid 0 degrees, Semirigid 90 degrees, Elastic 0 degrees, Elastic 90 degrees). Mean LCF was: Rigid 90 degrees > Rigid 0 degrees > Control > Semirigid 0 degrees > Semirigid 90 degrees > Elastic 90 degrees > Elastic 0 degrees ( P <0.0001). Mean stiffness was: Rigid 0 degrees > Rigid 90 degrees > Control > Semirigid 90 degrees > Semirigid 0 degrees > Elastic 0 degrees > Elastic 90 degrees ( P <0.0001). Multiple comparisons indicated no significant difference between LCF and stiffness for Semirigid 0 degrees/90 degrees casts compared with Controls.</p><p><strong>Conclusions: </strong>Mechanical properties of overwrapped bivalved casts change depending on the materials used to overwrap, with higher LCF and stiffness when overwrapping with RF > SF > EB; however, mean comparisons indicate that rigid bivalved casts overwrapped with SF did not have significantly different mean stiffness and LCF from controls and other cast models.</p><p><strong>Clinical relevance: </strong>This study compares the bending properties of a bivalved cast-construct overwrapped with different materials, providing basic science evidence for orthopaedic surgeons who have several choices of materials to overwrap bivalved casts.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Overwrapping Bivalved Casts: Does the Material Matter?\",\"authors\":\"Alexa J Karkenny, Allyn Morris, Cameron Smith, Jorden Xavier, Zeynep Seref-Ferlengez, Leila Mehraban Alvandi, I Martin Levy\",\"doi\":\"10.1097/BPO.0000000000002751\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Circumferential integrity of bivalved casts (cut twice longitudinally) can be restored by overwrapping with different materials. This study compared the mechanical properties of solid casts and bivalved casts overwrapped with semirigid fiberglass (SF), elastic bandages (EB), and rigid fiberglass (RF) using an overwrapped-bivalved cast-bone fracture (OBCBF) model.</p><p><strong>Methods: </strong>This study used an MTS Bionix Servohydraulic system to test properties of OBCBF models in 4 conditions: intact Control made of RF (not bivalved or overwrapped), a Rigid overwrapped model made of a Control bivalved and overwrapped with RF, a Semirigid overwrapped model made of a Control bivalved and overwrapped with SF, and an Elastic model made of a Control bivalved and overwrapped with EB. Constructs were tested in 4-point bending. Force-displacement curves (FDC) were generated to calculate load-at-critical-failure (LCF, angulation > 10 degrees = 6.6 mm vertical deformation) and stiffness.</p><p><strong>Results: </strong>Five controls and 30 OBCBF models with 3 overwrapped cast types were tested, with each overwrapped cast type tested with 2 orientations of the initial cast bivalve axis, yielding 7 conditions (Control, Rigid 0 degrees, Rigid 90 degrees, Semirigid 0 degrees, Semirigid 90 degrees, Elastic 0 degrees, Elastic 90 degrees). Mean LCF was: Rigid 90 degrees > Rigid 0 degrees > Control > Semirigid 0 degrees > Semirigid 90 degrees > Elastic 90 degrees > Elastic 0 degrees ( P <0.0001). Mean stiffness was: Rigid 0 degrees > Rigid 90 degrees > Control > Semirigid 90 degrees > Semirigid 0 degrees > Elastic 0 degrees > Elastic 90 degrees ( P <0.0001). Multiple comparisons indicated no significant difference between LCF and stiffness for Semirigid 0 degrees/90 degrees casts compared with Controls.</p><p><strong>Conclusions: </strong>Mechanical properties of overwrapped bivalved casts change depending on the materials used to overwrap, with higher LCF and stiffness when overwrapping with RF > SF > EB; however, mean comparisons indicate that rigid bivalved casts overwrapped with SF did not have significantly different mean stiffness and LCF from controls and other cast models.</p><p><strong>Clinical relevance: </strong>This study compares the bending properties of a bivalved cast-construct overwrapped with different materials, providing basic science evidence for orthopaedic surgeons who have several choices of materials to overwrap bivalved casts.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/BPO.0000000000002751\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPO.0000000000002751","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Overwrapping Bivalved Casts: Does the Material Matter?
Background: Circumferential integrity of bivalved casts (cut twice longitudinally) can be restored by overwrapping with different materials. This study compared the mechanical properties of solid casts and bivalved casts overwrapped with semirigid fiberglass (SF), elastic bandages (EB), and rigid fiberglass (RF) using an overwrapped-bivalved cast-bone fracture (OBCBF) model.
Methods: This study used an MTS Bionix Servohydraulic system to test properties of OBCBF models in 4 conditions: intact Control made of RF (not bivalved or overwrapped), a Rigid overwrapped model made of a Control bivalved and overwrapped with RF, a Semirigid overwrapped model made of a Control bivalved and overwrapped with SF, and an Elastic model made of a Control bivalved and overwrapped with EB. Constructs were tested in 4-point bending. Force-displacement curves (FDC) were generated to calculate load-at-critical-failure (LCF, angulation > 10 degrees = 6.6 mm vertical deformation) and stiffness.
Results: Five controls and 30 OBCBF models with 3 overwrapped cast types were tested, with each overwrapped cast type tested with 2 orientations of the initial cast bivalve axis, yielding 7 conditions (Control, Rigid 0 degrees, Rigid 90 degrees, Semirigid 0 degrees, Semirigid 90 degrees, Elastic 0 degrees, Elastic 90 degrees). Mean LCF was: Rigid 90 degrees > Rigid 0 degrees > Control > Semirigid 0 degrees > Semirigid 90 degrees > Elastic 90 degrees > Elastic 0 degrees ( P <0.0001). Mean stiffness was: Rigid 0 degrees > Rigid 90 degrees > Control > Semirigid 90 degrees > Semirigid 0 degrees > Elastic 0 degrees > Elastic 90 degrees ( P <0.0001). Multiple comparisons indicated no significant difference between LCF and stiffness for Semirigid 0 degrees/90 degrees casts compared with Controls.
Conclusions: Mechanical properties of overwrapped bivalved casts change depending on the materials used to overwrap, with higher LCF and stiffness when overwrapping with RF > SF > EB; however, mean comparisons indicate that rigid bivalved casts overwrapped with SF did not have significantly different mean stiffness and LCF from controls and other cast models.
Clinical relevance: This study compares the bending properties of a bivalved cast-construct overwrapped with different materials, providing basic science evidence for orthopaedic surgeons who have several choices of materials to overwrap bivalved casts.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.