{"title":"利用化学电离质谱法测量新泽西州中部空气中的短链全氟和多氟烷基物质。","authors":"James M Mattila, John H Offenberg","doi":"10.1080/10962247.2024.2366491","DOIUrl":null,"url":null,"abstract":"<p><p>Real-time measurements of short-chain (C < 8) per- and polyfluoroalkyl substances (PFAS) were performed in Central New Jersey air using chemical ionization mass spectrometry (CIMS). The CIMS was calibrated for C<sub>2</sub>-C<sub>6</sub> perfluorinated carboxylic acids, and 4:2 and 6:2 fluorotelomer alcohols. Of these, only trifluoroacetic acid (TFA) was detected in ambient air above instrumental detection limits. However, instrumental sensitivities (and thus ambient mixing ratios) were estimated for other detected PFAS including C<sub>3</sub>H<sub>2</sub>F<sub>6</sub>O and C<sub>6</sub>HF<sub>11</sub>O<sub>3</sub>. TFA mixing ratios reached up to 0.7 parts-per-trillion by volume (pptv). Estimated C<sub>3</sub>H<sub>2</sub>F<sub>6</sub>O and C<sub>6</sub>HF<sub>11</sub>O<sub>3</sub> mixing ratios reached the single pptv level. These latter two formulas are consistent with hexafluoroisopropanol (HFIP) and hexafluoropropylene oxide dimer acid (HFPO-DA), respectively, though they may potentially represent multiple isomers. Diel profiles of detected PFAS along with local meteorological data can provide information on potential local sources of these compounds. However, only limited discussion of potential sources was provided here given the sparse detection of these compounds above instrument detection limits. These results demonstrate the potential of online CIMS instrumentation for measuring certain PFAS in ambient outdoor air in real time at or below the pptv level. This technique also has potential for fenceline monitoring and other near-source applications.<i>Implications</i>: Online chemical ionization mass spectrometry (CIMS) has potential for fast, real-time measurements of certain airborne per- and polyfluoroalkyl substances (PFAS). Three short-chain (C < 8) PFAS were detected by CIMS in Central New Jersey ambient air near or above the parts-per-trillion by volume (pptv) level. This technique also has potential for fenceline monitoring and other near-source applications for airborne PFAS.</p>","PeriodicalId":49171,"journal":{"name":"Journal of the Air & Waste Management Association","volume":" ","pages":"531-539"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11412083/pdf/","citationCount":"0","resultStr":"{\"title\":\"Measuring short-chain per- and polyfluoroalkyl substances in Central New Jersey air using chemical ionization mass spectrometry.\",\"authors\":\"James M Mattila, John H Offenberg\",\"doi\":\"10.1080/10962247.2024.2366491\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Real-time measurements of short-chain (C < 8) per- and polyfluoroalkyl substances (PFAS) were performed in Central New Jersey air using chemical ionization mass spectrometry (CIMS). The CIMS was calibrated for C<sub>2</sub>-C<sub>6</sub> perfluorinated carboxylic acids, and 4:2 and 6:2 fluorotelomer alcohols. Of these, only trifluoroacetic acid (TFA) was detected in ambient air above instrumental detection limits. However, instrumental sensitivities (and thus ambient mixing ratios) were estimated for other detected PFAS including C<sub>3</sub>H<sub>2</sub>F<sub>6</sub>O and C<sub>6</sub>HF<sub>11</sub>O<sub>3</sub>. TFA mixing ratios reached up to 0.7 parts-per-trillion by volume (pptv). Estimated C<sub>3</sub>H<sub>2</sub>F<sub>6</sub>O and C<sub>6</sub>HF<sub>11</sub>O<sub>3</sub> mixing ratios reached the single pptv level. These latter two formulas are consistent with hexafluoroisopropanol (HFIP) and hexafluoropropylene oxide dimer acid (HFPO-DA), respectively, though they may potentially represent multiple isomers. Diel profiles of detected PFAS along with local meteorological data can provide information on potential local sources of these compounds. However, only limited discussion of potential sources was provided here given the sparse detection of these compounds above instrument detection limits. These results demonstrate the potential of online CIMS instrumentation for measuring certain PFAS in ambient outdoor air in real time at or below the pptv level. This technique also has potential for fenceline monitoring and other near-source applications.<i>Implications</i>: Online chemical ionization mass spectrometry (CIMS) has potential for fast, real-time measurements of certain airborne per- and polyfluoroalkyl substances (PFAS). Three short-chain (C < 8) PFAS were detected by CIMS in Central New Jersey ambient air near or above the parts-per-trillion by volume (pptv) level. This technique also has potential for fenceline monitoring and other near-source applications for airborne PFAS.</p>\",\"PeriodicalId\":49171,\"journal\":{\"name\":\"Journal of the Air & Waste Management Association\",\"volume\":\" \",\"pages\":\"531-539\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11412083/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Air & Waste Management Association\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1080/10962247.2024.2366491\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air & Waste Management Association","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/10962247.2024.2366491","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
Measuring short-chain per- and polyfluoroalkyl substances in Central New Jersey air using chemical ionization mass spectrometry.
Real-time measurements of short-chain (C < 8) per- and polyfluoroalkyl substances (PFAS) were performed in Central New Jersey air using chemical ionization mass spectrometry (CIMS). The CIMS was calibrated for C2-C6 perfluorinated carboxylic acids, and 4:2 and 6:2 fluorotelomer alcohols. Of these, only trifluoroacetic acid (TFA) was detected in ambient air above instrumental detection limits. However, instrumental sensitivities (and thus ambient mixing ratios) were estimated for other detected PFAS including C3H2F6O and C6HF11O3. TFA mixing ratios reached up to 0.7 parts-per-trillion by volume (pptv). Estimated C3H2F6O and C6HF11O3 mixing ratios reached the single pptv level. These latter two formulas are consistent with hexafluoroisopropanol (HFIP) and hexafluoropropylene oxide dimer acid (HFPO-DA), respectively, though they may potentially represent multiple isomers. Diel profiles of detected PFAS along with local meteorological data can provide information on potential local sources of these compounds. However, only limited discussion of potential sources was provided here given the sparse detection of these compounds above instrument detection limits. These results demonstrate the potential of online CIMS instrumentation for measuring certain PFAS in ambient outdoor air in real time at or below the pptv level. This technique also has potential for fenceline monitoring and other near-source applications.Implications: Online chemical ionization mass spectrometry (CIMS) has potential for fast, real-time measurements of certain airborne per- and polyfluoroalkyl substances (PFAS). Three short-chain (C < 8) PFAS were detected by CIMS in Central New Jersey ambient air near or above the parts-per-trillion by volume (pptv) level. This technique also has potential for fenceline monitoring and other near-source applications for airborne PFAS.
期刊介绍:
The Journal of the Air & Waste Management Association (J&AWMA) is one of the oldest continuously published, peer-reviewed, technical environmental journals in the world. First published in 1951 under the name Air Repair, J&AWMA is intended to serve those occupationally involved in air pollution control and waste management through the publication of timely and reliable information.