{"title":"使用 P、PI 和 PID 控制器调节多槽水平通道中的混合对流","authors":"Sonjoy Chandra Debnath, Shuvo Chowdhury, Md Asaduzzaman, Most. Naznin Nahar, Ankita Binte Sattar, Sumon Saha","doi":"10.1049/tje2.12401","DOIUrl":null,"url":null,"abstract":"This study numerically investigates mixed convective cooling in a two‐dimensional horizontal channel containing periodically heated blocks by applying proportional (P), proportional‐integral (PI), and proportional‐integral‐derivative (PID) controllers. Three different controller configurations regulate the amount of cold air entering the chamber. The air's non‐dimensional temperature is continuously monitored at the set point to compare the controllers’ performance, and the percentage of overshoot and the steady‐state error are analysed. The investigated chamber comprises one inlet and two exit ports, a temperature sensor, and two heated blocks that are isotherm heat sources. The Galerkin finite element approach computationally solves the equations of continuity, momentum, and energy to analyse the thermo‐fluid phenomena occurring within the chamber. Parametric simulation is carried for different values of the proportional gain (Kp = 0.005, 0.010, 0.050 m s−1 K−1), the integral gain (Ki = 0.05, 0.10, 0.15 m s−2 K−1), the derivative gain (Kd = 10−5, 10−4, 10−3 m K−1) to achieve a consistent and expeditious response. Variations of Reynolds, Richardson, and mean Nusselt numbers with time are plotted to compare the system's performance. The investigation indicates that the PI controller produces a comparable level of performance with the PID controller, reducing the necessity to add a derivative controller.","PeriodicalId":22858,"journal":{"name":"The Journal of Engineering","volume":"177 S430","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Regulation of mixed convective flow in a horizontal channel with multiple slots using P, PI, and PID controllers\",\"authors\":\"Sonjoy Chandra Debnath, Shuvo Chowdhury, Md Asaduzzaman, Most. Naznin Nahar, Ankita Binte Sattar, Sumon Saha\",\"doi\":\"10.1049/tje2.12401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study numerically investigates mixed convective cooling in a two‐dimensional horizontal channel containing periodically heated blocks by applying proportional (P), proportional‐integral (PI), and proportional‐integral‐derivative (PID) controllers. Three different controller configurations regulate the amount of cold air entering the chamber. The air's non‐dimensional temperature is continuously monitored at the set point to compare the controllers’ performance, and the percentage of overshoot and the steady‐state error are analysed. The investigated chamber comprises one inlet and two exit ports, a temperature sensor, and two heated blocks that are isotherm heat sources. The Galerkin finite element approach computationally solves the equations of continuity, momentum, and energy to analyse the thermo‐fluid phenomena occurring within the chamber. Parametric simulation is carried for different values of the proportional gain (Kp = 0.005, 0.010, 0.050 m s−1 K−1), the integral gain (Ki = 0.05, 0.10, 0.15 m s−2 K−1), the derivative gain (Kd = 10−5, 10−4, 10−3 m K−1) to achieve a consistent and expeditious response. Variations of Reynolds, Richardson, and mean Nusselt numbers with time are plotted to compare the system's performance. The investigation indicates that the PI controller produces a comparable level of performance with the PID controller, reducing the necessity to add a derivative controller.\",\"PeriodicalId\":22858,\"journal\":{\"name\":\"The Journal of Engineering\",\"volume\":\"177 S430\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/tje2.12401\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/tje2.12401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究采用比例 (P)、比例积分 (PI) 和比例积分派生 (PID) 控制器,对包含周期性加热块的二维水平通道中的混合对流冷却进行了数值研究。三种不同的控制器配置可调节进入腔室的冷空气量。在设定点连续监测空气的非尺寸温度,以比较控制器的性能,并分析过冲百分比和稳态误差。所研究的腔室包括一个入口和两个出口、一个温度传感器和两个等温热源加热块。Galerkin 有限元方法通过计算求解连续性、动量和能量方程来分析腔体内发生的热流体现象。针对不同的比例增益值(Kp = 0.005、0.010、0.050 m s-1 K-1)、积分增益值(Ki = 0.05、0.10、0.15 m s-2 K-1)和导数增益值(Kd = 10-5、10-4、10-3 m K-1)进行了参数模拟,以获得一致且快速的响应。绘制了雷诺数、理查森数和平均努塞尔特数随时间的变化曲线,以比较系统的性能。调查表明,PI 控制器的性能与 PID 控制器相当,从而减少了添加导数控制器的必要性。
Regulation of mixed convective flow in a horizontal channel with multiple slots using P, PI, and PID controllers
This study numerically investigates mixed convective cooling in a two‐dimensional horizontal channel containing periodically heated blocks by applying proportional (P), proportional‐integral (PI), and proportional‐integral‐derivative (PID) controllers. Three different controller configurations regulate the amount of cold air entering the chamber. The air's non‐dimensional temperature is continuously monitored at the set point to compare the controllers’ performance, and the percentage of overshoot and the steady‐state error are analysed. The investigated chamber comprises one inlet and two exit ports, a temperature sensor, and two heated blocks that are isotherm heat sources. The Galerkin finite element approach computationally solves the equations of continuity, momentum, and energy to analyse the thermo‐fluid phenomena occurring within the chamber. Parametric simulation is carried for different values of the proportional gain (Kp = 0.005, 0.010, 0.050 m s−1 K−1), the integral gain (Ki = 0.05, 0.10, 0.15 m s−2 K−1), the derivative gain (Kd = 10−5, 10−4, 10−3 m K−1) to achieve a consistent and expeditious response. Variations of Reynolds, Richardson, and mean Nusselt numbers with time are plotted to compare the system's performance. The investigation indicates that the PI controller produces a comparable level of performance with the PID controller, reducing the necessity to add a derivative controller.