应用宽带电流传感器评估 IEC 61000-3-2(12)标准要求的准确性

E. Stano, S. Wiak
{"title":"应用宽带电流传感器评估 IEC 61000-3-2(12)标准要求的准确性","authors":"E. Stano, S. Wiak","doi":"10.3390/s24113693","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to determine the conversion accuracy of the Danisense DC200IF (Danisense A/S, Taastrup, Denmark) wideband current transducer for its possible application to test electromagnetic compatibility requirements of the standards IEC 61000-3-2 and IEC 61000-3-12 with the digital power meter Yokogawa WT5000 (Yokogawa Electric Corporation, Tokyo, Japan). To obtain this goal for distorted current of main frequency equal to 50 Hz and in the frequencies range of higher harmonics from 100 Hz to 2500 Hz its amplitude error and phase shift are evaluated. Moreover, the measurable level of higher harmonics with the rated accuracy of the used precision power analyzer is also investigated. Finally, the measuring system is applied to determine the RMS values of current harmonics produced by the audio power amplifier in order to assess its compliance with the standard IEC 61000-3-12.","PeriodicalId":221960,"journal":{"name":"Sensors (Basel, Switzerland)","volume":"39 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Accuracy of Evaluation of the Requirements of the Standards IEC 61000-3-2(12) with the Application of the Wideband Current Transducer\",\"authors\":\"E. Stano, S. Wiak\",\"doi\":\"10.3390/s24113693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this paper is to determine the conversion accuracy of the Danisense DC200IF (Danisense A/S, Taastrup, Denmark) wideband current transducer for its possible application to test electromagnetic compatibility requirements of the standards IEC 61000-3-2 and IEC 61000-3-12 with the digital power meter Yokogawa WT5000 (Yokogawa Electric Corporation, Tokyo, Japan). To obtain this goal for distorted current of main frequency equal to 50 Hz and in the frequencies range of higher harmonics from 100 Hz to 2500 Hz its amplitude error and phase shift are evaluated. Moreover, the measurable level of higher harmonics with the rated accuracy of the used precision power analyzer is also investigated. Finally, the measuring system is applied to determine the RMS values of current harmonics produced by the audio power amplifier in order to assess its compliance with the standard IEC 61000-3-12.\",\"PeriodicalId\":221960,\"journal\":{\"name\":\"Sensors (Basel, Switzerland)\",\"volume\":\"39 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors (Basel, Switzerland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/s24113693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/s24113693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文旨在确定 Danisense DC200IF(Danisense A/S, Taastrup, Denmark)宽带电流传感器的转换精度,以便将其与数字功率计 Yokogawa WT5000(Yokogawa Electric Corporation, Tokyo, Japan)配合使用,测试 IEC 61000-3-2 和 IEC 61000-3-12 标准的电磁兼容性要求。为了实现这一目标,对主频等于 50 Hz 的畸变电流以及 100 Hz 至 2500 Hz 高次谐波频率范围内的幅值误差和相移进行了评估。此外,还研究了高次谐波在所用精密功率分析仪额定精度下的可测量水平。最后,测量系统被用于确定音频功率放大器产生的电流谐波有效值,以评估其是否符合 IEC 61000-3-12 标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Accuracy of Evaluation of the Requirements of the Standards IEC 61000-3-2(12) with the Application of the Wideband Current Transducer
The aim of this paper is to determine the conversion accuracy of the Danisense DC200IF (Danisense A/S, Taastrup, Denmark) wideband current transducer for its possible application to test electromagnetic compatibility requirements of the standards IEC 61000-3-2 and IEC 61000-3-12 with the digital power meter Yokogawa WT5000 (Yokogawa Electric Corporation, Tokyo, Japan). To obtain this goal for distorted current of main frequency equal to 50 Hz and in the frequencies range of higher harmonics from 100 Hz to 2500 Hz its amplitude error and phase shift are evaluated. Moreover, the measurable level of higher harmonics with the rated accuracy of the used precision power analyzer is also investigated. Finally, the measuring system is applied to determine the RMS values of current harmonics produced by the audio power amplifier in order to assess its compliance with the standard IEC 61000-3-12.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信