用于工业物联网数据共享的基于协议的非侵入式 Modbus 监控设备

Xuanzhi Huang, Deji Chen, Hongyuan Hu
{"title":"用于工业物联网数据共享的基于协议的非侵入式 Modbus 监控设备","authors":"Xuanzhi Huang, Deji Chen, Hongyuan Hu","doi":"10.1117/12.3032042","DOIUrl":null,"url":null,"abstract":"The traditional Modbus communication architecture usually consists of a single master station and multiple slave stations, which can lead to decreased communication efficiency in certain application scenarios. As IIoT (Industrial Internet of Things) continues to progress, there is a growing demand for new sophisticated applications that necessitate retrieving data from various industrial settings. As a result, multi-master station technology has been developed, enabling the retrieval of on-site data without disrupting the data collection process of the primary master station. However, most of these solutions require modifications to the original bus and the suspension of the original data collection process during installation. In order to maintain the integrity of the original bus system, this study introduces a Modbus multi-master technology in which the additional master employs a non-invasive listening approach to receive messages. It identifies request and response messages based on the protocol’s function codes and message byte numbers, parses information, and shares the acquired data to IIoT applications. The technology was tested in an IIoT application in which a WirelessHART network node was converted into such a master, which uploads acquired data wirelessly to the IIoT application. The findings indicate that the new master successfully identified messages and exchanged data with precision","PeriodicalId":342847,"journal":{"name":"International Conference on Algorithms, Microchips and Network Applications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Protocol-based non-invasive Modbus monitoring device for industrial internet of things data sharing\",\"authors\":\"Xuanzhi Huang, Deji Chen, Hongyuan Hu\",\"doi\":\"10.1117/12.3032042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The traditional Modbus communication architecture usually consists of a single master station and multiple slave stations, which can lead to decreased communication efficiency in certain application scenarios. As IIoT (Industrial Internet of Things) continues to progress, there is a growing demand for new sophisticated applications that necessitate retrieving data from various industrial settings. As a result, multi-master station technology has been developed, enabling the retrieval of on-site data without disrupting the data collection process of the primary master station. However, most of these solutions require modifications to the original bus and the suspension of the original data collection process during installation. In order to maintain the integrity of the original bus system, this study introduces a Modbus multi-master technology in which the additional master employs a non-invasive listening approach to receive messages. It identifies request and response messages based on the protocol’s function codes and message byte numbers, parses information, and shares the acquired data to IIoT applications. The technology was tested in an IIoT application in which a WirelessHART network node was converted into such a master, which uploads acquired data wirelessly to the IIoT application. The findings indicate that the new master successfully identified messages and exchanged data with precision\",\"PeriodicalId\":342847,\"journal\":{\"name\":\"International Conference on Algorithms, Microchips and Network Applications\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Algorithms, Microchips and Network Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.3032042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Algorithms, Microchips and Network Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3032042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

传统的 Modbus 通信架构通常由一个主站和多个从站组成,在某些应用场景中会降低通信效率。随着 IIoT(工业物联网)的不断发展,对新的复杂应用的需求日益增长,这些应用需要从各种工业环境中检索数据。因此,多主站技术应运而生,能够在不中断主站数据收集过程的情况下检索现场数据。然而,这些解决方案大多需要修改原始总线,并在安装过程中暂停原始数据收集过程。为了保持原有总线系统的完整性,本研究引入了一种 Modbus 多主站技术,其中附加主站采用非侵入式监听方法接收信息。它根据协议的功能代码和信息字节编号识别请求和响应信息,解析信息,并将获取的数据共享给 IIoT 应用程序。该技术在一个 IIoT 应用中进行了测试,测试中,一个 WirelessHART 网络节点被转换成这样一个主站,通过无线方式将获取的数据上传到 IIoT 应用。测试结果表明,新的主站成功地识别了信息,并精确地交换了数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Protocol-based non-invasive Modbus monitoring device for industrial internet of things data sharing
The traditional Modbus communication architecture usually consists of a single master station and multiple slave stations, which can lead to decreased communication efficiency in certain application scenarios. As IIoT (Industrial Internet of Things) continues to progress, there is a growing demand for new sophisticated applications that necessitate retrieving data from various industrial settings. As a result, multi-master station technology has been developed, enabling the retrieval of on-site data without disrupting the data collection process of the primary master station. However, most of these solutions require modifications to the original bus and the suspension of the original data collection process during installation. In order to maintain the integrity of the original bus system, this study introduces a Modbus multi-master technology in which the additional master employs a non-invasive listening approach to receive messages. It identifies request and response messages based on the protocol’s function codes and message byte numbers, parses information, and shares the acquired data to IIoT applications. The technology was tested in an IIoT application in which a WirelessHART network node was converted into such a master, which uploads acquired data wirelessly to the IIoT application. The findings indicate that the new master successfully identified messages and exchanged data with precision
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信