通过融合雷达和光学图像探测多目标生命体征

Chao Wang, Xinfeng Hu, Xiaodong Yang, Wuliang Chang, Guangze Cao
{"title":"通过融合雷达和光学图像探测多目标生命体征","authors":"Chao Wang, Xinfeng Hu, Xiaodong Yang, Wuliang Chang, Guangze Cao","doi":"10.1117/12.3032020","DOIUrl":null,"url":null,"abstract":"Microwave radar has wide applications in the field of vital sign detection, but there are still some challenges in detecting multiple people in complex environments. For this problem, in this article, a multi-target vital signs detection system based on the fusion of radar and optical image is proposed. This system employs a fusion algorithm to enhance the speed and precision of detection. By comparing the measured data with the reference signal, it can be considered that the measured data has a certain accuracy. The average absolute error in heart rate (HR) detection was 4 beats per minute (BPM), while respiratory rate (RR) detection exhibited an error of 0.75 respirations per minute (RPM). The accuracy of heart rate detection stood at 91.61%, while respiratory rate detection accuracy attained 99.01%.","PeriodicalId":342847,"journal":{"name":"International Conference on Algorithms, Microchips and Network Applications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-target vital signs detection by fusing radar and optical images\",\"authors\":\"Chao Wang, Xinfeng Hu, Xiaodong Yang, Wuliang Chang, Guangze Cao\",\"doi\":\"10.1117/12.3032020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microwave radar has wide applications in the field of vital sign detection, but there are still some challenges in detecting multiple people in complex environments. For this problem, in this article, a multi-target vital signs detection system based on the fusion of radar and optical image is proposed. This system employs a fusion algorithm to enhance the speed and precision of detection. By comparing the measured data with the reference signal, it can be considered that the measured data has a certain accuracy. The average absolute error in heart rate (HR) detection was 4 beats per minute (BPM), while respiratory rate (RR) detection exhibited an error of 0.75 respirations per minute (RPM). The accuracy of heart rate detection stood at 91.61%, while respiratory rate detection accuracy attained 99.01%.\",\"PeriodicalId\":342847,\"journal\":{\"name\":\"International Conference on Algorithms, Microchips and Network Applications\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Algorithms, Microchips and Network Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.3032020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Algorithms, Microchips and Network Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3032020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

微波雷达在生命体征检测领域有着广泛的应用,但在复杂环境中检测多人时仍面临一些挑战。针对这一问题,本文提出了一种基于雷达和光学图像融合的多目标生命体征检测系统。该系统采用融合算法来提高检测速度和精度。通过将测量数据与参考信号进行比较,可以认为测量数据具有一定的准确性。心率(HR)检测的平均绝对误差为每分钟 4 次,而呼吸频率(RR)检测的误差为每分钟 0.75 次。心率检测的准确率为 91.61%,而呼吸频率检测的准确率为 99.01%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-target vital signs detection by fusing radar and optical images
Microwave radar has wide applications in the field of vital sign detection, but there are still some challenges in detecting multiple people in complex environments. For this problem, in this article, a multi-target vital signs detection system based on the fusion of radar and optical image is proposed. This system employs a fusion algorithm to enhance the speed and precision of detection. By comparing the measured data with the reference signal, it can be considered that the measured data has a certain accuracy. The average absolute error in heart rate (HR) detection was 4 beats per minute (BPM), while respiratory rate (RR) detection exhibited an error of 0.75 respirations per minute (RPM). The accuracy of heart rate detection stood at 91.61%, while respiratory rate detection accuracy attained 99.01%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信