{"title":"变压器矿物油箱表面在初期匝间短路故障下的热特性","authors":"Si Chen, Yingting Luo, Gehao Sheng, Junfei Jiang","doi":"10.1049/smt2.12200","DOIUrl":null,"url":null,"abstract":"<p>A slight turn-to-turn short-circuit fault in the incipient stage does not trigger fuse protection, and the regular transmission and transformation functions of the transformer within the power grid are not affected very much by the incipient turn-to-turn short-circuit fault. Therefore, the incipient turn-to-turn short-circuit faults are often undetected, resulting in massive accidents. Incipient turn-to-turn short-circuit faults lead to localized overheating in the transformer, which changes the transformer's oil-tank surface temperature (OTST). A thermal simulation model (TSM) is presented. Based on the TSM, OTST data with different load rates and fault parameters are collected. The steady-state and transient characteristics of OTST are analysed by extracting the OTST feature vector and the temperature difference of specific regions. The results show that the growth of the heat production value of faulty coils causes a rise in the OTST; higher faulty coils' locations lead to wider OTST differences; the temperature difference's area S can follow the incipient short-circuit fault in the first 20 min after it occurs, which is faster than the top oil temperature. This study gives insight into the thermal behaviour of OTST, assisting in fault detection and location at the incipient fault stage.</p>","PeriodicalId":54999,"journal":{"name":"Iet Science Measurement & Technology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/smt2.12200","citationCount":"0","resultStr":"{\"title\":\"Thermal behaviour of a transformer mineral oil-tank surface under incipient turn-to-turn short-circuit fault\",\"authors\":\"Si Chen, Yingting Luo, Gehao Sheng, Junfei Jiang\",\"doi\":\"10.1049/smt2.12200\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A slight turn-to-turn short-circuit fault in the incipient stage does not trigger fuse protection, and the regular transmission and transformation functions of the transformer within the power grid are not affected very much by the incipient turn-to-turn short-circuit fault. Therefore, the incipient turn-to-turn short-circuit faults are often undetected, resulting in massive accidents. Incipient turn-to-turn short-circuit faults lead to localized overheating in the transformer, which changes the transformer's oil-tank surface temperature (OTST). A thermal simulation model (TSM) is presented. Based on the TSM, OTST data with different load rates and fault parameters are collected. The steady-state and transient characteristics of OTST are analysed by extracting the OTST feature vector and the temperature difference of specific regions. The results show that the growth of the heat production value of faulty coils causes a rise in the OTST; higher faulty coils' locations lead to wider OTST differences; the temperature difference's area S can follow the incipient short-circuit fault in the first 20 min after it occurs, which is faster than the top oil temperature. This study gives insight into the thermal behaviour of OTST, assisting in fault detection and location at the incipient fault stage.</p>\",\"PeriodicalId\":54999,\"journal\":{\"name\":\"Iet Science Measurement & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/smt2.12200\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Science Measurement & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/smt2.12200\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Science Measurement & Technology","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/smt2.12200","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Thermal behaviour of a transformer mineral oil-tank surface under incipient turn-to-turn short-circuit fault
A slight turn-to-turn short-circuit fault in the incipient stage does not trigger fuse protection, and the regular transmission and transformation functions of the transformer within the power grid are not affected very much by the incipient turn-to-turn short-circuit fault. Therefore, the incipient turn-to-turn short-circuit faults are often undetected, resulting in massive accidents. Incipient turn-to-turn short-circuit faults lead to localized overheating in the transformer, which changes the transformer's oil-tank surface temperature (OTST). A thermal simulation model (TSM) is presented. Based on the TSM, OTST data with different load rates and fault parameters are collected. The steady-state and transient characteristics of OTST are analysed by extracting the OTST feature vector and the temperature difference of specific regions. The results show that the growth of the heat production value of faulty coils causes a rise in the OTST; higher faulty coils' locations lead to wider OTST differences; the temperature difference's area S can follow the incipient short-circuit fault in the first 20 min after it occurs, which is faster than the top oil temperature. This study gives insight into the thermal behaviour of OTST, assisting in fault detection and location at the incipient fault stage.
期刊介绍:
IET Science, Measurement & Technology publishes papers in science, engineering and technology underpinning electronic and electrical engineering, nanotechnology and medical instrumentation.The emphasis of the journal is on theory, simulation methodologies and measurement techniques.
The major themes of the journal are:
- electromagnetism including electromagnetic theory, computational electromagnetics and EMC
- properties and applications of dielectric, magnetic, magneto-optic, piezoelectric materials down to the nanometre scale
- measurement and instrumentation including sensors, actuators, medical instrumentation, fundamentals of measurement including measurement standards, uncertainty, dissemination and calibration
Applications are welcome for illustrative purposes but the novelty and originality should focus on the proposed new methods.