用于甲苯污染场地地下水修复的芬顿反应地下水循环井

Biao Yu, Zhihui Qu, Liuhui Jiang, Haowei Yuan, Yan Su, Qian Liu
{"title":"用于甲苯污染场地地下水修复的芬顿反应地下水循环井","authors":"Biao Yu, Zhihui Qu, Liuhui Jiang, Haowei Yuan, Yan Su, Qian Liu","doi":"10.2166/wpt.2024.155","DOIUrl":null,"url":null,"abstract":"\n \n In order to improve the remediation efficiency of the groundwater circulation well (GCW) on toluene-contaminated soil, we used a combination of GCW and Fenton reagent for remediation. Taking a toluene-contaminated site in Suzhou City, Jiangsu Province, China, as an example, Fenton reagent with a molar ratio of H2O2/contaminant = 10:1 and H2O2/Fe2+ = 2:1 was added to GCW at an aeration rate of 0.005 m3/s. After 216 h of remediation, the toluene concentrations at the site were reduced to the remediation target values. In this study, the Fenton reagent was rapidly delivered to the influence radius of GCW, which reduced the time required for remediation and provided a new model for the application of GCW.","PeriodicalId":104096,"journal":{"name":"Water Practice & Technology","volume":" 464","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fenton-reactive groundwater circulation well for groundwater remediation of a toluene-contaminated site\",\"authors\":\"Biao Yu, Zhihui Qu, Liuhui Jiang, Haowei Yuan, Yan Su, Qian Liu\",\"doi\":\"10.2166/wpt.2024.155\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n \\n In order to improve the remediation efficiency of the groundwater circulation well (GCW) on toluene-contaminated soil, we used a combination of GCW and Fenton reagent for remediation. Taking a toluene-contaminated site in Suzhou City, Jiangsu Province, China, as an example, Fenton reagent with a molar ratio of H2O2/contaminant = 10:1 and H2O2/Fe2+ = 2:1 was added to GCW at an aeration rate of 0.005 m3/s. After 216 h of remediation, the toluene concentrations at the site were reduced to the remediation target values. In this study, the Fenton reagent was rapidly delivered to the influence radius of GCW, which reduced the time required for remediation and provided a new model for the application of GCW.\",\"PeriodicalId\":104096,\"journal\":{\"name\":\"Water Practice & Technology\",\"volume\":\" 464\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Practice & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/wpt.2024.155\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Practice & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/wpt.2024.155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了提高地下水循环井对甲苯污染土壤的修复效率,我们采用了地下水循环井和芬顿试剂相结合的修复方法。以江苏省苏州市的一处甲苯污染场地为例,将摩尔比为 H2O2/污染物=10:1、H2O2/Fe2+=2:1 的芬顿试剂添加到 GCW 中,曝气速度为 0.005 m3/s。经过 216 小时的修复,现场的甲苯浓度降至修复目标值。在这项研究中,芬顿试剂被迅速输送到 GCW 的影响半径,从而缩短了修复所需的时间,并为 GCW 的应用提供了一种新的模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fenton-reactive groundwater circulation well for groundwater remediation of a toluene-contaminated site
In order to improve the remediation efficiency of the groundwater circulation well (GCW) on toluene-contaminated soil, we used a combination of GCW and Fenton reagent for remediation. Taking a toluene-contaminated site in Suzhou City, Jiangsu Province, China, as an example, Fenton reagent with a molar ratio of H2O2/contaminant = 10:1 and H2O2/Fe2+ = 2:1 was added to GCW at an aeration rate of 0.005 m3/s. After 216 h of remediation, the toluene concentrations at the site were reduced to the remediation target values. In this study, the Fenton reagent was rapidly delivered to the influence radius of GCW, which reduced the time required for remediation and provided a new model for the application of GCW.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信