利用光谱分析(中心点法)评估尼日利亚索科托盆地西南部的地热参数

U. Z. Magawata, N. Olasunkanmi, T. A. Issa
{"title":"利用光谱分析(中心点法)评估尼日利亚索科托盆地西南部的地热参数","authors":"U. Z. Magawata, N. Olasunkanmi, T. A. Issa","doi":"10.61298/rans.2024.2.1.47","DOIUrl":null,"url":null,"abstract":"This study utilized spectral analysis (centroid method) to assess geothermal parameters in the southwestern part of the Sokoto Basin, Nigeria. The high-resolution airborne data comprised forty-nine (49) overlapping blocks, and each block was divided into 55x55 km to evaluate essential parameters such as depth to the top boundary (Zt ), centroiddepth (Zo), and magnetic source bottom (Zb = 2Zo-Zt ). The analysis revealed variable Curie points depths (CPD), ranging from 3.89 km to 26.56 km. The lowest CPD is primarily associated with basement rocks within anomalies A, B, C, D, E, F, G, H, and I, with an average CPD of 9.16 km. Furthermore, the thermal gradients ranged from 21.84 ◦C/km to 149.10 ◦C/km, with an average thermal gradient of 73.30 ◦C/km. The heat flow exhibited variations between 54.81 mW/m² and 374.24 mW/m², with average heat flow of 180.4 mW/m², indicating significant geothermal potential zones. The high thermal gradients and heat flow regions were identified, around anomalies A, B, and C. Additionally, temperature gradients identified at shallow depths ranged from 110 ◦C/km to 150 ◦C/km. The results reveal the presence of high-temperature points and anomalous geothermal potentials, particularly within anomalies A, B, and C, thus requiring further for sustainable geothermal energy generation in the study area.","PeriodicalId":478520,"journal":{"name":"Recent Advances in Natural Sciences","volume":"80 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Geothermal parameter assessment in the Southwestern Sokoto Basin, Nigeria, using spectral analysis (centroid method)\",\"authors\":\"U. Z. Magawata, N. Olasunkanmi, T. A. Issa\",\"doi\":\"10.61298/rans.2024.2.1.47\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study utilized spectral analysis (centroid method) to assess geothermal parameters in the southwestern part of the Sokoto Basin, Nigeria. The high-resolution airborne data comprised forty-nine (49) overlapping blocks, and each block was divided into 55x55 km to evaluate essential parameters such as depth to the top boundary (Zt ), centroiddepth (Zo), and magnetic source bottom (Zb = 2Zo-Zt ). The analysis revealed variable Curie points depths (CPD), ranging from 3.89 km to 26.56 km. The lowest CPD is primarily associated with basement rocks within anomalies A, B, C, D, E, F, G, H, and I, with an average CPD of 9.16 km. Furthermore, the thermal gradients ranged from 21.84 ◦C/km to 149.10 ◦C/km, with an average thermal gradient of 73.30 ◦C/km. The heat flow exhibited variations between 54.81 mW/m² and 374.24 mW/m², with average heat flow of 180.4 mW/m², indicating significant geothermal potential zones. The high thermal gradients and heat flow regions were identified, around anomalies A, B, and C. Additionally, temperature gradients identified at shallow depths ranged from 110 ◦C/km to 150 ◦C/km. The results reveal the presence of high-temperature points and anomalous geothermal potentials, particularly within anomalies A, B, and C, thus requiring further for sustainable geothermal energy generation in the study area.\",\"PeriodicalId\":478520,\"journal\":{\"name\":\"Recent Advances in Natural Sciences\",\"volume\":\"80 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Recent Advances in Natural Sciences\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.61298/rans.2024.2.1.47\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Advances in Natural Sciences","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.61298/rans.2024.2.1.47","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究利用光谱分析(中心点法)评估尼日利亚索科托盆地西南部的地热参数。高分辨率机载数据由四十九(49)个重叠区块组成,每个区块被划分为 55x55 公里,用于评估顶部边界深度(Zt)、中心深度(Zo)和磁源底部(Zb = 2Zo-Zt)等基本参数。分析结果显示,居里点深度(CPD)从 3.89 千米到 26.56 千米不等。最低居里点深度主要与异常点 A、B、C、D、E、F、G、H 和 I 内的基底岩石有关,平均居里点深度为 9.16 千米。此外,热梯度介于 21.84 ◦C/km 至 149.10 ◦C/km 之间,平均热梯度为 73.30 ◦C/km。热流量在 54.81 mW/m² 至 374.24 mW/m² 之间变化,平均热流量为 180.4 mW/m²,表明地热潜力区很大。此外,在浅层发现的温度梯度在 110 ◦C/km 至 150 ◦C/km 之间。研究结果显示存在高温点和异常地热潜力,特别是在异常区 A、B 和 C 内,因此需要进一步在研究区域进行可持续地热能源生产。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Geothermal parameter assessment in the Southwestern Sokoto Basin, Nigeria, using spectral analysis (centroid method)
This study utilized spectral analysis (centroid method) to assess geothermal parameters in the southwestern part of the Sokoto Basin, Nigeria. The high-resolution airborne data comprised forty-nine (49) overlapping blocks, and each block was divided into 55x55 km to evaluate essential parameters such as depth to the top boundary (Zt ), centroiddepth (Zo), and magnetic source bottom (Zb = 2Zo-Zt ). The analysis revealed variable Curie points depths (CPD), ranging from 3.89 km to 26.56 km. The lowest CPD is primarily associated with basement rocks within anomalies A, B, C, D, E, F, G, H, and I, with an average CPD of 9.16 km. Furthermore, the thermal gradients ranged from 21.84 ◦C/km to 149.10 ◦C/km, with an average thermal gradient of 73.30 ◦C/km. The heat flow exhibited variations between 54.81 mW/m² and 374.24 mW/m², with average heat flow of 180.4 mW/m², indicating significant geothermal potential zones. The high thermal gradients and heat flow regions were identified, around anomalies A, B, and C. Additionally, temperature gradients identified at shallow depths ranged from 110 ◦C/km to 150 ◦C/km. The results reveal the presence of high-temperature points and anomalous geothermal potentials, particularly within anomalies A, B, and C, thus requiring further for sustainable geothermal energy generation in the study area.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信