作为睑板腺功能障碍治疗方法的定向热脉冲疗法:跨越 15 年的回顾。

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY
Ophthalmology and Therapy Pub Date : 2024-08-01 Epub Date: 2024-06-15 DOI:10.1007/s40123-024-00976-1
Caroline A Blackie, David Murakami, Eric Donnenfeld, Heather S Oliff
{"title":"作为睑板腺功能障碍治疗方法的定向热脉冲疗法:跨越 15 年的回顾。","authors":"Caroline A Blackie, David Murakami, Eric Donnenfeld, Heather S Oliff","doi":"10.1007/s40123-024-00976-1","DOIUrl":null,"url":null,"abstract":"<p><p>The LipiFlow Thermal Pulsation System received its first marketing clearance for the treatment of meibomian gland dysfunction (MGD) 13 years ago. Since then, the evidence evaluating the effectiveness and safety of LipiFlow as a treatment for MGD has grown significantly. The objective of this comprehensive review was to summarize all clinical reports evaluating the effectiveness and safety of LipiFlow over the past 15 years. The literature was systematically reviewed, and 55 unique articles had subjective (patient-reported outcomes) and objective (meibomian gland function, tear production, and ocular staining) outcomes for extraction. Data were collected from 2101 patients and 3521 eyes treated with LipiFlow. Of these, effectiveness was evaluated in 2041 patients and 3401 eyes, and safety was evaluated in 1448 patients and 2443 eyes. Taken together, the studies demonstrate that a single 12-min treatment with LipiFlow safely improves signs and symptoms of MGD and associated evaporative dry eye disease (DED), and the benefits persist up to 3 years in some cases. The findings are corroborated by multiple meta-analyses and consensus guidelines. While some studies showed that daily eyelid hygiene, warm compress, and/or massage had a similar benefit to a single LipiFlow, these treatments were limited by inconvenience, discomfort, and non-compliance. The majority of studies evaluating safety reported no discomfort or pain associated with LipiFlow treatment, which supports the patient acceptability of LipiFlow therapy. All adverse events (AEs) related to LipiFlow were transient, non-vision-threatening, and did not require treatment. No studies reported serious AEs. The data obtained from 55 studies conducted globally overwhelmingly show that LipiFlow is effective and safe for the treatment of MGD and associated evaporative DED. The conclusions are supported by the diversity of the patient populations (geography, race, disease severity, and diagnosis), the large population treated with LipiFlow, the meta-analyses, and that this review analyzed all published clinical studies to date.</p>","PeriodicalId":19623,"journal":{"name":"Ophthalmology and Therapy","volume":" ","pages":"2083-2123"},"PeriodicalIF":2.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11246355/pdf/","citationCount":"0","resultStr":"{\"title\":\"Vectored Thermal Pulsation as a Treatment for Meibomian Gland Dysfunction: A Review Spanning 15 Years.\",\"authors\":\"Caroline A Blackie, David Murakami, Eric Donnenfeld, Heather S Oliff\",\"doi\":\"10.1007/s40123-024-00976-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The LipiFlow Thermal Pulsation System received its first marketing clearance for the treatment of meibomian gland dysfunction (MGD) 13 years ago. Since then, the evidence evaluating the effectiveness and safety of LipiFlow as a treatment for MGD has grown significantly. The objective of this comprehensive review was to summarize all clinical reports evaluating the effectiveness and safety of LipiFlow over the past 15 years. The literature was systematically reviewed, and 55 unique articles had subjective (patient-reported outcomes) and objective (meibomian gland function, tear production, and ocular staining) outcomes for extraction. Data were collected from 2101 patients and 3521 eyes treated with LipiFlow. Of these, effectiveness was evaluated in 2041 patients and 3401 eyes, and safety was evaluated in 1448 patients and 2443 eyes. Taken together, the studies demonstrate that a single 12-min treatment with LipiFlow safely improves signs and symptoms of MGD and associated evaporative dry eye disease (DED), and the benefits persist up to 3 years in some cases. The findings are corroborated by multiple meta-analyses and consensus guidelines. While some studies showed that daily eyelid hygiene, warm compress, and/or massage had a similar benefit to a single LipiFlow, these treatments were limited by inconvenience, discomfort, and non-compliance. The majority of studies evaluating safety reported no discomfort or pain associated with LipiFlow treatment, which supports the patient acceptability of LipiFlow therapy. All adverse events (AEs) related to LipiFlow were transient, non-vision-threatening, and did not require treatment. No studies reported serious AEs. The data obtained from 55 studies conducted globally overwhelmingly show that LipiFlow is effective and safe for the treatment of MGD and associated evaporative DED. The conclusions are supported by the diversity of the patient populations (geography, race, disease severity, and diagnosis), the large population treated with LipiFlow, the meta-analyses, and that this review analyzed all published clinical studies to date.</p>\",\"PeriodicalId\":19623,\"journal\":{\"name\":\"Ophthalmology and Therapy\",\"volume\":\" \",\"pages\":\"2083-2123\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11246355/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmology and Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s40123-024-00976-1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology and Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s40123-024-00976-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

13 年前,LipiFlow 热脉冲系统首次获得了治疗睑板腺功能障碍 (MGD) 的上市许可。从那时起,评估 LipiFlow 治疗睑板腺功能障碍的有效性和安全性的证据显著增加。本次全面综述的目的是总结过去 15 年中评估 LipiFlow 有效性和安全性的所有临床报告。我们对文献进行了系统性的回顾,其中 55 篇文章对主观(患者报告结果)和客观(睑板腺功能、泪液分泌和眼部染色)结果进行了提取。收集了 2101 名患者和 3521 只接受过 LipiFlow 治疗的眼睛的数据。其中,对 2041 名患者和 3401 只眼睛进行了有效性评估,对 1448 名患者和 2443 只眼睛进行了安全性评估。总之,这些研究表明,使用 LipiFlow 进行 12 分钟的单次治疗可安全地改善并发症和相关的蒸发性干眼症 (DED) 的症状和体征,在某些病例中,疗效可持续 3 年之久。这些研究结果得到了多项荟萃分析和共识指南的证实。一些研究表明,日常眼睑卫生、热敷和/或按摩与单次使用 LipiFlow 的疗效相似,但这些疗法受到不便、不适和不依从性的限制。大多数评估安全性的研究报告称,LipiFlow疗法不会带来不适或疼痛,这证明了患者对LipiFlow疗法的可接受性。所有与 LipiFlow 相关的不良事件(AEs)都是短暂的,不会危及视力,也不需要治疗。没有研究报告严重的不良反应。从全球进行的 55 项研究中获得的数据压倒性地表明,LipiFlow 对治疗镁光泪管发育不良和相关的蒸发性 DED 有效且安全。患者群体的多样性(地域、种族、疾病严重程度和诊断)、大量接受 LipiFlow 治疗的人群、荟萃分析以及本综述分析了迄今为止已发表的所有临床研究都支持上述结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Vectored Thermal Pulsation as a Treatment for Meibomian Gland Dysfunction: A Review Spanning 15 Years.

Vectored Thermal Pulsation as a Treatment for Meibomian Gland Dysfunction: A Review Spanning 15 Years.

The LipiFlow Thermal Pulsation System received its first marketing clearance for the treatment of meibomian gland dysfunction (MGD) 13 years ago. Since then, the evidence evaluating the effectiveness and safety of LipiFlow as a treatment for MGD has grown significantly. The objective of this comprehensive review was to summarize all clinical reports evaluating the effectiveness and safety of LipiFlow over the past 15 years. The literature was systematically reviewed, and 55 unique articles had subjective (patient-reported outcomes) and objective (meibomian gland function, tear production, and ocular staining) outcomes for extraction. Data were collected from 2101 patients and 3521 eyes treated with LipiFlow. Of these, effectiveness was evaluated in 2041 patients and 3401 eyes, and safety was evaluated in 1448 patients and 2443 eyes. Taken together, the studies demonstrate that a single 12-min treatment with LipiFlow safely improves signs and symptoms of MGD and associated evaporative dry eye disease (DED), and the benefits persist up to 3 years in some cases. The findings are corroborated by multiple meta-analyses and consensus guidelines. While some studies showed that daily eyelid hygiene, warm compress, and/or massage had a similar benefit to a single LipiFlow, these treatments were limited by inconvenience, discomfort, and non-compliance. The majority of studies evaluating safety reported no discomfort or pain associated with LipiFlow treatment, which supports the patient acceptability of LipiFlow therapy. All adverse events (AEs) related to LipiFlow were transient, non-vision-threatening, and did not require treatment. No studies reported serious AEs. The data obtained from 55 studies conducted globally overwhelmingly show that LipiFlow is effective and safe for the treatment of MGD and associated evaporative DED. The conclusions are supported by the diversity of the patient populations (geography, race, disease severity, and diagnosis), the large population treated with LipiFlow, the meta-analyses, and that this review analyzed all published clinical studies to date.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ophthalmology and Therapy
Ophthalmology and Therapy OPHTHALMOLOGY-
CiteScore
4.20
自引率
3.00%
发文量
157
审稿时长
6 weeks
期刊介绍: Aims and Scope Ophthalmology and Therapy is an international, open access, peer-reviewed (single-blind), and rapid publication journal. The scope of the journal is broad and will consider all scientifically sound research from preclinical, clinical (all phases), observational, real-world, and health outcomes research around the use of ophthalmological therapies, devices, and surgical techniques. The journal is of interest to a broad audience of pharmaceutical and healthcare professionals and publishes original research, reviews, case reports/series, trial protocols and short communications such as commentaries and editorials. Ophthalmology and Therapy will consider all scientifically sound research be it positive, confirmatory or negative data. Submissions are welcomed whether they relate to an international and/or a country-specific audience, something that is crucially important when researchers are trying to target more specific patient populations. This inclusive approach allows the journal to assist in the dissemination of quality research, which may be considered of insufficient interest by other journals. Rapid Publication The journal’s publication timelines aim for a rapid peer review of 2 weeks. If an article is accepted it will be published 3–4 weeks from acceptance. The rapid timelines are achieved through the combination of a dedicated in-house editorial team, who manage article workflow, and an extensive Editorial and Advisory Board who assist with peer review. This allows the journal to support the rapid dissemination of research, whilst still providing robust peer review. Combined with the journal’s open access model this allows for the rapid, efficient communication of the latest research and reviews, fostering the advancement of ophthalmic therapies. Open Access All articles published by Ophthalmology and Therapy are open access. Personal Service The journal’s dedicated in-house editorial team offer a personal “concierge service” meaning authors will always have an editorial contact able to update them on the status of their manuscript. The editorial team check all manuscripts to ensure that articles conform to the most recent COPE, GPP and ICMJE publishing guidelines. This supports the publication of ethically sound and transparent research. Digital Features and Plain Language Summaries Ophthalmology and Therapy offers a range of additional features designed to increase the visibility, readership and educational value of the journal’s content. Each article is accompanied by key summary points, giving a time-efficient overview of the content to a wide readership. Articles may be accompanied by plain language summaries to assist readers who have some knowledge of, but not in-depth expertise in, the area to understand the scientific content and overall implications of the article. The journal also provides the option to include various types of digital features including animated abstracts, video abstracts, slide decks, audio slides, instructional videos, infographics, podcasts and animations. All additional features are peer reviewed to the same high standard as the article itself. If you consider that your paper would benefit from the inclusion of a digital feature, please let us know. Our editorial team are able to create high-quality slide decks and infographics in-house, and video abstracts through our partner Research Square, and would be happy to assist in any way we can. For further information about digital features, please contact the journal editor (see ‘Contact the Journal’ for email address), and see the ‘Guidelines for digital features and plain language summaries’ document under ‘Submission guidelines’. For examples of digital features please visit our showcase page https://springerhealthcare.com/expertise/publishing-digital-features/ Publication Fees Upon acceptance of an article, authors will be required to pay the mandatory Rapid Service Fee of €5250/$6000/£4300. The journal will consider fee discounts and waivers for developing countries and this is decided on a case by case basis. Peer Review Process Upon submission, manuscripts are assessed by the editorial team to ensure they fit within the aims and scope of the journal and are also checked for plagiarism. All suitable submissions are then subject to a comprehensive single-blind peer review. Reviewers are selected based on their relevant expertise and publication history in the subject area. The journal has an extensive pool of editorial and advisory board members who have been selected to assist with peer review based on the afore-mentioned criteria. At least two extensive reviews are required to make the editorial decision, with the exception of some article types such as Commentaries, Editorials, and Letters which are generally reviewed by one member of the Editorial Board. Where reviewer recommendations are conflicted, the editorial board will be contacted for further advice and a presiding decision. Manuscripts are then either accepted, rejected or authors are required to make major or minor revisions (both reviewer comments and editorial comments may need to be addressed). Once a revised manuscript is re-submitted, it is assessed along with the responses to reviewer comments and if it has been adequately revised it will be accepted for publication. Accepted manuscripts are then copyedited and typeset by the production team before online publication. Appeals against decisions following peer review are considered on a case-by-case basis and should be sent to the journal editor. Preprints We encourage posting of preprints of primary research manuscripts on preprint servers, authors’ or institutional websites, and open communications between researchers whether on community preprint servers or preprint commenting platforms. Posting of preprints is not considered prior publication and will not jeopardize consideration in our journals. Authors should disclose details of preprint posting during the submission process or at any other point during consideration in one of our journals. Once the manuscript is published, it is the author’s responsibility to ensure that the preprint record is updated with a publication reference, including the DOI and a URL link to the published version of the article on the journal website. Please follow the link for further information on preprint sharing: https://www.springer.com/gp/authors-editors/journal-author/journal-author-helpdesk/submission/1302#c16721550 Copyright Ophthalmology and Therapy''s content is published open access under the Creative Commons Attribution-Noncommercial License, which allows users to read, copy, distribute, and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited. The author assigns the exclusive right to any commercial use of the article to Springer. For more information about the Creative Commons Attribution-Noncommercial License, click here: http://creativecommons.org/licenses/by-nc/4.0. Contact For more information about the journal, including pre-submission enquiries, please contact christopher.vautrinot@springer.com.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信