Greta Smidt, Shang Gao, Divya Iyer, Samanvaya Srivastava, Kumar C Shah
{"title":"现代牙科材料中单体浸出的体外分析:CAD 铣削、印刷、传统热加工和自动聚合义齿基底树脂。","authors":"Greta Smidt, Shang Gao, Divya Iyer, Samanvaya Srivastava, Kumar C Shah","doi":"10.1111/jopr.13874","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Denture fabrication has shifted from traditional heat-processed and auto-polymerizing materials to computer-aided design and computer-aided manufacturing (CAD-CAM) milled and printed materials. The monomer in traditional materials can induce an allergic reaction in some patients. With the rise in the edentulous population and increasing demand for the fabrication of dentures, these newer materials should be studied for monomer leaching. The purpose of this study was to evaluate the ratio of residual monomer in materials being used for denture bases: CAD-milled polymethylmethacrylate (PMMA), printed denture base resin, heat-processed PMMA, and auto-polymerizing PMMA comparatively.</p><p><strong>Materials and methods: </strong>Milled, printed, heat-activated, and auto-polymerizing denture base specimens (n = 3 for each group, each test run three times) were fabricated according to manufacturer recommendations. Specimens were first immersed in deuterated chloroform (CDCl<sub>3</sub>), a deuterated organic solvent, to evaluate monomer leaching and to observe physical properties of the materials. NMR spectroscopy was used to evaluate the dissolution of materials and residual monomer to crosslinked polymer ratios at 1, 4, and 9 days. A second group of specimens was then immersed in deuterium oxide (D<sub>2</sub>O) to evaluate if the residual monomers would leach out of the system. The solution was then analyzed using nuclear magnetic resonance (NMR) spectroscopy for 1 month. The deuterated forms of chloroform (CDCl<sub>3</sub>) and water (D<sub>2</sub>O) were used to enable sample characterization by NMR.</p><p><strong>Results: </strong>While the heat-processed, auto-polymerizing, and milled specimens possessed residual monomers, no significant monomer leaching was noted in the printed specimen, while immersed in CDCl<sub>3</sub>. Similarly, the printed specimen was most resistant to dissolution, as compared to the rest; dissolution of the specimen is indicative of little to no cross-linking. No detectable dissolution of monomer was seen when all specimens were immersed in D<sub>2</sub>O for up to 1 month.</p><p><strong>Conclusions: </strong>Residual monomers were not found in the printed denture material in this study in either CDCl<sub>3</sub> or D<sub>2</sub>O, whereas CAD-milled and traditionally processed denture bases still have residual monomers within their respective systems when immersed in organic solvent. None of the specimens tested leached monomers into D<sub>2</sub>O.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro analysis of monomer leaching in modern dental materials: CAD milled, printed, traditional heat-processed, and auto-polymerizing denture base resins.\",\"authors\":\"Greta Smidt, Shang Gao, Divya Iyer, Samanvaya Srivastava, Kumar C Shah\",\"doi\":\"10.1111/jopr.13874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Denture fabrication has shifted from traditional heat-processed and auto-polymerizing materials to computer-aided design and computer-aided manufacturing (CAD-CAM) milled and printed materials. The monomer in traditional materials can induce an allergic reaction in some patients. With the rise in the edentulous population and increasing demand for the fabrication of dentures, these newer materials should be studied for monomer leaching. The purpose of this study was to evaluate the ratio of residual monomer in materials being used for denture bases: CAD-milled polymethylmethacrylate (PMMA), printed denture base resin, heat-processed PMMA, and auto-polymerizing PMMA comparatively.</p><p><strong>Materials and methods: </strong>Milled, printed, heat-activated, and auto-polymerizing denture base specimens (n = 3 for each group, each test run three times) were fabricated according to manufacturer recommendations. Specimens were first immersed in deuterated chloroform (CDCl<sub>3</sub>), a deuterated organic solvent, to evaluate monomer leaching and to observe physical properties of the materials. NMR spectroscopy was used to evaluate the dissolution of materials and residual monomer to crosslinked polymer ratios at 1, 4, and 9 days. A second group of specimens was then immersed in deuterium oxide (D<sub>2</sub>O) to evaluate if the residual monomers would leach out of the system. The solution was then analyzed using nuclear magnetic resonance (NMR) spectroscopy for 1 month. The deuterated forms of chloroform (CDCl<sub>3</sub>) and water (D<sub>2</sub>O) were used to enable sample characterization by NMR.</p><p><strong>Results: </strong>While the heat-processed, auto-polymerizing, and milled specimens possessed residual monomers, no significant monomer leaching was noted in the printed specimen, while immersed in CDCl<sub>3</sub>. Similarly, the printed specimen was most resistant to dissolution, as compared to the rest; dissolution of the specimen is indicative of little to no cross-linking. No detectable dissolution of monomer was seen when all specimens were immersed in D<sub>2</sub>O for up to 1 month.</p><p><strong>Conclusions: </strong>Residual monomers were not found in the printed denture material in this study in either CDCl<sub>3</sub> or D<sub>2</sub>O, whereas CAD-milled and traditionally processed denture bases still have residual monomers within their respective systems when immersed in organic solvent. None of the specimens tested leached monomers into D<sub>2</sub>O.</p>\",\"PeriodicalId\":49152,\"journal\":{\"name\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jopr.13874\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13874","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
In vitro analysis of monomer leaching in modern dental materials: CAD milled, printed, traditional heat-processed, and auto-polymerizing denture base resins.
Purpose: Denture fabrication has shifted from traditional heat-processed and auto-polymerizing materials to computer-aided design and computer-aided manufacturing (CAD-CAM) milled and printed materials. The monomer in traditional materials can induce an allergic reaction in some patients. With the rise in the edentulous population and increasing demand for the fabrication of dentures, these newer materials should be studied for monomer leaching. The purpose of this study was to evaluate the ratio of residual monomer in materials being used for denture bases: CAD-milled polymethylmethacrylate (PMMA), printed denture base resin, heat-processed PMMA, and auto-polymerizing PMMA comparatively.
Materials and methods: Milled, printed, heat-activated, and auto-polymerizing denture base specimens (n = 3 for each group, each test run three times) were fabricated according to manufacturer recommendations. Specimens were first immersed in deuterated chloroform (CDCl3), a deuterated organic solvent, to evaluate monomer leaching and to observe physical properties of the materials. NMR spectroscopy was used to evaluate the dissolution of materials and residual monomer to crosslinked polymer ratios at 1, 4, and 9 days. A second group of specimens was then immersed in deuterium oxide (D2O) to evaluate if the residual monomers would leach out of the system. The solution was then analyzed using nuclear magnetic resonance (NMR) spectroscopy for 1 month. The deuterated forms of chloroform (CDCl3) and water (D2O) were used to enable sample characterization by NMR.
Results: While the heat-processed, auto-polymerizing, and milled specimens possessed residual monomers, no significant monomer leaching was noted in the printed specimen, while immersed in CDCl3. Similarly, the printed specimen was most resistant to dissolution, as compared to the rest; dissolution of the specimen is indicative of little to no cross-linking. No detectable dissolution of monomer was seen when all specimens were immersed in D2O for up to 1 month.
Conclusions: Residual monomers were not found in the printed denture material in this study in either CDCl3 or D2O, whereas CAD-milled and traditionally processed denture bases still have residual monomers within their respective systems when immersed in organic solvent. None of the specimens tested leached monomers into D2O.
期刊介绍:
The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.