Nicolas Cance, Aymeric Rouchaud, Aygulph Chousta, Antoine Josse, Michael James Dan, Franck Chotel
{"title":"动态磁共振成像协议:评估儿童盘状外侧半月板不稳定性的有效实用工具。","authors":"Nicolas Cance, Aymeric Rouchaud, Aygulph Chousta, Antoine Josse, Michael James Dan, Franck Chotel","doi":"10.1097/BPO.0000000000002747","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>One of the most common symptoms in cases of discoid lateral meniscus (DLM) in children is a \"snapping\" knee. The clock in extension, followed by a pop in flexion, perceived by the clinician, reflects the meniscal displacement caused by the peripheral meniscocapsular detachment. Standard magnetic resonance imaging (MRI) results in a 40% false-negative rate for detecting this instability. The hypothesis was that a dynamic MRI protocol could reduce the false negative rate and improve the efficiency of the MRI in detecting the direction of instability.</p><p><strong>Methods: </strong>Eight DLM knees (8 patients) with snapping knees (grade 2 of Lyon's classification) were included in this monocentric prospective preliminary study in a referral center of pediatric orthopaedic surgery. Every patient underwent a dynamic MRI protocol with both T2-Fat-Sat sagittal and coronal slices, performed \"after the clock\" and again \"after the pop\" in a knee with standard 20 degrees of flexion during acquisition. All the MRI data were correlated with an arthroscopic description of the peripheral tear of the DLM according to Ahn's classification to assess for diagnostic accuracy.</p><p><strong>Results: </strong>The standard MRI protocol resulted in a false-negative rate of 50% for detecting the direction of instability. The dynamic MRI protocol allowed the identification of, and classification of the meniscal instability, meniscal shift, and meniscocapsular tear in 8 of 8 patients (0% false-negative rate), perfectly correlated with arthroscopic findings.</p><p><strong>Conclusion: </strong>This preliminary series, although short, allowed us to understand all the types of movements and lesions associated with the child's discoid meniscus. The detailed case analysis showed a strong benefit of such a protocol for planning the surgical suture procedure. The functionality and reliability of the dynamic MRI protocol is a good and method relatively simple method which does not require specific equipment, minimizing any additional cost compared with standard MRI.</p><p><strong>Level of evidence: </strong>Level IV.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic Magnetic Resonance Imaging Protocol: An Effective and Useful Tool to Assess Discoid Lateral Meniscus Instability in Children.\",\"authors\":\"Nicolas Cance, Aymeric Rouchaud, Aygulph Chousta, Antoine Josse, Michael James Dan, Franck Chotel\",\"doi\":\"10.1097/BPO.0000000000002747\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>One of the most common symptoms in cases of discoid lateral meniscus (DLM) in children is a \\\"snapping\\\" knee. The clock in extension, followed by a pop in flexion, perceived by the clinician, reflects the meniscal displacement caused by the peripheral meniscocapsular detachment. Standard magnetic resonance imaging (MRI) results in a 40% false-negative rate for detecting this instability. The hypothesis was that a dynamic MRI protocol could reduce the false negative rate and improve the efficiency of the MRI in detecting the direction of instability.</p><p><strong>Methods: </strong>Eight DLM knees (8 patients) with snapping knees (grade 2 of Lyon's classification) were included in this monocentric prospective preliminary study in a referral center of pediatric orthopaedic surgery. Every patient underwent a dynamic MRI protocol with both T2-Fat-Sat sagittal and coronal slices, performed \\\"after the clock\\\" and again \\\"after the pop\\\" in a knee with standard 20 degrees of flexion during acquisition. All the MRI data were correlated with an arthroscopic description of the peripheral tear of the DLM according to Ahn's classification to assess for diagnostic accuracy.</p><p><strong>Results: </strong>The standard MRI protocol resulted in a false-negative rate of 50% for detecting the direction of instability. The dynamic MRI protocol allowed the identification of, and classification of the meniscal instability, meniscal shift, and meniscocapsular tear in 8 of 8 patients (0% false-negative rate), perfectly correlated with arthroscopic findings.</p><p><strong>Conclusion: </strong>This preliminary series, although short, allowed us to understand all the types of movements and lesions associated with the child's discoid meniscus. The detailed case analysis showed a strong benefit of such a protocol for planning the surgical suture procedure. The functionality and reliability of the dynamic MRI protocol is a good and method relatively simple method which does not require specific equipment, minimizing any additional cost compared with standard MRI.</p><p><strong>Level of evidence: </strong>Level IV.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/BPO.0000000000002747\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPO.0000000000002747","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Dynamic Magnetic Resonance Imaging Protocol: An Effective and Useful Tool to Assess Discoid Lateral Meniscus Instability in Children.
Objectives: One of the most common symptoms in cases of discoid lateral meniscus (DLM) in children is a "snapping" knee. The clock in extension, followed by a pop in flexion, perceived by the clinician, reflects the meniscal displacement caused by the peripheral meniscocapsular detachment. Standard magnetic resonance imaging (MRI) results in a 40% false-negative rate for detecting this instability. The hypothesis was that a dynamic MRI protocol could reduce the false negative rate and improve the efficiency of the MRI in detecting the direction of instability.
Methods: Eight DLM knees (8 patients) with snapping knees (grade 2 of Lyon's classification) were included in this monocentric prospective preliminary study in a referral center of pediatric orthopaedic surgery. Every patient underwent a dynamic MRI protocol with both T2-Fat-Sat sagittal and coronal slices, performed "after the clock" and again "after the pop" in a knee with standard 20 degrees of flexion during acquisition. All the MRI data were correlated with an arthroscopic description of the peripheral tear of the DLM according to Ahn's classification to assess for diagnostic accuracy.
Results: The standard MRI protocol resulted in a false-negative rate of 50% for detecting the direction of instability. The dynamic MRI protocol allowed the identification of, and classification of the meniscal instability, meniscal shift, and meniscocapsular tear in 8 of 8 patients (0% false-negative rate), perfectly correlated with arthroscopic findings.
Conclusion: This preliminary series, although short, allowed us to understand all the types of movements and lesions associated with the child's discoid meniscus. The detailed case analysis showed a strong benefit of such a protocol for planning the surgical suture procedure. The functionality and reliability of the dynamic MRI protocol is a good and method relatively simple method which does not require specific equipment, minimizing any additional cost compared with standard MRI.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.