Louay Abd Al-Azez Mahdi, Hasanain Adnan Abdul Wahhab, Miqdam Tariq Chaichan
{"title":"管线式热交换器中从分层到分层-波浪式冷凝的流动模式变化","authors":"Louay Abd Al-Azez Mahdi, Hasanain Adnan Abdul Wahhab, Miqdam Tariq Chaichan","doi":"10.37934/arfmts.117.2.105115","DOIUrl":null,"url":null,"abstract":"Flow patterns inside wire-on-tube condensers with different refrigerant mass flow rates were studied in a theoretical study. In this study, tubes with diameters of 3.25 mm (3/16\"), 4.83 mm (1/4\") and 6.29 mm (5/16\") were used. R-134a and R-600a cooling fluids were used at condensing temperatures of 54.4°C, 45°C, and 35°C. The results of this study were obtained using Equal Equation Solver (EES) software. The proposed model was able to predict the type of refrigerant flow pattern based on the limitations reported in previous studies. It was possible to distinguish four kinds of flow patterns: laminar, wavy laminar, plugged, and spiral. The first variation in flow pattern from laminar to wavy laminar flow found between 0.8 and 0.39, and a second variation in flow pattern found from wavy laminar flow to plug or slug flow between 0.15 and 0.05. For the refrigerant conditions, the condensation temperature did not affect the flow pattern. When using R-134a, the inner tube diameter had no effect on the flow pattern. Change occurs with R-600a as inner diameter was increased.","PeriodicalId":37460,"journal":{"name":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","volume":"135 39","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Change of Flow Pattern from Stratified to Stratified-Wavy for Condensation in Wire on Tube Heat Exchangers\",\"authors\":\"Louay Abd Al-Azez Mahdi, Hasanain Adnan Abdul Wahhab, Miqdam Tariq Chaichan\",\"doi\":\"10.37934/arfmts.117.2.105115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Flow patterns inside wire-on-tube condensers with different refrigerant mass flow rates were studied in a theoretical study. In this study, tubes with diameters of 3.25 mm (3/16\\\"), 4.83 mm (1/4\\\") and 6.29 mm (5/16\\\") were used. R-134a and R-600a cooling fluids were used at condensing temperatures of 54.4°C, 45°C, and 35°C. The results of this study were obtained using Equal Equation Solver (EES) software. The proposed model was able to predict the type of refrigerant flow pattern based on the limitations reported in previous studies. It was possible to distinguish four kinds of flow patterns: laminar, wavy laminar, plugged, and spiral. The first variation in flow pattern from laminar to wavy laminar flow found between 0.8 and 0.39, and a second variation in flow pattern found from wavy laminar flow to plug or slug flow between 0.15 and 0.05. For the refrigerant conditions, the condensation temperature did not affect the flow pattern. When using R-134a, the inner tube diameter had no effect on the flow pattern. Change occurs with R-600a as inner diameter was increased.\",\"PeriodicalId\":37460,\"journal\":{\"name\":\"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences\",\"volume\":\"135 39\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37934/arfmts.117.2.105115\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Chemical Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Research in Fluid Mechanics and Thermal Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37934/arfmts.117.2.105115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemical Engineering","Score":null,"Total":0}
The Change of Flow Pattern from Stratified to Stratified-Wavy for Condensation in Wire on Tube Heat Exchangers
Flow patterns inside wire-on-tube condensers with different refrigerant mass flow rates were studied in a theoretical study. In this study, tubes with diameters of 3.25 mm (3/16"), 4.83 mm (1/4") and 6.29 mm (5/16") were used. R-134a and R-600a cooling fluids were used at condensing temperatures of 54.4°C, 45°C, and 35°C. The results of this study were obtained using Equal Equation Solver (EES) software. The proposed model was able to predict the type of refrigerant flow pattern based on the limitations reported in previous studies. It was possible to distinguish four kinds of flow patterns: laminar, wavy laminar, plugged, and spiral. The first variation in flow pattern from laminar to wavy laminar flow found between 0.8 and 0.39, and a second variation in flow pattern found from wavy laminar flow to plug or slug flow between 0.15 and 0.05. For the refrigerant conditions, the condensation temperature did not affect the flow pattern. When using R-134a, the inner tube diameter had no effect on the flow pattern. Change occurs with R-600a as inner diameter was increased.
期刊介绍:
This journal welcomes high-quality original contributions on experimental, computational, and physical aspects of fluid mechanics and thermal sciences relevant to engineering or the environment, multiphase and microscale flows, microscale electronic and mechanical systems; medical and biological systems; and thermal and flow control in both the internal and external environment.