ELISA检测活性污泥中轮状病毒的初步评价。

F Agbalika, M Wullenweber, J Prévot
{"title":"ELISA检测活性污泥中轮状病毒的初步评价。","authors":"F Agbalika,&nbsp;M Wullenweber,&nbsp;J Prévot","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Samples of activated sludge were taken in three different treatment plants near Nancy (France) and in West Berlin (F.R.G.), and were investigated for their content of rotaviruses. After elution with beef extract (0.25%, pH 7.3) and ultrasonication, the samples were concentrated by protamine flocculation and, in a few cases, in parallel by ultracentrifugation. A commercially available ELISA test kit (Rotazyme, Abbott Diagnostics) was routinely used for rotavirus detection. Although both the Rotazyme and a laboratory-designed ELISA gave positive results for the suldge concentrates, confirmation with a blocking test and electron microscope (EM) was negative in all cases so far investigated. Therefore, the exclusive use of ELISA cannot be recommended for similar investigations as it may lead to false positive results. In this light, an additional verification step with neutralizing antibodies should be included by the ELISA kits' manufacturers to enable a quick confirmation of the user's results.</p>","PeriodicalId":77820,"journal":{"name":"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene","volume":"180 5-6","pages":"534-9"},"PeriodicalIF":0.0000,"publicationDate":"1985-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary evaluation of the ELISA as a tool for the detection of rotaviruses in activated sewage sludge.\",\"authors\":\"F Agbalika,&nbsp;M Wullenweber,&nbsp;J Prévot\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Samples of activated sludge were taken in three different treatment plants near Nancy (France) and in West Berlin (F.R.G.), and were investigated for their content of rotaviruses. After elution with beef extract (0.25%, pH 7.3) and ultrasonication, the samples were concentrated by protamine flocculation and, in a few cases, in parallel by ultracentrifugation. A commercially available ELISA test kit (Rotazyme, Abbott Diagnostics) was routinely used for rotavirus detection. Although both the Rotazyme and a laboratory-designed ELISA gave positive results for the suldge concentrates, confirmation with a blocking test and electron microscope (EM) was negative in all cases so far investigated. Therefore, the exclusive use of ELISA cannot be recommended for similar investigations as it may lead to false positive results. In this light, an additional verification step with neutralizing antibodies should be included by the ELISA kits' manufacturers to enable a quick confirmation of the user's results.</p>\",\"PeriodicalId\":77820,\"journal\":{\"name\":\"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene\",\"volume\":\"180 5-6\",\"pages\":\"534-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zentralblatt fur Bakteriologie, Mikrobiologie und Hygiene. 1. Abt. Originale B, Hygiene","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在南希(法国)和西柏林(F.R.G.)附近的三个不同的处理厂采集了活性污泥样本,并对其轮状病毒含量进行了调查。样品经牛肉提取物(0.25%,pH 7.3)和超声波洗脱后,用鱼精蛋白絮凝浓缩,少数情况下用超离心平行浓缩。市售的ELISA检测试剂盒(Rotazyme,雅培诊断公司)常规用于轮状病毒检测。虽然Rotazyme和实验室设计的ELISA对污泥浓缩物的检测结果都是阳性的,但到目前为止,通过阻断试验和电子显微镜(EM)确认的所有病例都是阴性的。因此,不建议在类似的调查中单独使用ELISA,因为它可能导致假阳性结果。在这种情况下,ELISA试剂盒的制造商应该包括一个额外的中和抗体验证步骤,以便能够快速确认用户的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preliminary evaluation of the ELISA as a tool for the detection of rotaviruses in activated sewage sludge.

Samples of activated sludge were taken in three different treatment plants near Nancy (France) and in West Berlin (F.R.G.), and were investigated for their content of rotaviruses. After elution with beef extract (0.25%, pH 7.3) and ultrasonication, the samples were concentrated by protamine flocculation and, in a few cases, in parallel by ultracentrifugation. A commercially available ELISA test kit (Rotazyme, Abbott Diagnostics) was routinely used for rotavirus detection. Although both the Rotazyme and a laboratory-designed ELISA gave positive results for the suldge concentrates, confirmation with a blocking test and electron microscope (EM) was negative in all cases so far investigated. Therefore, the exclusive use of ELISA cannot be recommended for similar investigations as it may lead to false positive results. In this light, an additional verification step with neutralizing antibodies should be included by the ELISA kits' manufacturers to enable a quick confirmation of the user's results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信