求助PDF
{"title":"为伽马能谱中的闪烁探测器开发基于 FPGA 的脉冲高度分析仪","authors":"Vo Hong Hai","doi":"10.1002/tee.24131","DOIUrl":null,"url":null,"abstract":"<p>This study presents the development of a Pulse Height Analyzer (PHA) using an FPGA-based hardware platform, specifically the National Instruments MyRIO embedded device, for radiation detectors. Electronic pulses generated by the detector when exposed to radiation are triggered, digitized, and transferred to a data buffer. A pulse height analysis tool categorizes these pulses and stores pulse-height information in registers or channels, enabling the construction of a pulse-height distribution. The data of pulse-height distribution is then recorded on a computer via a user-friendly interface. The Pulse Height Analyzer was implemented using a 3-inch by 3-inch NaI(Tl) scintillation detector for gamma energy measurements, employing standard radioisotopes Na-22 and Co-60. Gamma energy spectra were acquired and analyzed. Our results demonstrate that the achieved energy resolution is comparable to that of the commercial Pulse Height Analyzers, such as EASY-MCA 2K, a product of AMETEK Inc. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.</p>","PeriodicalId":13435,"journal":{"name":"IEEJ Transactions on Electrical and Electronic Engineering","volume":"19 10","pages":"1737-1742"},"PeriodicalIF":1.0000,"publicationDate":"2024-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an FPGA-Based Pulse-Height Analyzer for Scintillation Detectors in Gamma Energy Spectroscopy\",\"authors\":\"Vo Hong Hai\",\"doi\":\"10.1002/tee.24131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This study presents the development of a Pulse Height Analyzer (PHA) using an FPGA-based hardware platform, specifically the National Instruments MyRIO embedded device, for radiation detectors. Electronic pulses generated by the detector when exposed to radiation are triggered, digitized, and transferred to a data buffer. A pulse height analysis tool categorizes these pulses and stores pulse-height information in registers or channels, enabling the construction of a pulse-height distribution. The data of pulse-height distribution is then recorded on a computer via a user-friendly interface. The Pulse Height Analyzer was implemented using a 3-inch by 3-inch NaI(Tl) scintillation detector for gamma energy measurements, employing standard radioisotopes Na-22 and Co-60. Gamma energy spectra were acquired and analyzed. Our results demonstrate that the achieved energy resolution is comparable to that of the commercial Pulse Height Analyzers, such as EASY-MCA 2K, a product of AMETEK Inc. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.</p>\",\"PeriodicalId\":13435,\"journal\":{\"name\":\"IEEJ Transactions on Electrical and Electronic Engineering\",\"volume\":\"19 10\",\"pages\":\"1737-1742\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEJ Transactions on Electrical and Electronic Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/tee.24131\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEJ Transactions on Electrical and Electronic Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/tee.24131","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
引用
批量引用