Jonas Schandorph Kaalund Jensen, Ina Hunnerup Jørgensen, Niels Henrik Buus, Jens Dam Jensen, Christian Daugaard Peters
{"title":"血液透析患者透析液碳酸氢盐浓度过低与过高对血液动力学的影响。","authors":"Jonas Schandorph Kaalund Jensen, Ina Hunnerup Jørgensen, Niels Henrik Buus, Jens Dam Jensen, Christian Daugaard Peters","doi":"10.1111/hdi.13162","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim of this study was to perform a detailed comparison of high and low dialysate bicarbonate in terms of blood pressure, intradialytic hemodynamic parameters, orthostatic blood pressure, and electrolytes.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Fifteen hemodialysis patients were examined in a single-blind, randomized, controlled, crossover study. Participants underwent a 4-h hemodialysis session with dialysate bicarbonate concentration of 30 or 38 mmol/L with 1 week between interventions. Blood pressure was monitored throughout hemodialysis, while cardiac output, total peripheral resistance, stroke volume, and central blood volume were assessed with ultrasound dilution technique (Transonic). Orthostatic blood pressure was measured pre- and post-hemodialysis.</p>\n </section>\n \n <section>\n \n <h3> Findings</h3>\n \n <p>With similar ultrafiltration (UF) volume (2.6 L), systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate compared to low dialysate bicarbonate; the mean (95% confidence interval) between treatment differences in SBP were: 8 (−4; 20) mmHg (end of hemodialysis) and 7 (0; 15) mmHg (post-hemodialysis). Stroke volume decreased whereas total peripheral resistance increased significantly more during high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment differences: Stroke volume: 12 (1; 23) mL; Total peripheral resistance: −2.9 (−5.3; −0.5) mmHg/(L/min). Cardiac output tended to decrease more with high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment difference 0.7 (0.0; 1.4) L/min. High dialysate bicarbonate caused alkalosis, hypocalcemia, and lower plasma potassium, whereas patients remained normocalcemic with normal pH during low dialysate bicarbonate. Orthostatic blood pressure response after dialysis did not differ significantly.</p>\n </section>\n \n <section>\n \n <h3> Discussion</h3>\n \n <p>The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.</p>\n </section>\n </div>","PeriodicalId":12815,"journal":{"name":"Hemodialysis International","volume":"28 3","pages":"290-303"},"PeriodicalIF":1.2000,"publicationDate":"2024-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/hdi.13162","citationCount":"0","resultStr":"{\"title\":\"Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients\",\"authors\":\"Jonas Schandorph Kaalund Jensen, Ina Hunnerup Jørgensen, Niels Henrik Buus, Jens Dam Jensen, Christian Daugaard Peters\",\"doi\":\"10.1111/hdi.13162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim of this study was to perform a detailed comparison of high and low dialysate bicarbonate in terms of blood pressure, intradialytic hemodynamic parameters, orthostatic blood pressure, and electrolytes.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Fifteen hemodialysis patients were examined in a single-blind, randomized, controlled, crossover study. Participants underwent a 4-h hemodialysis session with dialysate bicarbonate concentration of 30 or 38 mmol/L with 1 week between interventions. Blood pressure was monitored throughout hemodialysis, while cardiac output, total peripheral resistance, stroke volume, and central blood volume were assessed with ultrasound dilution technique (Transonic). Orthostatic blood pressure was measured pre- and post-hemodialysis.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Findings</h3>\\n \\n <p>With similar ultrafiltration (UF) volume (2.6 L), systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate compared to low dialysate bicarbonate; the mean (95% confidence interval) between treatment differences in SBP were: 8 (−4; 20) mmHg (end of hemodialysis) and 7 (0; 15) mmHg (post-hemodialysis). Stroke volume decreased whereas total peripheral resistance increased significantly more during high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment differences: Stroke volume: 12 (1; 23) mL; Total peripheral resistance: −2.9 (−5.3; −0.5) mmHg/(L/min). Cardiac output tended to decrease more with high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment difference 0.7 (0.0; 1.4) L/min. High dialysate bicarbonate caused alkalosis, hypocalcemia, and lower plasma potassium, whereas patients remained normocalcemic with normal pH during low dialysate bicarbonate. Orthostatic blood pressure response after dialysis did not differ significantly.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Discussion</h3>\\n \\n <p>The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.</p>\\n </section>\\n </div>\",\"PeriodicalId\":12815,\"journal\":{\"name\":\"Hemodialysis International\",\"volume\":\"28 3\",\"pages\":\"290-303\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/hdi.13162\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hemodialysis International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/hdi.13162\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hemodialysis International","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/hdi.13162","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients
Introduction
Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim of this study was to perform a detailed comparison of high and low dialysate bicarbonate in terms of blood pressure, intradialytic hemodynamic parameters, orthostatic blood pressure, and electrolytes.
Methods
Fifteen hemodialysis patients were examined in a single-blind, randomized, controlled, crossover study. Participants underwent a 4-h hemodialysis session with dialysate bicarbonate concentration of 30 or 38 mmol/L with 1 week between interventions. Blood pressure was monitored throughout hemodialysis, while cardiac output, total peripheral resistance, stroke volume, and central blood volume were assessed with ultrasound dilution technique (Transonic). Orthostatic blood pressure was measured pre- and post-hemodialysis.
Findings
With similar ultrafiltration (UF) volume (2.6 L), systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate compared to low dialysate bicarbonate; the mean (95% confidence interval) between treatment differences in SBP were: 8 (−4; 20) mmHg (end of hemodialysis) and 7 (0; 15) mmHg (post-hemodialysis). Stroke volume decreased whereas total peripheral resistance increased significantly more during high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment differences: Stroke volume: 12 (1; 23) mL; Total peripheral resistance: −2.9 (−5.3; −0.5) mmHg/(L/min). Cardiac output tended to decrease more with high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment difference 0.7 (0.0; 1.4) L/min. High dialysate bicarbonate caused alkalosis, hypocalcemia, and lower plasma potassium, whereas patients remained normocalcemic with normal pH during low dialysate bicarbonate. Orthostatic blood pressure response after dialysis did not differ significantly.
Discussion
The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.
期刊介绍:
Hemodialysis International was originally an annual publication containing the Proceedings of the International Symposium on Hemodialysis held in conjunction with the Annual Dialysis Conference. Since 2003, Hemodialysis International is published quarterly and contains original papers on clinical and experimental topics related to dialysis in addition to the Annual Dialysis Conference supplement. This journal is a must-have for nephrologists, nurses, and technicians worldwide. Quarterly issues of Hemodialysis International are included with your membership to the International Society for Hemodialysis.
The journal contains original articles, review articles, and commentary to keep readers completely updated in the field of hemodialysis. Edited by international and multidisciplinary experts, Hemodialysis International disseminates critical information in the field.