不同空间配置的外固定器在粉碎性骺端骨折损伤控制手术中的比较研究

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Yousof Mohandes, Mohammad Tahami, Amir R. Askari
{"title":"不同空间配置的外固定器在粉碎性骺端骨折损伤控制手术中的比较研究","authors":"Yousof Mohandes, Mohammad Tahami, Amir R. Askari","doi":"10.1007/s40997-024-00777-8","DOIUrl":null,"url":null,"abstract":"<p>Fractures in the lower extremities are sometimes accompanied by severe damage, so definitive treatments with extensive surgical exposure are impractical. Extensive traumatization and swelling of surrounding tissue often dictate the use of external fixators as a temporary treatment for immediate stabilization of compound fractures. External fixation offers a variety of possible spatial configurations. Adequate fracture stabilization demands a good understanding of the stiffness, strength, sustainability, and tilting of external fixators of different frames. An improper frame can result in nonunion, malunion, delayed healing, and bone re-fracture, some of which are indications for revision surgery. This study employs a numerical approach to assess the stiffness, stress distribution, pin loosening, and interfragmentary displacement in different configurations of external fixators applied to a comminuted fracture in the diaphyseal region of the tibia. Unilateral fixators with single and double rods, bilateral, biplanar, and triangular frames with and without end cross-links are different configurations examined in-silico. Results show that the triangular frame with cross-links exhibits the stiffest, strongest, and most sustainable construct in axial, bending, and torsion modes. Except for the torsion mode, adding the end cross-links does little to increase the stiffness and strength of biplanar and triangular frames. Moreover, doubling the rod considerably improves construct stiffness and strength under axial compression load while appearing to be less superior in torsional stiffness and pin loosening. Furthermore, the bilateral frame demonstrates the most uniform displacement across the fracture gap. The results of this study could be used for preoperative planning of diaphyseal fracture management with external fixators.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Study of External Fixators With Different Spatial Configurations in the Damage Control Surgery of Comminuted Diaphyseal Fracture\",\"authors\":\"Yousof Mohandes, Mohammad Tahami, Amir R. Askari\",\"doi\":\"10.1007/s40997-024-00777-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Fractures in the lower extremities are sometimes accompanied by severe damage, so definitive treatments with extensive surgical exposure are impractical. Extensive traumatization and swelling of surrounding tissue often dictate the use of external fixators as a temporary treatment for immediate stabilization of compound fractures. External fixation offers a variety of possible spatial configurations. Adequate fracture stabilization demands a good understanding of the stiffness, strength, sustainability, and tilting of external fixators of different frames. An improper frame can result in nonunion, malunion, delayed healing, and bone re-fracture, some of which are indications for revision surgery. This study employs a numerical approach to assess the stiffness, stress distribution, pin loosening, and interfragmentary displacement in different configurations of external fixators applied to a comminuted fracture in the diaphyseal region of the tibia. Unilateral fixators with single and double rods, bilateral, biplanar, and triangular frames with and without end cross-links are different configurations examined in-silico. Results show that the triangular frame with cross-links exhibits the stiffest, strongest, and most sustainable construct in axial, bending, and torsion modes. Except for the torsion mode, adding the end cross-links does little to increase the stiffness and strength of biplanar and triangular frames. Moreover, doubling the rod considerably improves construct stiffness and strength under axial compression load while appearing to be less superior in torsional stiffness and pin loosening. Furthermore, the bilateral frame demonstrates the most uniform displacement across the fracture gap. The results of this study could be used for preoperative planning of diaphyseal fracture management with external fixators.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s40997-024-00777-8\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s40997-024-00777-8","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

下肢骨折有时会伴有严重的损伤,因此进行大面积手术暴露的明确治疗是不切实际的。大面积的创伤和周围组织的肿胀往往要求使用外固定器作为临时治疗手段,以立即稳定复合骨折。外固定器可提供多种可能的空间结构。要充分稳定骨折,就必须充分了解不同框架的外固定器的硬度、强度、可持续性和倾斜度。不适当的框架会导致骨折不愈合、错位、延迟愈合和骨再骨折,其中一些是翻修手术的适应症。本研究采用数值方法评估了应用于胫骨骺区粉碎性骨折的不同结构外固定器的刚度、应力分布、针松动和节间位移。单侧外固定器包括单杆和双杆、双侧外固定器、双平面外固定器和带或不带末端交叉连接的三角形外固定器,这些都是在实验室中检测的不同配置。结果表明,在轴向、弯曲和扭转模式下,带有交叉连接的三角形框架表现出最坚硬、最强和最持久的结构。除扭转模式外,增加端部交联对提高双平面和三角形框架的刚度和强度几乎没有影响。此外,增加一倍的杆件可显著提高轴向压缩载荷下的结构刚度和强度,但在扭转刚度和销钉松动方面的优势似乎较小。此外,双侧框架在骨折间隙处的位移最为均匀。这项研究的结果可用于使用外固定器治疗骺端骨折的术前规划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparative Study of External Fixators With Different Spatial Configurations in the Damage Control Surgery of Comminuted Diaphyseal Fracture

Comparative Study of External Fixators With Different Spatial Configurations in the Damage Control Surgery of Comminuted Diaphyseal Fracture

Fractures in the lower extremities are sometimes accompanied by severe damage, so definitive treatments with extensive surgical exposure are impractical. Extensive traumatization and swelling of surrounding tissue often dictate the use of external fixators as a temporary treatment for immediate stabilization of compound fractures. External fixation offers a variety of possible spatial configurations. Adequate fracture stabilization demands a good understanding of the stiffness, strength, sustainability, and tilting of external fixators of different frames. An improper frame can result in nonunion, malunion, delayed healing, and bone re-fracture, some of which are indications for revision surgery. This study employs a numerical approach to assess the stiffness, stress distribution, pin loosening, and interfragmentary displacement in different configurations of external fixators applied to a comminuted fracture in the diaphyseal region of the tibia. Unilateral fixators with single and double rods, bilateral, biplanar, and triangular frames with and without end cross-links are different configurations examined in-silico. Results show that the triangular frame with cross-links exhibits the stiffest, strongest, and most sustainable construct in axial, bending, and torsion modes. Except for the torsion mode, adding the end cross-links does little to increase the stiffness and strength of biplanar and triangular frames. Moreover, doubling the rod considerably improves construct stiffness and strength under axial compression load while appearing to be less superior in torsional stiffness and pin loosening. Furthermore, the bilateral frame demonstrates the most uniform displacement across the fracture gap. The results of this study could be used for preoperative planning of diaphyseal fracture management with external fixators.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信