评估 810 和 980 nm 两种波长的二极管激光器与两种不同的光束轮廓对漂白过程中牙齿变色的效果:一项实验研究

Q2 Medicine
Laser therapy Pub Date : 2024-05-20 DOI:10.4081/ltj.2024.387
Mahshid Saffarpour, Sajjad Gerami, Nastaran Parviz, N. Chiniforush
{"title":"评估 810 和 980 nm 两种波长的二极管激光器与两种不同的光束轮廓对漂白过程中牙齿变色的效果:一项实验研究","authors":"Mahshid Saffarpour, Sajjad Gerami, Nastaran Parviz, N. Chiniforush","doi":"10.4081/ltj.2024.387","DOIUrl":null,"url":null,"abstract":"Teeth color has a significant impact on facial aesthetics. Tooth bleaching is the safest way to lighten the color of your teeth. Today, hydrogen peroxide is the most commonly used bleaching agent. The diode laser is one of the light sources that speeds up the bleaching process. One of the laser beam features is the laser beam profile, which depicts the distribution of laser intensity across the beam section. The goal of this study is to look into the effectiveness of Gaussian and Flat top beam profiles on tooth shade using two diode laser wavelengths of 810 and 980 nm in the tooth bleaching process. Fifty human anterior and premolar teeth were extracted and placed in a tea and coffee solution for three weeks before being divided into five groups. The first group did not receive laser radiation because 40% hydrogen peroxide was used; in the second and third groups, the profile of the flat top beam and the wavelength were 810 and 980 nm, respectively; and in the fourth and fifth groups, the wavelength of the Gaussian beam profile was 810 and 980 nm. The shade of the samples before and after bleaching was measured with a CIELab-based spectrophotometer, and the results were analyzed using one-way ANOVA and Tukey’s multiple comparison test. All bleaching methods resulted in a significant change in tooth color (ΔE>3.3). There was a significant difference in average shade changes across groups (P<0.001). The highest degree of shade change was observed in two groups of lasers with a wavelength of 980 nm and profiles of Flat top beam (ΔE=5.35) and Gaussian (ΔE=5.02). There were no differences between the remaining groups. We conclude that the 980 nm wavelength produces a greater shade change than the 810 nm wavelength and chemical method. The diode laser’s 810 nm wavelength has no effect on the shade of teeth.","PeriodicalId":17981,"journal":{"name":"Laser therapy","volume":"27 16","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating the effectiveness of two wavelengths of 810 and 980 nm Diode laser with two different beam profiles on tooth discoloration in bleaching: an experimental study\",\"authors\":\"Mahshid Saffarpour, Sajjad Gerami, Nastaran Parviz, N. Chiniforush\",\"doi\":\"10.4081/ltj.2024.387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Teeth color has a significant impact on facial aesthetics. Tooth bleaching is the safest way to lighten the color of your teeth. Today, hydrogen peroxide is the most commonly used bleaching agent. The diode laser is one of the light sources that speeds up the bleaching process. One of the laser beam features is the laser beam profile, which depicts the distribution of laser intensity across the beam section. The goal of this study is to look into the effectiveness of Gaussian and Flat top beam profiles on tooth shade using two diode laser wavelengths of 810 and 980 nm in the tooth bleaching process. Fifty human anterior and premolar teeth were extracted and placed in a tea and coffee solution for three weeks before being divided into five groups. The first group did not receive laser radiation because 40% hydrogen peroxide was used; in the second and third groups, the profile of the flat top beam and the wavelength were 810 and 980 nm, respectively; and in the fourth and fifth groups, the wavelength of the Gaussian beam profile was 810 and 980 nm. The shade of the samples before and after bleaching was measured with a CIELab-based spectrophotometer, and the results were analyzed using one-way ANOVA and Tukey’s multiple comparison test. All bleaching methods resulted in a significant change in tooth color (ΔE>3.3). There was a significant difference in average shade changes across groups (P<0.001). The highest degree of shade change was observed in two groups of lasers with a wavelength of 980 nm and profiles of Flat top beam (ΔE=5.35) and Gaussian (ΔE=5.02). There were no differences between the remaining groups. We conclude that the 980 nm wavelength produces a greater shade change than the 810 nm wavelength and chemical method. The diode laser’s 810 nm wavelength has no effect on the shade of teeth.\",\"PeriodicalId\":17981,\"journal\":{\"name\":\"Laser therapy\",\"volume\":\"27 16\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laser therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/ltj.2024.387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/ltj.2024.387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

牙齿颜色对面部美观有很大影响。牙齿漂白是淡化牙齿颜色最安全的方法。如今,过氧化氢是最常用的漂白剂。二极管激光是加速漂白过程的光源之一。激光光束的特征之一是激光光束轮廓,它描述了激光强度在光束截面上的分布。本研究的目的是利用波长分别为 810 和 980 纳米的两种二极管激光,研究高斯和平顶光束轮廓在牙齿漂白过程中对牙齿色泽的影响。50 颗人类前磨牙和前臼齿被拔出,在茶和咖啡溶液中浸泡三周后被分为五组。第一组没有接受激光照射,因为使用的是 40% 的过氧化氢;第二组和第三组的平顶光束轮廓和波长分别为 810 纳米和 980 纳米;第四组和第五组的高斯光束轮廓波长分别为 810 纳米和 980 纳米。使用基于 CIELab 的分光光度计测量漂白前后样品的色度,并使用单因素方差分析和 Tukey's 多重比较检验对结果进行分析。所有漂白方法都能显著改变牙齿颜色(ΔE>3.3)。各组的平均色泽变化有明显差异(P<0.001)。两组波长为 980 nm、轮廓为平顶光束(ΔE=5.35)和高斯光束(ΔE=5.02)的激光器观察到的色泽变化程度最高。其余各组之间没有差异。我们的结论是,980 纳米波长比 810 纳米波长和化学方法产生的色调变化更大。二极管激光器的 810 纳米波长对牙齿色泽没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating the effectiveness of two wavelengths of 810 and 980 nm Diode laser with two different beam profiles on tooth discoloration in bleaching: an experimental study
Teeth color has a significant impact on facial aesthetics. Tooth bleaching is the safest way to lighten the color of your teeth. Today, hydrogen peroxide is the most commonly used bleaching agent. The diode laser is one of the light sources that speeds up the bleaching process. One of the laser beam features is the laser beam profile, which depicts the distribution of laser intensity across the beam section. The goal of this study is to look into the effectiveness of Gaussian and Flat top beam profiles on tooth shade using two diode laser wavelengths of 810 and 980 nm in the tooth bleaching process. Fifty human anterior and premolar teeth were extracted and placed in a tea and coffee solution for three weeks before being divided into five groups. The first group did not receive laser radiation because 40% hydrogen peroxide was used; in the second and third groups, the profile of the flat top beam and the wavelength were 810 and 980 nm, respectively; and in the fourth and fifth groups, the wavelength of the Gaussian beam profile was 810 and 980 nm. The shade of the samples before and after bleaching was measured with a CIELab-based spectrophotometer, and the results were analyzed using one-way ANOVA and Tukey’s multiple comparison test. All bleaching methods resulted in a significant change in tooth color (ΔE>3.3). There was a significant difference in average shade changes across groups (P<0.001). The highest degree of shade change was observed in two groups of lasers with a wavelength of 980 nm and profiles of Flat top beam (ΔE=5.35) and Gaussian (ΔE=5.02). There were no differences between the remaining groups. We conclude that the 980 nm wavelength produces a greater shade change than the 810 nm wavelength and chemical method. The diode laser’s 810 nm wavelength has no effect on the shade of teeth.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Laser therapy
Laser therapy Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信