利用带可调电感滤波器的电源进行有源并联补偿

IF 1.2 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Łukasz Ciepliński, Adam Gulczyński
{"title":"利用带可调电感滤波器的电源进行有源并联补偿","authors":"Łukasz Ciepliński, Adam Gulczyński","doi":"10.24425/aee.2024.149920","DOIUrl":null,"url":null,"abstract":"Increasing numbers of devices of various types are now connected to power lines. Their nonlinear nature harms the operation of the lines, as the line voltage is distorted from a sine wave, which causes disturbances in the operation of other loads. This study proposes a method of active parallel compensation that can be realised using a power supply. The proposed device is a dual-function system: it supplies the load connected to its DC link, and operates as a parallel active filter. This kind of device, with a relatively low value of the rated output power, could be implemented in electrical systems to provide distributed compensation. The second novel aspect of this work is the use of a tunable inductive filter, which is included at the input of the power electronics controlled current source and forms a main part of the power supply. The use of this tunable inductive filter increases the frequency response of the current source, while at the same time, in the quasi-steady state of power supply operation, the pulse modulation component of the input current source remains at a minimum level. This paper discusses the structure of an electrical system with the proposed power supply and the rules of operation for the system, and presents test results based on both a simulation and a laboratory model of the system.","PeriodicalId":45464,"journal":{"name":"Archives of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Active parallel compensation using a power supply with a tunable inductive filter\",\"authors\":\"Łukasz Ciepliński, Adam Gulczyński\",\"doi\":\"10.24425/aee.2024.149920\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Increasing numbers of devices of various types are now connected to power lines. Their nonlinear nature harms the operation of the lines, as the line voltage is distorted from a sine wave, which causes disturbances in the operation of other loads. This study proposes a method of active parallel compensation that can be realised using a power supply. The proposed device is a dual-function system: it supplies the load connected to its DC link, and operates as a parallel active filter. This kind of device, with a relatively low value of the rated output power, could be implemented in electrical systems to provide distributed compensation. The second novel aspect of this work is the use of a tunable inductive filter, which is included at the input of the power electronics controlled current source and forms a main part of the power supply. The use of this tunable inductive filter increases the frequency response of the current source, while at the same time, in the quasi-steady state of power supply operation, the pulse modulation component of the input current source remains at a minimum level. This paper discusses the structure of an electrical system with the proposed power supply and the rules of operation for the system, and presents test results based on both a simulation and a laboratory model of the system.\",\"PeriodicalId\":45464,\"journal\":{\"name\":\"Archives of Electrical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/aee.2024.149920\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/aee.2024.149920","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

目前,越来越多的各类设备与电力线相连。它们的非线性特性会损害线路的运行,因为线路电压会从正弦波失真,从而对其他负载的运行造成干扰。本研究提出了一种可使用电源实现有源并联补偿的方法。所提出的装置是一个双功能系统:它既能为与其直流链路相连的负载供电,又能作为并联有源滤波器工作。这种装置的额定输出功率值相对较低,可用于电力系统,提供分布式补偿。这项工作的第二个新颖之处在于使用了可调电感滤波器,它包含在电力电子控制电流源的输入端,并构成电源的主要部分。使用这种可调电感滤波器可提高电流源的频率响应,同时,在电源工作的准稳定状态下,输入电流源的脉冲调制分量保持在最低水平。本文讨论了带有拟议电源的电气系统的结构和系统的运行规则,并介绍了基于系统模拟和实验室模型的测试结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Active parallel compensation using a power supply with a tunable inductive filter
Increasing numbers of devices of various types are now connected to power lines. Their nonlinear nature harms the operation of the lines, as the line voltage is distorted from a sine wave, which causes disturbances in the operation of other loads. This study proposes a method of active parallel compensation that can be realised using a power supply. The proposed device is a dual-function system: it supplies the load connected to its DC link, and operates as a parallel active filter. This kind of device, with a relatively low value of the rated output power, could be implemented in electrical systems to provide distributed compensation. The second novel aspect of this work is the use of a tunable inductive filter, which is included at the input of the power electronics controlled current source and forms a main part of the power supply. The use of this tunable inductive filter increases the frequency response of the current source, while at the same time, in the quasi-steady state of power supply operation, the pulse modulation component of the input current source remains at a minimum level. This paper discusses the structure of an electrical system with the proposed power supply and the rules of operation for the system, and presents test results based on both a simulation and a laboratory model of the system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Archives of Electrical Engineering
Archives of Electrical Engineering ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
2.40
自引率
53.80%
发文量
0
审稿时长
18 weeks
期刊介绍: The journal publishes original papers in the field of electrical engineering which covers, but not limited to, the following scope: - Control - Electrical machines and transformers - Electrical & magnetic fields problems - Electric traction - Electro heat - Fuel cells, micro machines, hybrid vehicles - Nondestructive testing & Nondestructive evaluation - Electrical power engineering - Power electronics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信