Thomas J Joyce, Göksu Kandemir, David Warwick, Daniel J Brown
{"title":"碳纤维金属加固聚醚醚酮 Motec 腕关节的短期体内性能研究:外植体分析。","authors":"Thomas J Joyce, Göksu Kandemir, David Warwick, Daniel J Brown","doi":"10.1177/17531934241249919","DOIUrl":null,"url":null,"abstract":"<p><p>Total wrist arthroplasty (TWA) aims to restore pain-free motion to diseased joints. One such TWA, the Motec, has demonstrated good results with acceptable complication rates. It has recently been suggested that the metal-on-carbon fibre reinforced poly ether ether ketone (Mo-CFR-PEEK) version of the Motec TWA be implanted instead of the metal-on-metal version. An explant analysis was undertaken on seven Motec Mo-CFR-PEEK TWAs, revised for a variety of reasons, after a mean time of 2 years in vivo. Compared to a new Motec implant, five of the explanted metal heads and three of the CFR-PEEK cups became smoother in vivo, suggesting self-polishing and negative skewness, indicating some material loss in vivo. Two explanted cups showed indentation marks on their rims and one of these was from component impingement with embedded metallic debris. In the short-term, the articulating surfaces of Motec Mo-CFR-PEEK TWAs did not show major damage.<b>Level of evidence:</b> IV.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":" ","pages":"114-119"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11699702/pdf/","citationCount":"0","resultStr":"{\"title\":\"Investigation of the short-term in vivo performance of metal-on-carbon fibre reinforced poly ether ether ketone Motec wrists: an explant analysis.\",\"authors\":\"Thomas J Joyce, Göksu Kandemir, David Warwick, Daniel J Brown\",\"doi\":\"10.1177/17531934241249919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Total wrist arthroplasty (TWA) aims to restore pain-free motion to diseased joints. One such TWA, the Motec, has demonstrated good results with acceptable complication rates. It has recently been suggested that the metal-on-carbon fibre reinforced poly ether ether ketone (Mo-CFR-PEEK) version of the Motec TWA be implanted instead of the metal-on-metal version. An explant analysis was undertaken on seven Motec Mo-CFR-PEEK TWAs, revised for a variety of reasons, after a mean time of 2 years in vivo. Compared to a new Motec implant, five of the explanted metal heads and three of the CFR-PEEK cups became smoother in vivo, suggesting self-polishing and negative skewness, indicating some material loss in vivo. Two explanted cups showed indentation marks on their rims and one of these was from component impingement with embedded metallic debris. In the short-term, the articulating surfaces of Motec Mo-CFR-PEEK TWAs did not show major damage.<b>Level of evidence:</b> IV.</p>\",\"PeriodicalId\":94237,\"journal\":{\"name\":\"The Journal of hand surgery, European volume\",\"volume\":\" \",\"pages\":\"114-119\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11699702/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of hand surgery, European volume\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934241249919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934241249919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
全腕关节置换术(TWA)旨在恢复病变关节的无痛运动。其中,Motec 全腕关节成形术效果良好,并发症发生率在可接受范围内。最近,有人建议植入碳纤维增强聚醚醚酮(Mo-CFR-PEEK)金属对碳纤维的Motec TWA,而不是金属对金属的Motec TWA。我们对七种因各种原因而改良的 Motec Mo-CFR-PEEK TWA 进行了外植体分析,这些 TWA 在体内的平均植入时间为两年。与新的Motec种植体相比,5个被取出的金属头和3个CFR-PEEK杯在体内变得更加光滑,这表明它们在体内进行了自抛光和负偏斜,这表明它们在体内有一定的材料损失。两个被取出的杯体边缘有压痕,其中一个是由于嵌入金属碎片的组件撞击造成的。在短期内,Motec Mo-CFR-PEEK TWA 的铰接表面没有出现重大损坏:证据等级:IV.
Investigation of the short-term in vivo performance of metal-on-carbon fibre reinforced poly ether ether ketone Motec wrists: an explant analysis.
Total wrist arthroplasty (TWA) aims to restore pain-free motion to diseased joints. One such TWA, the Motec, has demonstrated good results with acceptable complication rates. It has recently been suggested that the metal-on-carbon fibre reinforced poly ether ether ketone (Mo-CFR-PEEK) version of the Motec TWA be implanted instead of the metal-on-metal version. An explant analysis was undertaken on seven Motec Mo-CFR-PEEK TWAs, revised for a variety of reasons, after a mean time of 2 years in vivo. Compared to a new Motec implant, five of the explanted metal heads and three of the CFR-PEEK cups became smoother in vivo, suggesting self-polishing and negative skewness, indicating some material loss in vivo. Two explanted cups showed indentation marks on their rims and one of these was from component impingement with embedded metallic debris. In the short-term, the articulating surfaces of Motec Mo-CFR-PEEK TWAs did not show major damage.Level of evidence: IV.