{"title":"利用尸体股骨进行可注射双相磷酸钙骨水泥增强股骨近端抗旋转钉(PFNA)治疗两处转子间骨折的可行性生物力学研究。","authors":"Ponthep Tangkanjanavelukul, Paritat Thaitalay, Sawitri Srisuwan, Pongpayap Petchwisai, Pornsak Thasanaraphan, Yotakarn Saramas, Kittiphong Nimarkorn, Woranat Warojananulak, Chaosuan Kanchanomai, Sirirat Tubsungnoen Rattanachan","doi":"10.1088/2057-1976/ad4e3c","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the feasibility of the femoral bone after fixation using biphasic calcium phosphate cement-augmentation of the proximal femoral nail antirotation (PFNA) compared with PFNA without cement. This study presented to compare the stiffness, fatigue testing, and compressive strength between stable (AO31-A2.1) and unstable (AO31-A3.3) intertrochanteric fractures treated by cement augmented PFNA of the cadaveric femoral. Biphasic calcium phosphate cement was injected to align and compatible with PFNA and the reconstructive procedure was monitored the cement placement using x-ray imaging during operation. The testing demonstrated that the cement could be injected through a small needle (13 G, 16 cm length, 1.8 mm inner diameter) within a suitable operating time. The feasibility study of the biomechanical testing was divided into three tests: stiffness test, fatigue cyclic load, and compression test. The results showed that the cement-augmented specimens exhibited higher stiffness than the control specimens without cement. The cement-augmented specimens also showed lower strain energy during the fatigue test, resulting in higher compressive strength (4730.7 N) compared to the control specimens (3857.4 N). There is a correlation between BMD and fracture load and the increase in compression load of the cement-augmented femoral compared to the controls as well as an increase in strain energy of fatigue cyclic testing was found. Biphasic calcium phosphate cement-augmented of the PFNA biomechanically enhanced the cut-out resistance in intertrochanteric fracture. This procedure is especially efficient for unstable intertrochanteric fracture suggesting the potential benefits of using biphasic calcium phosphate cement in medical applications.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility biomechanical study of injectable Biphasic Calcium Phosphate bone cement augmentation of the proximal femoral nail antirotation (PFNA) for the treatment of two intertrochanteric fractures using cadaveric femur.\",\"authors\":\"Ponthep Tangkanjanavelukul, Paritat Thaitalay, Sawitri Srisuwan, Pongpayap Petchwisai, Pornsak Thasanaraphan, Yotakarn Saramas, Kittiphong Nimarkorn, Woranat Warojananulak, Chaosuan Kanchanomai, Sirirat Tubsungnoen Rattanachan\",\"doi\":\"10.1088/2057-1976/ad4e3c\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluated the feasibility of the femoral bone after fixation using biphasic calcium phosphate cement-augmentation of the proximal femoral nail antirotation (PFNA) compared with PFNA without cement. This study presented to compare the stiffness, fatigue testing, and compressive strength between stable (AO31-A2.1) and unstable (AO31-A3.3) intertrochanteric fractures treated by cement augmented PFNA of the cadaveric femoral. Biphasic calcium phosphate cement was injected to align and compatible with PFNA and the reconstructive procedure was monitored the cement placement using x-ray imaging during operation. The testing demonstrated that the cement could be injected through a small needle (13 G, 16 cm length, 1.8 mm inner diameter) within a suitable operating time. The feasibility study of the biomechanical testing was divided into three tests: stiffness test, fatigue cyclic load, and compression test. The results showed that the cement-augmented specimens exhibited higher stiffness than the control specimens without cement. The cement-augmented specimens also showed lower strain energy during the fatigue test, resulting in higher compressive strength (4730.7 N) compared to the control specimens (3857.4 N). There is a correlation between BMD and fracture load and the increase in compression load of the cement-augmented femoral compared to the controls as well as an increase in strain energy of fatigue cyclic testing was found. Biphasic calcium phosphate cement-augmented of the PFNA biomechanically enhanced the cut-out resistance in intertrochanteric fracture. This procedure is especially efficient for unstable intertrochanteric fracture suggesting the potential benefits of using biphasic calcium phosphate cement in medical applications.</p>\",\"PeriodicalId\":8896,\"journal\":{\"name\":\"Biomedical Physics & Engineering Express\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Physics & Engineering Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2057-1976/ad4e3c\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad4e3c","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Feasibility biomechanical study of injectable Biphasic Calcium Phosphate bone cement augmentation of the proximal femoral nail antirotation (PFNA) for the treatment of two intertrochanteric fractures using cadaveric femur.
This study evaluated the feasibility of the femoral bone after fixation using biphasic calcium phosphate cement-augmentation of the proximal femoral nail antirotation (PFNA) compared with PFNA without cement. This study presented to compare the stiffness, fatigue testing, and compressive strength between stable (AO31-A2.1) and unstable (AO31-A3.3) intertrochanteric fractures treated by cement augmented PFNA of the cadaveric femoral. Biphasic calcium phosphate cement was injected to align and compatible with PFNA and the reconstructive procedure was monitored the cement placement using x-ray imaging during operation. The testing demonstrated that the cement could be injected through a small needle (13 G, 16 cm length, 1.8 mm inner diameter) within a suitable operating time. The feasibility study of the biomechanical testing was divided into three tests: stiffness test, fatigue cyclic load, and compression test. The results showed that the cement-augmented specimens exhibited higher stiffness than the control specimens without cement. The cement-augmented specimens also showed lower strain energy during the fatigue test, resulting in higher compressive strength (4730.7 N) compared to the control specimens (3857.4 N). There is a correlation between BMD and fracture load and the increase in compression load of the cement-augmented femoral compared to the controls as well as an increase in strain energy of fatigue cyclic testing was found. Biphasic calcium phosphate cement-augmented of the PFNA biomechanically enhanced the cut-out resistance in intertrochanteric fracture. This procedure is especially efficient for unstable intertrochanteric fracture suggesting the potential benefits of using biphasic calcium phosphate cement in medical applications.
期刊介绍:
BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.