心房机械弥散与导管消融术后心房颤动复发的关系:ASTRA-AF 试验研究的结果。

IF 3.8 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Clinical Research in Cardiology Pub Date : 2025-01-01 Epub Date: 2024-05-21 DOI:10.1007/s00392-024-02435-0
Dorit Knappe, Julia Vogler, Jessica Weimann, Victor Banas, Sevenai Yildirim, Felix Memenga, Juliana Senftinger, Laura Keil, Djemail Ismaili, Moritz Nies, Andreas Rillig, Stephan Willems, Stefan Blankenberg, Paulus Kirchhof, Andreas Metzner, Christoph Sinning
{"title":"心房机械弥散与导管消融术后心房颤动复发的关系:ASTRA-AF 试验研究的结果。","authors":"Dorit Knappe, Julia Vogler, Jessica Weimann, Victor Banas, Sevenai Yildirim, Felix Memenga, Juliana Senftinger, Laura Keil, Djemail Ismaili, Moritz Nies, Andreas Rillig, Stephan Willems, Stefan Blankenberg, Paulus Kirchhof, Andreas Metzner, Christoph Sinning","doi":"10.1007/s00392-024-02435-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation.</p><p><strong>Methods: </strong>The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal (n = 88) or persistent AF (n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence.</p><p><strong>Results: </strong>Kaplan-Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase.</p><p><strong>Conclusion: </strong>Atrial mechanical dispersion was associated with recurrent AF.</p>","PeriodicalId":10474,"journal":{"name":"Clinical Research in Cardiology","volume":" ","pages":"103-111"},"PeriodicalIF":3.8000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11772373/pdf/","citationCount":"0","resultStr":"{\"title\":\"Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study.\",\"authors\":\"Dorit Knappe, Julia Vogler, Jessica Weimann, Victor Banas, Sevenai Yildirim, Felix Memenga, Juliana Senftinger, Laura Keil, Djemail Ismaili, Moritz Nies, Andreas Rillig, Stephan Willems, Stefan Blankenberg, Paulus Kirchhof, Andreas Metzner, Christoph Sinning\",\"doi\":\"10.1007/s00392-024-02435-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation.</p><p><strong>Methods: </strong>The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal (n = 88) or persistent AF (n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence.</p><p><strong>Results: </strong>Kaplan-Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase.</p><p><strong>Conclusion: </strong>Atrial mechanical dispersion was associated with recurrent AF.</p>\",\"PeriodicalId\":10474,\"journal\":{\"name\":\"Clinical Research in Cardiology\",\"volume\":\" \",\"pages\":\"103-111\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11772373/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Research in Cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00392-024-02435-0\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Research in Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00392-024-02435-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:对于有症状的药物难治性心房颤动(房颤)患者来说,通过导管消融来控制心律是一种重要的治疗方法。以峰值应变时间标准差(SD-TPS)测量的心房机械离散度与导管消融术后房颤复发的风险有关:研究队列前瞻性地纳入了 n = 132 例连续的阵发性房颤(n = 88 例)或持续性房颤(n = 44 例)患者,这些患者接受了新的肺静脉隔离术(PVI),并随访了 1 年。我们将左心房(LA)容积、LA射血分数、SD-TPS和左心室整体纵向应变以及临床变量(性别、年龄和房颤类型)与房颤复发联系起来:Kaplan-Meier曲线显示,SD-TPS越高,房颤复发率越高,计算的临界值为38.6毫秒。单变量和多变量 Cox 回归分析表明,SD-TPS 与房颤复发的相关性最高,每增加 10 毫秒,HR 为 1.05(95% CI,1.01;1.09,p = 0.01);每增加 10 毫秒,HR 为 1.05(95% CI,1.01;1.09,p = 0.02)。在包括临床变量年龄、性别和阵发性或持续性房颤类型的模型附加分析中,SD-TPS仅显示出一种趋势,在调整协变量后,SD-TPS每增加10毫秒的HR为1.04 (95% CI, 0.99; 1.09, p = 0.09):结论:心房机械弥散与复发性房颤有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study.

Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study.

Aims: For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation.

Methods: The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal (n = 88) or persistent AF (n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence.

Results: Kaplan-Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase.

Conclusion: Atrial mechanical dispersion was associated with recurrent AF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Research in Cardiology
Clinical Research in Cardiology 医学-心血管系统
CiteScore
11.40
自引率
4.00%
发文量
140
审稿时长
4-8 weeks
期刊介绍: Clinical Research in Cardiology is an international journal for clinical cardiovascular research. It provides a forum for original and review articles as well as critical perspective articles. Articles are only accepted if they meet stringent scientific standards and have undergone peer review. The journal regularly receives articles from the field of clinical cardiology, angiology, as well as heart and vascular surgery. As the official journal of the German Cardiac Society, it gives a current and competent survey on the diagnosis and therapy of heart and vascular diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信