{"title":"评估粘度对高速冷却剂泵性能的影响","authors":"Dongcheng Wang, Yandong Gu, Christopher Stephen, Wenpeng Zhao, Qingfeng Ji","doi":"10.1063/5.0208753","DOIUrl":null,"url":null,"abstract":"The high-speed coolant pump facilitates thermal regulation in electric vehicle components, including batteries and motors, by circulating an ethylene glycol solution. This commonly used circulating fluid exhibits a notable negative correlation with temperature in terms of viscosity. Numerical simulations investigate the transient dynamics of a high-speed coolant pump operating at 6000 rpm, driving coolant flow at various temperatures. A high-speed coolant pump test rig is established, and the performance is evaluated under different temperature conditions. The numerical simulations at different temperatures align well with the experimental outcomes. Decreasing temperatures, from 100 to −20 °C, lead to reduced pump head and efficiency due to increased viscosity. Specifically, at a flow rate of 30 L/min, head decreases by 40.03% and efficiency by 44.19%. With escalating viscosity, the best efficiency point shifts toward lower flow rates. Notable impacts on both disk efficiency and hydraulic efficiency are observed due to viscosity fluctuations. It exerts minimal influence on volumetric efficiency at elevated flow rates but has a substantial impact on volumetric efficiency at lower flow rates. Increased fluid viscosity causes uneven pressure distribution within the pump, altering velocity profiles within the impeller. High-viscosity fluids tend to form large-scale vortex structures around the blades, reducing the thrust exerted by the blades on the fluid. Higher viscosity results in larger vortex structures around the blades, reducing thrust and increasing fluid frictional resistance. The study findings provide valuable insights for the advancement of high-efficiency, energy-saving, high-speed coolant pumps tailored for electric vehicles.","PeriodicalId":509470,"journal":{"name":"Physics of Fluids","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of viscosity effects on high-speed coolant pump performance\",\"authors\":\"Dongcheng Wang, Yandong Gu, Christopher Stephen, Wenpeng Zhao, Qingfeng Ji\",\"doi\":\"10.1063/5.0208753\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The high-speed coolant pump facilitates thermal regulation in electric vehicle components, including batteries and motors, by circulating an ethylene glycol solution. This commonly used circulating fluid exhibits a notable negative correlation with temperature in terms of viscosity. Numerical simulations investigate the transient dynamics of a high-speed coolant pump operating at 6000 rpm, driving coolant flow at various temperatures. A high-speed coolant pump test rig is established, and the performance is evaluated under different temperature conditions. The numerical simulations at different temperatures align well with the experimental outcomes. Decreasing temperatures, from 100 to −20 °C, lead to reduced pump head and efficiency due to increased viscosity. Specifically, at a flow rate of 30 L/min, head decreases by 40.03% and efficiency by 44.19%. With escalating viscosity, the best efficiency point shifts toward lower flow rates. Notable impacts on both disk efficiency and hydraulic efficiency are observed due to viscosity fluctuations. It exerts minimal influence on volumetric efficiency at elevated flow rates but has a substantial impact on volumetric efficiency at lower flow rates. Increased fluid viscosity causes uneven pressure distribution within the pump, altering velocity profiles within the impeller. High-viscosity fluids tend to form large-scale vortex structures around the blades, reducing the thrust exerted by the blades on the fluid. Higher viscosity results in larger vortex structures around the blades, reducing thrust and increasing fluid frictional resistance. The study findings provide valuable insights for the advancement of high-efficiency, energy-saving, high-speed coolant pumps tailored for electric vehicles.\",\"PeriodicalId\":509470,\"journal\":{\"name\":\"Physics of Fluids\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physics of Fluids\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0208753\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics of Fluids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0208753","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

高速冷却剂泵通过循环乙二醇溶液,促进电动汽车组件(包括电池和电机)的热调节。这种常用的循环液在粘度方面与温度呈明显的负相关。数值模拟研究了转速为 6000 rpm 的高速冷却剂泵在不同温度下驱动冷却剂流动的瞬态动力学。建立了一个高速冷却剂泵试验台,并对其在不同温度条件下的性能进行了评估。不同温度下的数值模拟结果与实验结果非常吻合。温度从 100 ℃ 降到 -20 ℃ 时,由于粘度增加,泵的扬程和效率降低。具体来说,在流量为 30 升/分钟时,扬程降低了 40.03%,效率降低了 44.19%。随着粘度的增加,最佳效率点向低流速转移。粘度波动对圆盘效率和水力效率都有显著影响。在流速较高时,粘度对容积效率的影响很小,但在流速较低时,粘度对容积效率的影响很大。流体粘度增加会导致泵内压力分布不均,从而改变叶轮内的速度曲线。高粘度流体往往会在叶片周围形成大规模涡旋结构,从而降低叶片对流体施加的推力。粘度越高,叶片周围的涡旋结构越大,推力越小,流体摩擦阻力越大。研究结果为开发电动汽车专用的高效、节能、高速冷却剂泵提供了宝贵的启示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of viscosity effects on high-speed coolant pump performance
The high-speed coolant pump facilitates thermal regulation in electric vehicle components, including batteries and motors, by circulating an ethylene glycol solution. This commonly used circulating fluid exhibits a notable negative correlation with temperature in terms of viscosity. Numerical simulations investigate the transient dynamics of a high-speed coolant pump operating at 6000 rpm, driving coolant flow at various temperatures. A high-speed coolant pump test rig is established, and the performance is evaluated under different temperature conditions. The numerical simulations at different temperatures align well with the experimental outcomes. Decreasing temperatures, from 100 to −20 °C, lead to reduced pump head and efficiency due to increased viscosity. Specifically, at a flow rate of 30 L/min, head decreases by 40.03% and efficiency by 44.19%. With escalating viscosity, the best efficiency point shifts toward lower flow rates. Notable impacts on both disk efficiency and hydraulic efficiency are observed due to viscosity fluctuations. It exerts minimal influence on volumetric efficiency at elevated flow rates but has a substantial impact on volumetric efficiency at lower flow rates. Increased fluid viscosity causes uneven pressure distribution within the pump, altering velocity profiles within the impeller. High-viscosity fluids tend to form large-scale vortex structures around the blades, reducing the thrust exerted by the blades on the fluid. Higher viscosity results in larger vortex structures around the blades, reducing thrust and increasing fluid frictional resistance. The study findings provide valuable insights for the advancement of high-efficiency, energy-saving, high-speed coolant pumps tailored for electric vehicles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信