墙壁距离对五孔探针测量的影响

IF 1.3 Q2 ENGINEERING, AEROSPACE
Adrien Vasseur, Nicolas Binder, Fabrizio Fontaneto, Jean-Louis Champion
{"title":"墙壁距离对五孔探针测量的影响","authors":"Adrien Vasseur, Nicolas Binder, Fabrizio Fontaneto, Jean-Louis Champion","doi":"10.3390/ijtpp9020016","DOIUrl":null,"url":null,"abstract":"Wall proximity affects the accuracy of pressure probe measurements with a particularly strong impact on multi-hole probes. The wall-related evolution of the calibration of two hemispheric L-shaped 3D-printed five-hole probes was investigated in a low-speed wind tunnel. Pressure measurements and 2D particle image velocimetry were performed. The wall proximity causes the probe to measure a flow diverging from the wall, whereas the boundary layer causes the probe to measure a velocity directed towards the wall. Both angular calibration coefficients are affected in different manners. The error in angle measurement can reach 7°. These errors can be treated as calibration information. Acceleration caused by blockage is not the main reason for the errors. Methods to perform measurements closer to the wall are suggested.","PeriodicalId":36626,"journal":{"name":"International Journal of Turbomachinery, Propulsion and Power","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wall-Proximity Effects on Five-Hole Probe Measurements\",\"authors\":\"Adrien Vasseur, Nicolas Binder, Fabrizio Fontaneto, Jean-Louis Champion\",\"doi\":\"10.3390/ijtpp9020016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Wall proximity affects the accuracy of pressure probe measurements with a particularly strong impact on multi-hole probes. The wall-related evolution of the calibration of two hemispheric L-shaped 3D-printed five-hole probes was investigated in a low-speed wind tunnel. Pressure measurements and 2D particle image velocimetry were performed. The wall proximity causes the probe to measure a flow diverging from the wall, whereas the boundary layer causes the probe to measure a velocity directed towards the wall. Both angular calibration coefficients are affected in different manners. The error in angle measurement can reach 7°. These errors can be treated as calibration information. Acceleration caused by blockage is not the main reason for the errors. Methods to perform measurements closer to the wall are suggested.\",\"PeriodicalId\":36626,\"journal\":{\"name\":\"International Journal of Turbomachinery, Propulsion and Power\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-05-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Turbomachinery, Propulsion and Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/ijtpp9020016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, AEROSPACE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Turbomachinery, Propulsion and Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/ijtpp9020016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
引用次数: 0

摘要

靠近墙壁会影响压力探头的测量精度,对多孔探头的影响尤其大。我们在低速风洞中研究了两个半球形 L 形 3D 打印五孔探头的校准与墙壁相关的演变。进行了压力测量和二维粒子图像测速。靠近壁面会导致探头测量偏离壁面的气流,而边界层会导致探头测量朝向壁面的速度。两种角度校准系数受到不同方式的影响。角度测量误差可达 7°。这些误差可作为校准信息处理。堵塞造成的加速度并不是产生误差的主要原因。建议采用更靠近墙壁的方法进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wall-Proximity Effects on Five-Hole Probe Measurements
Wall proximity affects the accuracy of pressure probe measurements with a particularly strong impact on multi-hole probes. The wall-related evolution of the calibration of two hemispheric L-shaped 3D-printed five-hole probes was investigated in a low-speed wind tunnel. Pressure measurements and 2D particle image velocimetry were performed. The wall proximity causes the probe to measure a flow diverging from the wall, whereas the boundary layer causes the probe to measure a velocity directed towards the wall. Both angular calibration coefficients are affected in different manners. The error in angle measurement can reach 7°. These errors can be treated as calibration information. Acceleration caused by blockage is not the main reason for the errors. Methods to perform measurements closer to the wall are suggested.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
21.40%
发文量
29
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信