Gregg D Simonson, Amy B Criego, Tadej Battelino, Anders L Carlson, Pratik Choudhary, Sylvia Franc, Dana Gershenoff, George Grunberger, Irl B Hirsch, Diana Isaacs, Mary L Johnson, David Kerr, Davida F Kruger, Chantal Mathieu, Thomas W Martens, Revital Nimri, Sean M Oser, Anne L Peters, Ruth S Weinstock, Eugene E Wright, Carol H Wysham, Richard M Bergenstal
{"title":"专家小组对用于连接胰岛素笔的标准化非卧床血糖曲线报告的建议。","authors":"Gregg D Simonson, Amy B Criego, Tadej Battelino, Anders L Carlson, Pratik Choudhary, Sylvia Franc, Dana Gershenoff, George Grunberger, Irl B Hirsch, Diana Isaacs, Mary L Johnson, David Kerr, Davida F Kruger, Chantal Mathieu, Thomas W Martens, Revital Nimri, Sean M Oser, Anne L Peters, Ruth S Weinstock, Eugene E Wright, Carol H Wysham, Richard M Bergenstal","doi":"10.1089/dia.2024.0107","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background</i></b>: Connected insulin pens capture data on insulin dosing/timing and can integrate with continuous glucose monitoring (CGM) devices with essential insulin and glucose metrics combined into a single platform. Standardization of connected insulin pen reports is desirable to enhance clinical utility with a single report. <b><i>Methods</i></b>: An international expert panel was convened to develop a standardized connected insulin pen report incorporating insulin and glucose metrics into a single report containing clinically useful information. An extensive literature review and identification of examples of current connected insulin pen reports were performed serving as the basis for creation of a draft of a standardized connected insulin pen report. The expert panel participated in three virtual standardization meetings and online surveys. <b><i>Results</i></b>: The <i>Ambulatory Glucose Profile (AGP) Report: Connected Insulin Pen</i> brings all clinically relevant CGM-derived glucose and connected insulin pen metrics into a single simplified two-page report. The first page contains the time in ranges bar, summary of key insulin and glucose metrics, the AGP curve, and detailed basal (long-acting) insulin assessment. The second page contains the bolus (mealtime and correction) insulin assessment periods with information on meal timing, insulin-to-carbohydrate ratio, average bolus insulin dose, and number of days with bolus doses recorded. The report's second page contains daily glucose profiles with an overlay of the timing and amount of basal and bolus insulin administered. <b><i>Conclusion</i></b>: The <i>AGP Report: Connected Insulin Pen</i> is a standardized clinically useful report that should be considered by companies developing connected pen technology as part of their system reporting/output.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":"814-822"},"PeriodicalIF":5.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Expert Panel Recommendations for a Standardized Ambulatory Glucose Profile Report for Connected Insulin Pens.\",\"authors\":\"Gregg D Simonson, Amy B Criego, Tadej Battelino, Anders L Carlson, Pratik Choudhary, Sylvia Franc, Dana Gershenoff, George Grunberger, Irl B Hirsch, Diana Isaacs, Mary L Johnson, David Kerr, Davida F Kruger, Chantal Mathieu, Thomas W Martens, Revital Nimri, Sean M Oser, Anne L Peters, Ruth S Weinstock, Eugene E Wright, Carol H Wysham, Richard M Bergenstal\",\"doi\":\"10.1089/dia.2024.0107\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background</i></b>: Connected insulin pens capture data on insulin dosing/timing and can integrate with continuous glucose monitoring (CGM) devices with essential insulin and glucose metrics combined into a single platform. Standardization of connected insulin pen reports is desirable to enhance clinical utility with a single report. <b><i>Methods</i></b>: An international expert panel was convened to develop a standardized connected insulin pen report incorporating insulin and glucose metrics into a single report containing clinically useful information. An extensive literature review and identification of examples of current connected insulin pen reports were performed serving as the basis for creation of a draft of a standardized connected insulin pen report. The expert panel participated in three virtual standardization meetings and online surveys. <b><i>Results</i></b>: The <i>Ambulatory Glucose Profile (AGP) Report: Connected Insulin Pen</i> brings all clinically relevant CGM-derived glucose and connected insulin pen metrics into a single simplified two-page report. The first page contains the time in ranges bar, summary of key insulin and glucose metrics, the AGP curve, and detailed basal (long-acting) insulin assessment. The second page contains the bolus (mealtime and correction) insulin assessment periods with information on meal timing, insulin-to-carbohydrate ratio, average bolus insulin dose, and number of days with bolus doses recorded. The report's second page contains daily glucose profiles with an overlay of the timing and amount of basal and bolus insulin administered. <b><i>Conclusion</i></b>: The <i>AGP Report: Connected Insulin Pen</i> is a standardized clinically useful report that should be considered by companies developing connected pen technology as part of their system reporting/output.</p>\",\"PeriodicalId\":11159,\"journal\":{\"name\":\"Diabetes technology & therapeutics\",\"volume\":\" \",\"pages\":\"814-822\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes technology & therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/dia.2024.0107\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0107","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Expert Panel Recommendations for a Standardized Ambulatory Glucose Profile Report for Connected Insulin Pens.
Background: Connected insulin pens capture data on insulin dosing/timing and can integrate with continuous glucose monitoring (CGM) devices with essential insulin and glucose metrics combined into a single platform. Standardization of connected insulin pen reports is desirable to enhance clinical utility with a single report. Methods: An international expert panel was convened to develop a standardized connected insulin pen report incorporating insulin and glucose metrics into a single report containing clinically useful information. An extensive literature review and identification of examples of current connected insulin pen reports were performed serving as the basis for creation of a draft of a standardized connected insulin pen report. The expert panel participated in three virtual standardization meetings and online surveys. Results: The Ambulatory Glucose Profile (AGP) Report: Connected Insulin Pen brings all clinically relevant CGM-derived glucose and connected insulin pen metrics into a single simplified two-page report. The first page contains the time in ranges bar, summary of key insulin and glucose metrics, the AGP curve, and detailed basal (long-acting) insulin assessment. The second page contains the bolus (mealtime and correction) insulin assessment periods with information on meal timing, insulin-to-carbohydrate ratio, average bolus insulin dose, and number of days with bolus doses recorded. The report's second page contains daily glucose profiles with an overlay of the timing and amount of basal and bolus insulin administered. Conclusion: The AGP Report: Connected Insulin Pen is a standardized clinically useful report that should be considered by companies developing connected pen technology as part of their system reporting/output.
期刊介绍:
Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.