基于螺栓连接的预制混凝土梁柱连接有限元分析

Jingbin Xu, Hao Li, Yu Zhang
{"title":"基于螺栓连接的预制混凝土梁柱连接有限元分析","authors":"Jingbin Xu, Hao Li, Yu Zhang","doi":"10.1002/tal.2130","DOIUrl":null,"url":null,"abstract":"SummaryA novel proposal for an assembled bolted joint between a precast reinforced concrete beam and column is presented in this paper. In order to evaluate the behavior of the joint, a comprehensive experiment was carried out on a full‐scale precast concrete beam‐column joint based on bolted connection subjected to pseudo‐static loading. The experiment aims to investigate the failure mode, load carrying capacity, and energy dissipation characteristics of the joint. To further understand the performance of the joint, a finite element model was developed using ABAQUS. The difference in failure mode and ultimate bearing capacity between the bolted joints and cast‐in‐situ joints were analyzed in conjunction with the experimental results. Moreover, the impact of various parameters on the performance of the bolted joints was quantified. The characteristics of the bolted joints, such as the span‐depth ratio, reinforcement ratio of the beam, the stirrup ratio at the beam‐column junction, T‐end length, and the bolt strength grade, were meticulously analyzed through an examination of bearing capacity curve, stiffness degradation patterns, and energy dissipation capability. The results show that, in comparison with the traditional cast‐in‐situ joints, the damage failure extent exhibited by the bolted joints is notably smaller, thereby rendering it more advantageous for seismic restoration and replacement. Furthermore, the span‐depth ratio, reinforcement ratio of the beam, and the stirrup ratio have a greater influence on the seismic performance of bolted joints than the T‐end length and bolt strength grade.","PeriodicalId":501238,"journal":{"name":"The Structural Design of Tall and Special Buildings","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Finite element analysis of precast concrete beam‐column joint based on bolt connection\",\"authors\":\"Jingbin Xu, Hao Li, Yu Zhang\",\"doi\":\"10.1002/tal.2130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"SummaryA novel proposal for an assembled bolted joint between a precast reinforced concrete beam and column is presented in this paper. In order to evaluate the behavior of the joint, a comprehensive experiment was carried out on a full‐scale precast concrete beam‐column joint based on bolted connection subjected to pseudo‐static loading. The experiment aims to investigate the failure mode, load carrying capacity, and energy dissipation characteristics of the joint. To further understand the performance of the joint, a finite element model was developed using ABAQUS. The difference in failure mode and ultimate bearing capacity between the bolted joints and cast‐in‐situ joints were analyzed in conjunction with the experimental results. Moreover, the impact of various parameters on the performance of the bolted joints was quantified. The characteristics of the bolted joints, such as the span‐depth ratio, reinforcement ratio of the beam, the stirrup ratio at the beam‐column junction, T‐end length, and the bolt strength grade, were meticulously analyzed through an examination of bearing capacity curve, stiffness degradation patterns, and energy dissipation capability. The results show that, in comparison with the traditional cast‐in‐situ joints, the damage failure extent exhibited by the bolted joints is notably smaller, thereby rendering it more advantageous for seismic restoration and replacement. Furthermore, the span‐depth ratio, reinforcement ratio of the beam, and the stirrup ratio have a greater influence on the seismic performance of bolted joints than the T‐end length and bolt strength grade.\",\"PeriodicalId\":501238,\"journal\":{\"name\":\"The Structural Design of Tall and Special Buildings\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Structural Design of Tall and Special Buildings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/tal.2130\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Structural Design of Tall and Special Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/tal.2130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要 本文提出了预制钢筋混凝土梁和柱之间装配式螺栓连接的新方案。为了评估该连接件的行为,我们对基于螺栓连接的全尺寸预制混凝土梁柱连接件进行了假静力加载综合实验。实验旨在研究接头的失效模式、承载能力和耗能特性。为进一步了解接头的性能,使用 ABAQUS 建立了有限元模型。结合实验结果,分析了螺栓连接和现浇连接在失效模式和极限承载能力方面的差异。此外,还量化了各种参数对螺栓连接性能的影响。通过研究承载力曲线、刚度退化模式和耗能能力,细致分析了螺栓连接的特性,如跨深比、梁的配筋比、梁柱交界处的箍筋比、T 端长度和螺栓强度等级。结果表明,与传统的现浇连接相比,螺栓连接的破坏程度明显较小,因此在抗震修复和替换方面更具优势。此外,与 T 端长度和螺栓强度等级相比,跨深比、梁的配筋率和箍筋率对螺栓连接抗震性能的影响更大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Finite element analysis of precast concrete beam‐column joint based on bolt connection
SummaryA novel proposal for an assembled bolted joint between a precast reinforced concrete beam and column is presented in this paper. In order to evaluate the behavior of the joint, a comprehensive experiment was carried out on a full‐scale precast concrete beam‐column joint based on bolted connection subjected to pseudo‐static loading. The experiment aims to investigate the failure mode, load carrying capacity, and energy dissipation characteristics of the joint. To further understand the performance of the joint, a finite element model was developed using ABAQUS. The difference in failure mode and ultimate bearing capacity between the bolted joints and cast‐in‐situ joints were analyzed in conjunction with the experimental results. Moreover, the impact of various parameters on the performance of the bolted joints was quantified. The characteristics of the bolted joints, such as the span‐depth ratio, reinforcement ratio of the beam, the stirrup ratio at the beam‐column junction, T‐end length, and the bolt strength grade, were meticulously analyzed through an examination of bearing capacity curve, stiffness degradation patterns, and energy dissipation capability. The results show that, in comparison with the traditional cast‐in‐situ joints, the damage failure extent exhibited by the bolted joints is notably smaller, thereby rendering it more advantageous for seismic restoration and replacement. Furthermore, the span‐depth ratio, reinforcement ratio of the beam, and the stirrup ratio have a greater influence on the seismic performance of bolted joints than the T‐end length and bolt strength grade.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信