{"title":"基于压缩传感容积插值屏气检查的 DCE-MRI 甲状腺结节鉴别诊断:可行性研究","authors":"Junhao Huang , Daihong Liu , Jiao Chen , Xiaoxia Wang , Lin Tang , Jing Zhang , Yong Tan , Xiaosong Lan , Ting Yin , Dominik Nickel , Jian Wu , Jiuquan Zhang","doi":"10.1016/j.mri.2024.05.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>To explore the potential and performance of quantitative and semi-quantitative parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on compressed sensing volumetric interpolated breath-hold (CS-VIBE) examination in the differential diagnosis of thyroid nodules.</p></div><div><h3>Materials and methods</h3><p>A total of 208 patients with 259 thyroid nodules scheduled for surgery operation were prospectively recruited. All participants underwent routine and DCE-MRI. DCE-MRI quantitative parameters [Ktrans, Kep, Ve], semi-quantitative parameters [wash-in, wash-out, time to peak (TTP), arrival time (AT), peak enhancement intensity (PEI), and initial area under curve in 60 s (iAUC)] and time-intensity curve (TIC) types were analyzed. Differential diagnostic performances were assessed using area under the receiver operating characteristic curve (AUC) and compared with the Delong test.</p></div><div><h3>Results</h3><p>Ktrans, Kep, Ve, wash-in, wash-out, PEI and iAUC were statistically significantly different between malignant and benign nodules (<em>P</em> < 0.001). Among these parameters, ROC analysis revealed that Ktrans showed the highest diagnostic performance in the differentiation of benign and malignant nodules, followed by wash-in. ROC analysis also revealed that Ktrans achieved the best diagnostic performance for distinguishing papillary thyroid carcinoma (PTC) from non-PTC, follicular adenoma (FA) from non-FA, nodular goiter (NG) from non-NG, with AUC values of 0.854, 0.895 and 0.609, respectively. Type III curve is frequently observed in benign thyroid nodules, accounting for 77.4% (82/106). While malignant nodules are more common in type II, accounting for 57.5% (88/153).</p></div><div><h3>Conclusion</h3><p>Thyroid examination using CS-VIBE based DCE-MRI is a feasible, non-invasive method to identify benign and malignant thyroid nodules and pathological types.</p></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"111 ","pages":"Pages 138-147"},"PeriodicalIF":2.1000,"publicationDate":"2024-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Differential diagnosis of thyroid nodules by DCE-MRI based on compressed sensing volumetric interpolated breath-hold examination: A feasibility study\",\"authors\":\"Junhao Huang , Daihong Liu , Jiao Chen , Xiaoxia Wang , Lin Tang , Jing Zhang , Yong Tan , Xiaosong Lan , Ting Yin , Dominik Nickel , Jian Wu , Jiuquan Zhang\",\"doi\":\"10.1016/j.mri.2024.05.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><p>To explore the potential and performance of quantitative and semi-quantitative parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on compressed sensing volumetric interpolated breath-hold (CS-VIBE) examination in the differential diagnosis of thyroid nodules.</p></div><div><h3>Materials and methods</h3><p>A total of 208 patients with 259 thyroid nodules scheduled for surgery operation were prospectively recruited. All participants underwent routine and DCE-MRI. DCE-MRI quantitative parameters [Ktrans, Kep, Ve], semi-quantitative parameters [wash-in, wash-out, time to peak (TTP), arrival time (AT), peak enhancement intensity (PEI), and initial area under curve in 60 s (iAUC)] and time-intensity curve (TIC) types were analyzed. Differential diagnostic performances were assessed using area under the receiver operating characteristic curve (AUC) and compared with the Delong test.</p></div><div><h3>Results</h3><p>Ktrans, Kep, Ve, wash-in, wash-out, PEI and iAUC were statistically significantly different between malignant and benign nodules (<em>P</em> < 0.001). Among these parameters, ROC analysis revealed that Ktrans showed the highest diagnostic performance in the differentiation of benign and malignant nodules, followed by wash-in. ROC analysis also revealed that Ktrans achieved the best diagnostic performance for distinguishing papillary thyroid carcinoma (PTC) from non-PTC, follicular adenoma (FA) from non-FA, nodular goiter (NG) from non-NG, with AUC values of 0.854, 0.895 and 0.609, respectively. Type III curve is frequently observed in benign thyroid nodules, accounting for 77.4% (82/106). While malignant nodules are more common in type II, accounting for 57.5% (88/153).</p></div><div><h3>Conclusion</h3><p>Thyroid examination using CS-VIBE based DCE-MRI is a feasible, non-invasive method to identify benign and malignant thyroid nodules and pathological types.</p></div>\",\"PeriodicalId\":18165,\"journal\":{\"name\":\"Magnetic resonance imaging\",\"volume\":\"111 \",\"pages\":\"Pages 138-147\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-05-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0730725X24001553\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X24001553","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Differential diagnosis of thyroid nodules by DCE-MRI based on compressed sensing volumetric interpolated breath-hold examination: A feasibility study
Objectives
To explore the potential and performance of quantitative and semi-quantitative parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on compressed sensing volumetric interpolated breath-hold (CS-VIBE) examination in the differential diagnosis of thyroid nodules.
Materials and methods
A total of 208 patients with 259 thyroid nodules scheduled for surgery operation were prospectively recruited. All participants underwent routine and DCE-MRI. DCE-MRI quantitative parameters [Ktrans, Kep, Ve], semi-quantitative parameters [wash-in, wash-out, time to peak (TTP), arrival time (AT), peak enhancement intensity (PEI), and initial area under curve in 60 s (iAUC)] and time-intensity curve (TIC) types were analyzed. Differential diagnostic performances were assessed using area under the receiver operating characteristic curve (AUC) and compared with the Delong test.
Results
Ktrans, Kep, Ve, wash-in, wash-out, PEI and iAUC were statistically significantly different between malignant and benign nodules (P < 0.001). Among these parameters, ROC analysis revealed that Ktrans showed the highest diagnostic performance in the differentiation of benign and malignant nodules, followed by wash-in. ROC analysis also revealed that Ktrans achieved the best diagnostic performance for distinguishing papillary thyroid carcinoma (PTC) from non-PTC, follicular adenoma (FA) from non-FA, nodular goiter (NG) from non-NG, with AUC values of 0.854, 0.895 and 0.609, respectively. Type III curve is frequently observed in benign thyroid nodules, accounting for 77.4% (82/106). While malignant nodules are more common in type II, accounting for 57.5% (88/153).
Conclusion
Thyroid examination using CS-VIBE based DCE-MRI is a feasible, non-invasive method to identify benign and malignant thyroid nodules and pathological types.
期刊介绍:
Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.