二氧化碳和碘造影剂在出血模型中的体外渗漏比较。

IF 1.2 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Ryoichi Kitamura, Kazuhiro Yoshida, Takaaki Maruhashi, Satoshi Tamura, Yutaro Kurihara, Koyo Suzuki, Yasushi Asari
{"title":"二氧化碳和碘造影剂在出血模型中的体外渗漏比较。","authors":"Ryoichi Kitamura, Kazuhiro Yoshida, Takaaki Maruhashi, Satoshi Tamura, Yutaro Kurihara, Koyo Suzuki, Yasushi Asari","doi":"10.1186/s42155-024-00457-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We aimed to compare the hydrodynamic values of carbon dioxide (CO<sub>2</sub>) and iodine contrast media for bleeding detection using an in vitro model.</p><p><strong>Materials and methods: </strong>We created a bleeding model with large and small wounds in simulated blood vessels. We connected a syringe to the bleeding model and the blood pressure transducer, filling the circuit with CO<sub>2</sub> and iodine contrast media. The syringe's piston was pressed, and the flow rate and intravascular pressure of the CO<sub>2</sub> and iodine contrast media leaking from the bleeding model were measured. We compared each leaked contrast medium's volume, sphere-equivalent diameter, and sphere-equivalent area. These values were analyzed to compare the visibility of the leakage objectively.</p><p><strong>Results: </strong>At a constant flow rate, the intravascular pressure required for the model to leak was lower for the CO<sub>2</sub> than that for the iodine contrast medium. The CO<sub>2</sub> contrast medium leakage volume, equivalent circle diameter, and equivalent circle area were greater than those of the iodine one. These values indicate higher CO<sub>2</sub> visibility during fluoroscopy.</p><p><strong>Conclusions: </strong>In the bleeding model, a CO<sub>2</sub> contrast medium may be more prone to leakage than the iodine one in large and small wounds. Regarding visibility, a CO<sub>2</sub> contrast medium may be more likely to detect leakage than an iodine one.</p>","PeriodicalId":52351,"journal":{"name":"CVIR Endovascular","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11087413/pdf/","citationCount":"0","resultStr":"{\"title\":\"In vitro comparison of the leakage of carbon dioxide and iodine contrast media in a bleeding model.\",\"authors\":\"Ryoichi Kitamura, Kazuhiro Yoshida, Takaaki Maruhashi, Satoshi Tamura, Yutaro Kurihara, Koyo Suzuki, Yasushi Asari\",\"doi\":\"10.1186/s42155-024-00457-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We aimed to compare the hydrodynamic values of carbon dioxide (CO<sub>2</sub>) and iodine contrast media for bleeding detection using an in vitro model.</p><p><strong>Materials and methods: </strong>We created a bleeding model with large and small wounds in simulated blood vessels. We connected a syringe to the bleeding model and the blood pressure transducer, filling the circuit with CO<sub>2</sub> and iodine contrast media. The syringe's piston was pressed, and the flow rate and intravascular pressure of the CO<sub>2</sub> and iodine contrast media leaking from the bleeding model were measured. We compared each leaked contrast medium's volume, sphere-equivalent diameter, and sphere-equivalent area. These values were analyzed to compare the visibility of the leakage objectively.</p><p><strong>Results: </strong>At a constant flow rate, the intravascular pressure required for the model to leak was lower for the CO<sub>2</sub> than that for the iodine contrast medium. The CO<sub>2</sub> contrast medium leakage volume, equivalent circle diameter, and equivalent circle area were greater than those of the iodine one. These values indicate higher CO<sub>2</sub> visibility during fluoroscopy.</p><p><strong>Conclusions: </strong>In the bleeding model, a CO<sub>2</sub> contrast medium may be more prone to leakage than the iodine one in large and small wounds. Regarding visibility, a CO<sub>2</sub> contrast medium may be more likely to detect leakage than an iodine one.</p>\",\"PeriodicalId\":52351,\"journal\":{\"name\":\"CVIR Endovascular\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11087413/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CVIR Endovascular\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s42155-024-00457-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CVIR Endovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42155-024-00457-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:我们旨在利用体外模型比较二氧化碳(CO2)和碘造影剂在出血检测中的流体力学值:我们创建了一个出血模型,在模拟血管上有大伤口和小伤口。我们将注射器连接到出血模型和血压传感器,在回路中注入二氧化碳和碘造影剂。按下注射器的活塞,测量从出血模型中泄漏的二氧化碳和碘造影剂的流速和血管内压力。我们比较了每种泄漏造影剂的体积、球当量直径和球当量面积。我们对这些数值进行了分析,以客观地比较泄漏的可见度:结果:在恒定流速下,二氧化碳造影剂模型泄漏所需的血管内压力低于碘造影剂。二氧化碳造影剂的泄漏量、等效圆直径和等效圆面积均大于碘造影剂。这些数值表明二氧化碳在透视过程中的能见度更高:结论:在出血模型中,二氧化碳造影剂在大伤口和小伤口中可能比碘造影剂更容易渗漏。在能见度方面,二氧化碳造影剂可能比碘造影剂更容易发现渗漏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro comparison of the leakage of carbon dioxide and iodine contrast media in a bleeding model.

Background: We aimed to compare the hydrodynamic values of carbon dioxide (CO2) and iodine contrast media for bleeding detection using an in vitro model.

Materials and methods: We created a bleeding model with large and small wounds in simulated blood vessels. We connected a syringe to the bleeding model and the blood pressure transducer, filling the circuit with CO2 and iodine contrast media. The syringe's piston was pressed, and the flow rate and intravascular pressure of the CO2 and iodine contrast media leaking from the bleeding model were measured. We compared each leaked contrast medium's volume, sphere-equivalent diameter, and sphere-equivalent area. These values were analyzed to compare the visibility of the leakage objectively.

Results: At a constant flow rate, the intravascular pressure required for the model to leak was lower for the CO2 than that for the iodine contrast medium. The CO2 contrast medium leakage volume, equivalent circle diameter, and equivalent circle area were greater than those of the iodine one. These values indicate higher CO2 visibility during fluoroscopy.

Conclusions: In the bleeding model, a CO2 contrast medium may be more prone to leakage than the iodine one in large and small wounds. Regarding visibility, a CO2 contrast medium may be more likely to detect leakage than an iodine one.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CVIR Endovascular
CVIR Endovascular Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.30
自引率
0.00%
发文量
59
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信