Elissa R Engel, Tanya Perry, Mary Block, Joseph S Palumbo, Angela Lorts, Lori Luchtman-Jones
{"title":"小儿心室辅助装置和体外膜氧合中的比伐卢定监测:2018-2022年单中心回顾性队列数据分析。","authors":"Elissa R Engel, Tanya Perry, Mary Block, Joseph S Palumbo, Angela Lorts, Lori Luchtman-Jones","doi":"10.1097/PCC.0000000000003527","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The activated partial thromboplastin time (aPTT) is the most frequently used monitoring assay for bivalirudin in children and young adults on mechanical circulatory support including ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO). However, intrinsic variability of the aPTT complicates management and risks bleeding or thrombotic complications. We evaluated the utility and reliability of a bivalirudin-calibrated dilute thrombin time (Bival dTT) assay for bivalirudin monitoring in this population.</p><p><strong>Design: </strong>Retrospective analysis of clinical data (including aPTT, dilute thrombin time [dTT]) and results of residual plasma samples from VAD patients were assessed in two drug-calibrated experimental assays. One assay (Bival dTT) was validated for clinical use in VAD patients, and subsequently used by clinicians in ECMO patients. Pearson correlation and simple linear regression were used to determine R2 correlation coefficients between the different laboratory parameters using Statistical Package for Social Sciences (Armonk, NY).</p><p><strong>Setting: </strong>ICUs at Cincinnati Children's Hospital Medical Center.</p><p><strong>Subjects: </strong>Children on VAD or ECMO support anticoagulated with bivalirudin.</p><p><strong>Interventions: </strong>None.</p><p><strong>Measurements and main results: </strong>One hundred fifteen plasma samples from 11 VAD patients were analyzed. Both drug-calibrated experimental assays (anti-IIa and Bival dTT) showed excellent correlation with each other ( R2 = 0.94) and with the dTT ( R2 = 0.87), but poor correlation with aPTT ( R2 = 0.1). Bival dTT was selected for validation in VAD patients. Subsequently, clinically ordered results (105) from 11 ECMO patients demonstrated excellent correlation between the Bival dTT and the standard dTT ( R2 = 0.86) but very poor correlation with aPTT ( R2 = 0.004).</p><p><strong>Conclusions: </strong>APTT is unreliable and correlates poorly with bivalirudin's anticoagulant effect in ECMO and VAD patients. A drug-calibrated Bival dTT offers superior reliability and opportunity to standardize results across institutions. Additional studies are needed to determine an appropriate therapeutic range and correlation with clinical outcomes.</p>","PeriodicalId":19760,"journal":{"name":"Pediatric Critical Care Medicine","volume":null,"pages":null},"PeriodicalIF":4.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bivalirudin Monitoring in Pediatric Ventricular Assist Device and Extracorporeal Membrane Oxygenation: Analysis of Single-Center Retrospective Cohort Data 2018-2022.\",\"authors\":\"Elissa R Engel, Tanya Perry, Mary Block, Joseph S Palumbo, Angela Lorts, Lori Luchtman-Jones\",\"doi\":\"10.1097/PCC.0000000000003527\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The activated partial thromboplastin time (aPTT) is the most frequently used monitoring assay for bivalirudin in children and young adults on mechanical circulatory support including ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO). However, intrinsic variability of the aPTT complicates management and risks bleeding or thrombotic complications. We evaluated the utility and reliability of a bivalirudin-calibrated dilute thrombin time (Bival dTT) assay for bivalirudin monitoring in this population.</p><p><strong>Design: </strong>Retrospective analysis of clinical data (including aPTT, dilute thrombin time [dTT]) and results of residual plasma samples from VAD patients were assessed in two drug-calibrated experimental assays. One assay (Bival dTT) was validated for clinical use in VAD patients, and subsequently used by clinicians in ECMO patients. Pearson correlation and simple linear regression were used to determine R2 correlation coefficients between the different laboratory parameters using Statistical Package for Social Sciences (Armonk, NY).</p><p><strong>Setting: </strong>ICUs at Cincinnati Children's Hospital Medical Center.</p><p><strong>Subjects: </strong>Children on VAD or ECMO support anticoagulated with bivalirudin.</p><p><strong>Interventions: </strong>None.</p><p><strong>Measurements and main results: </strong>One hundred fifteen plasma samples from 11 VAD patients were analyzed. Both drug-calibrated experimental assays (anti-IIa and Bival dTT) showed excellent correlation with each other ( R2 = 0.94) and with the dTT ( R2 = 0.87), but poor correlation with aPTT ( R2 = 0.1). Bival dTT was selected for validation in VAD patients. Subsequently, clinically ordered results (105) from 11 ECMO patients demonstrated excellent correlation between the Bival dTT and the standard dTT ( R2 = 0.86) but very poor correlation with aPTT ( R2 = 0.004).</p><p><strong>Conclusions: </strong>APTT is unreliable and correlates poorly with bivalirudin's anticoagulant effect in ECMO and VAD patients. A drug-calibrated Bival dTT offers superior reliability and opportunity to standardize results across institutions. Additional studies are needed to determine an appropriate therapeutic range and correlation with clinical outcomes.</p>\",\"PeriodicalId\":19760,\"journal\":{\"name\":\"Pediatric Critical Care Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Critical Care Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PCC.0000000000003527\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Critical Care Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PCC.0000000000003527","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
Bivalirudin Monitoring in Pediatric Ventricular Assist Device and Extracorporeal Membrane Oxygenation: Analysis of Single-Center Retrospective Cohort Data 2018-2022.
Objectives: The activated partial thromboplastin time (aPTT) is the most frequently used monitoring assay for bivalirudin in children and young adults on mechanical circulatory support including ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO). However, intrinsic variability of the aPTT complicates management and risks bleeding or thrombotic complications. We evaluated the utility and reliability of a bivalirudin-calibrated dilute thrombin time (Bival dTT) assay for bivalirudin monitoring in this population.
Design: Retrospective analysis of clinical data (including aPTT, dilute thrombin time [dTT]) and results of residual plasma samples from VAD patients were assessed in two drug-calibrated experimental assays. One assay (Bival dTT) was validated for clinical use in VAD patients, and subsequently used by clinicians in ECMO patients. Pearson correlation and simple linear regression were used to determine R2 correlation coefficients between the different laboratory parameters using Statistical Package for Social Sciences (Armonk, NY).
Setting: ICUs at Cincinnati Children's Hospital Medical Center.
Subjects: Children on VAD or ECMO support anticoagulated with bivalirudin.
Interventions: None.
Measurements and main results: One hundred fifteen plasma samples from 11 VAD patients were analyzed. Both drug-calibrated experimental assays (anti-IIa and Bival dTT) showed excellent correlation with each other ( R2 = 0.94) and with the dTT ( R2 = 0.87), but poor correlation with aPTT ( R2 = 0.1). Bival dTT was selected for validation in VAD patients. Subsequently, clinically ordered results (105) from 11 ECMO patients demonstrated excellent correlation between the Bival dTT and the standard dTT ( R2 = 0.86) but very poor correlation with aPTT ( R2 = 0.004).
Conclusions: APTT is unreliable and correlates poorly with bivalirudin's anticoagulant effect in ECMO and VAD patients. A drug-calibrated Bival dTT offers superior reliability and opportunity to standardize results across institutions. Additional studies are needed to determine an appropriate therapeutic range and correlation with clinical outcomes.
期刊介绍:
Pediatric Critical Care Medicine is written for the entire critical care team: pediatricians, neonatologists, respiratory therapists, nurses, and others who deal with pediatric patients who are critically ill or injured. International in scope, with editorial board members and contributors from around the world, the Journal includes a full range of scientific content, including clinical articles, scientific investigations, solicited reviews, and abstracts from pediatric critical care meetings. Additionally, the Journal includes abstracts of selected articles published in Chinese, French, Italian, Japanese, Portuguese, and Spanish translations - making news of advances in the field available to pediatric and neonatal intensive care practitioners worldwide.