Syed Muzyan Shahzad, Asim Shahzad, Hammad Tariq Janjuhah, George Kontakiotis, Meryem Fanidi, Muhammad Ishfaque, Sajjad Ahmad Shah, Panayota Makri
{"title":"巴基斯坦白沙瓦东南部湖底含水层地下水潜力评估及其水文地质模型:对环境地质学和岩土工程学的影响","authors":"Syed Muzyan Shahzad, Asim Shahzad, Hammad Tariq Janjuhah, George Kontakiotis, Meryem Fanidi, Muhammad Ishfaque, Sajjad Ahmad Shah, Panayota Makri","doi":"10.1186/s40703-024-00213-5","DOIUrl":null,"url":null,"abstract":"<p>The Peshawar Basin is a part of the lower Himalayas that contains an enormous amount of groundwater storage. The evaluation of groundwater potential in the southern Peshawar district was done using well logging, lithostratigraphic properties, and combined hydrogeological and geophysical techniques. A total of 13 Vertical Electrical Sounding (VES) profiles were utilised to assess potential groundwater zones for surface resistivity studies. The aquifer system was delineated by comparing the data from five boreholes with the VES findings. An exploration of super-saturated groundwater potential was conducted, utilising parameters such as transmissivity (T), hydraulic conductivity (K), storativity, and the Dar Zarrouk analysis. The Dar Zarrouk analysis yielded average values of transverse resistance (TR), longitudinal conductance (S), and anisotropy (λ), which were determined to be 8069.12, 0.51, and 0.561, respectively. Similarly, average values of transmissivity (T), hydraulic conductivity (K), and storativity were obtained, resulting in 28.67, 0.24, and 0.000177, respectively. The saturated confined layer, characterized by highly saturated zones, was identified to begin at a depth of approximately 119 m and extend down to the lower boundary of the aquifer. The examined aquifer is composed of clay, sand, gravel, boulders, and loose layers of lacustrine mud that are interlayered to form an unconsolidated groundwater aquifer system. The aquifers in the region are highly developed and consisted of unconfined, semi-confined, and confined aquifer systems. As a result, it is possible to use the aquifer for groundwater development in the study area because of its low -to-medium discharge.</p>","PeriodicalId":44851,"journal":{"name":"International Journal of Geo-Engineering","volume":"44 1","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Appraisal of lacustrine aquifer’s groundwater potentiality and its hydrogeological modelling in southeastern Peshawar, Pakistan: implications for environmental geology, and geotechnical engineering\",\"authors\":\"Syed Muzyan Shahzad, Asim Shahzad, Hammad Tariq Janjuhah, George Kontakiotis, Meryem Fanidi, Muhammad Ishfaque, Sajjad Ahmad Shah, Panayota Makri\",\"doi\":\"10.1186/s40703-024-00213-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The Peshawar Basin is a part of the lower Himalayas that contains an enormous amount of groundwater storage. The evaluation of groundwater potential in the southern Peshawar district was done using well logging, lithostratigraphic properties, and combined hydrogeological and geophysical techniques. A total of 13 Vertical Electrical Sounding (VES) profiles were utilised to assess potential groundwater zones for surface resistivity studies. The aquifer system was delineated by comparing the data from five boreholes with the VES findings. An exploration of super-saturated groundwater potential was conducted, utilising parameters such as transmissivity (T), hydraulic conductivity (K), storativity, and the Dar Zarrouk analysis. The Dar Zarrouk analysis yielded average values of transverse resistance (TR), longitudinal conductance (S), and anisotropy (λ), which were determined to be 8069.12, 0.51, and 0.561, respectively. Similarly, average values of transmissivity (T), hydraulic conductivity (K), and storativity were obtained, resulting in 28.67, 0.24, and 0.000177, respectively. The saturated confined layer, characterized by highly saturated zones, was identified to begin at a depth of approximately 119 m and extend down to the lower boundary of the aquifer. The examined aquifer is composed of clay, sand, gravel, boulders, and loose layers of lacustrine mud that are interlayered to form an unconsolidated groundwater aquifer system. The aquifers in the region are highly developed and consisted of unconfined, semi-confined, and confined aquifer systems. As a result, it is possible to use the aquifer for groundwater development in the study area because of its low -to-medium discharge.</p>\",\"PeriodicalId\":44851,\"journal\":{\"name\":\"International Journal of Geo-Engineering\",\"volume\":\"44 1\",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Geo-Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s40703-024-00213-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Geo-Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40703-024-00213-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
Appraisal of lacustrine aquifer’s groundwater potentiality and its hydrogeological modelling in southeastern Peshawar, Pakistan: implications for environmental geology, and geotechnical engineering
The Peshawar Basin is a part of the lower Himalayas that contains an enormous amount of groundwater storage. The evaluation of groundwater potential in the southern Peshawar district was done using well logging, lithostratigraphic properties, and combined hydrogeological and geophysical techniques. A total of 13 Vertical Electrical Sounding (VES) profiles were utilised to assess potential groundwater zones for surface resistivity studies. The aquifer system was delineated by comparing the data from five boreholes with the VES findings. An exploration of super-saturated groundwater potential was conducted, utilising parameters such as transmissivity (T), hydraulic conductivity (K), storativity, and the Dar Zarrouk analysis. The Dar Zarrouk analysis yielded average values of transverse resistance (TR), longitudinal conductance (S), and anisotropy (λ), which were determined to be 8069.12, 0.51, and 0.561, respectively. Similarly, average values of transmissivity (T), hydraulic conductivity (K), and storativity were obtained, resulting in 28.67, 0.24, and 0.000177, respectively. The saturated confined layer, characterized by highly saturated zones, was identified to begin at a depth of approximately 119 m and extend down to the lower boundary of the aquifer. The examined aquifer is composed of clay, sand, gravel, boulders, and loose layers of lacustrine mud that are interlayered to form an unconsolidated groundwater aquifer system. The aquifers in the region are highly developed and consisted of unconfined, semi-confined, and confined aquifer systems. As a result, it is possible to use the aquifer for groundwater development in the study area because of its low -to-medium discharge.