血浆肾素和醛固酮测定现状透视:来自中国 526 家临床实验室的研究结果

IF 3.8 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Weiyan Zhou, Yuhang Deng, Wenjun Ma, Haijian Zhao, Kaijun Wang, Qian Zhang, Wei Gan, Wenxiang Chen, Jun Cai, Chuanbao Zhang
{"title":"血浆肾素和醛固酮测定现状透视:来自中国 526 家临床实验室的研究结果","authors":"Weiyan Zhou, Yuhang Deng, Wenjun Ma, Haijian Zhao, Kaijun Wang, Qian Zhang, Wei Gan, Wenxiang Chen, Jun Cai, Chuanbao Zhang","doi":"10.1515/cclm-2024-0373","DOIUrl":null,"url":null,"abstract":"Objectives Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients. Methods Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems. The inter- and intra-laboratory %CV were calculated and compared. To determine the source of the substantial inter-laboratory %CV, laboratories were categorized according to the measurement systems they are using, and both the inter- and intra-measurement-system %CV were calculated and compared. Results Regarding renin, the majority of laboratories use four primary commercial immunoassays. However, for aldosterone, in addition to commercial immunoassays, laboratory-developed liquid chromatography-tandem mass spectrometry (LC-MS) methods are also used by laboratories. The median values of intra-laboratory %CVs, intra-measurement-system %CVs, inter-laboratory %CVs, and inter-measurement systems %CVs varied between 1.6 and 2.6 %, 4.6 and 14.9 %, 8.3 and 25.7 %, and 10.0 and 34.4 % for renin, respectively. For aldosterone, these values ranged from 1.4 to 2.2 %, 2.5–14.7 %, 9.9–31.0 %, and 10.0–35.5 %, respectively. Conclusions The precision within laboratories and measurement systems for plasma renin and aldosterone measurements is satisfactory. However, the comparability between laboratories using different measurement systems remains lacking, indicating the long way to achieve standardization and harmonization for these two analytes.","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Insight into the status of plasma renin and aldosterone measurement: findings from 526 clinical laboratories in China\",\"authors\":\"Weiyan Zhou, Yuhang Deng, Wenjun Ma, Haijian Zhao, Kaijun Wang, Qian Zhang, Wei Gan, Wenxiang Chen, Jun Cai, Chuanbao Zhang\",\"doi\":\"10.1515/cclm-2024-0373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients. Methods Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems. The inter- and intra-laboratory %CV were calculated and compared. To determine the source of the substantial inter-laboratory %CV, laboratories were categorized according to the measurement systems they are using, and both the inter- and intra-measurement-system %CV were calculated and compared. Results Regarding renin, the majority of laboratories use four primary commercial immunoassays. However, for aldosterone, in addition to commercial immunoassays, laboratory-developed liquid chromatography-tandem mass spectrometry (LC-MS) methods are also used by laboratories. The median values of intra-laboratory %CVs, intra-measurement-system %CVs, inter-laboratory %CVs, and inter-measurement systems %CVs varied between 1.6 and 2.6 %, 4.6 and 14.9 %, 8.3 and 25.7 %, and 10.0 and 34.4 % for renin, respectively. For aldosterone, these values ranged from 1.4 to 2.2 %, 2.5–14.7 %, 9.9–31.0 %, and 10.0–35.5 %, respectively. Conclusions The precision within laboratories and measurement systems for plasma renin and aldosterone measurements is satisfactory. However, the comparability between laboratories using different measurement systems remains lacking, indicating the long way to achieve standardization and harmonization for these two analytes.\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2024-0373\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-0373","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的 准确测定肾素和醛固酮水平在原发性醛固酮增多症筛查中发挥着重要作用,而原发性醛固酮增多症筛查对高血压的管理和分类具有重要意义。本研究旨在调查中国血浆肾素和醛固酮的测定现状,通过分析全国 526 家临床实验室对 2,000 多名患者的三份新鲜血浆样本的测定结果来实现这一目的。方法 526 家实验室采用不同的测量系统对三份血浆样本中的肾素和醛固酮进行了四次测量。计算并比较了实验室间和实验室内的%CV。为了确定实验室间百分比变异率高的原因,根据实验室使用的测量系统对其进行了分类,并计算和比较了测量系统间和测量系统内的百分比变异率。结果 关于肾素,大多数实验室使用四种主要的商业免疫测定法。然而,对于醛固酮,除了商用免疫测定法外,实验室还使用了实验室开发的液相色谱-串联质谱(LC-MS)方法。肾素的实验室内百分比变异系数、测量系统内百分比变异系数、实验室间百分比变异系数和测量系统间百分比变异系数的中值分别为 1.6% 至 2.6%、4.6% 至 14.9%、8.3% 至 25.7%、10.0% 至 34.4%。醛固酮的误差范围分别为 1.4%至 2.2%、2.5%至 14.7%、9.9%至 31.0%,以及 10.0%至 35.5%。结论 血浆肾素和醛固酮测量在实验室和测量系统内的精确度令人满意。但是,使用不同测量系统的实验室之间仍然缺乏可比性,这表明要实现这两种分析物的标准化和统一化还有很长的路要走。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Insight into the status of plasma renin and aldosterone measurement: findings from 526 clinical laboratories in China
Objectives Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients. Methods Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems. The inter- and intra-laboratory %CV were calculated and compared. To determine the source of the substantial inter-laboratory %CV, laboratories were categorized according to the measurement systems they are using, and both the inter- and intra-measurement-system %CV were calculated and compared. Results Regarding renin, the majority of laboratories use four primary commercial immunoassays. However, for aldosterone, in addition to commercial immunoassays, laboratory-developed liquid chromatography-tandem mass spectrometry (LC-MS) methods are also used by laboratories. The median values of intra-laboratory %CVs, intra-measurement-system %CVs, inter-laboratory %CVs, and inter-measurement systems %CVs varied between 1.6 and 2.6 %, 4.6 and 14.9 %, 8.3 and 25.7 %, and 10.0 and 34.4 % for renin, respectively. For aldosterone, these values ranged from 1.4 to 2.2 %, 2.5–14.7 %, 9.9–31.0 %, and 10.0–35.5 %, respectively. Conclusions The precision within laboratories and measurement systems for plasma renin and aldosterone measurements is satisfactory. However, the comparability between laboratories using different measurement systems remains lacking, indicating the long way to achieve standardization and harmonization for these two analytes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信