Martina Beese , Tomass Andersons , Mathias Sawall , Cyril Ruckebusch , Adrián Gómez-Sánchez , Robert Francke , Adrian Prudlik , Robert Franke , Klaus Neymeyr
{"title":"论块状不完整数据集 MCR 问题的因子模糊性","authors":"Martina Beese , Tomass Andersons , Mathias Sawall , Cyril Ruckebusch , Adrián Gómez-Sánchez , Robert Francke , Adrian Prudlik , Robert Franke , Klaus Neymeyr","doi":"10.1016/j.chemolab.2024.105134","DOIUrl":null,"url":null,"abstract":"<div><p>Multivariate curve resolution (MCR) methods are sometimes faced with missing or erroneous data, e.g., due to sensor saturation. In some cases, an estimation of the missing data is possible, but often MCR works with the largest submatrix without missing entries. This ignores all rows and columns of the data matrix that contain missing values. A successful approach to deal with incomplete data multisets has been proposed by Alier and Tauler (2013), but it does not include a factor ambiguity analysis. Here, the missing data problem is addressed in combination with a factor ambiguity analysis. An approach is presented that minimizes the factor ambiguity by extracting a maximum of spectral information even from incomplete rows and columns of the spectral data matrix. The method requires a high signal-to-noise ratio. Applications are presented for UV/Vis and HSI data.</p></div>","PeriodicalId":9774,"journal":{"name":"Chemometrics and Intelligent Laboratory Systems","volume":"249 ","pages":"Article 105134"},"PeriodicalIF":3.7000,"publicationDate":"2024-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0169743924000741/pdfft?md5=bb7d17fc695f88d0275f3839df0eb621&pid=1-s2.0-S0169743924000741-main.pdf","citationCount":"0","resultStr":"{\"title\":\"On the factor ambiguity of MCR problems for blockwise incomplete data sets\",\"authors\":\"Martina Beese , Tomass Andersons , Mathias Sawall , Cyril Ruckebusch , Adrián Gómez-Sánchez , Robert Francke , Adrian Prudlik , Robert Franke , Klaus Neymeyr\",\"doi\":\"10.1016/j.chemolab.2024.105134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Multivariate curve resolution (MCR) methods are sometimes faced with missing or erroneous data, e.g., due to sensor saturation. In some cases, an estimation of the missing data is possible, but often MCR works with the largest submatrix without missing entries. This ignores all rows and columns of the data matrix that contain missing values. A successful approach to deal with incomplete data multisets has been proposed by Alier and Tauler (2013), but it does not include a factor ambiguity analysis. Here, the missing data problem is addressed in combination with a factor ambiguity analysis. An approach is presented that minimizes the factor ambiguity by extracting a maximum of spectral information even from incomplete rows and columns of the spectral data matrix. The method requires a high signal-to-noise ratio. Applications are presented for UV/Vis and HSI data.</p></div>\",\"PeriodicalId\":9774,\"journal\":{\"name\":\"Chemometrics and Intelligent Laboratory Systems\",\"volume\":\"249 \",\"pages\":\"Article 105134\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2024-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0169743924000741/pdfft?md5=bb7d17fc695f88d0275f3839df0eb621&pid=1-s2.0-S0169743924000741-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemometrics and Intelligent Laboratory Systems\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0169743924000741\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"AUTOMATION & CONTROL SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemometrics and Intelligent Laboratory Systems","FirstCategoryId":"94","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0169743924000741","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
On the factor ambiguity of MCR problems for blockwise incomplete data sets
Multivariate curve resolution (MCR) methods are sometimes faced with missing or erroneous data, e.g., due to sensor saturation. In some cases, an estimation of the missing data is possible, but often MCR works with the largest submatrix without missing entries. This ignores all rows and columns of the data matrix that contain missing values. A successful approach to deal with incomplete data multisets has been proposed by Alier and Tauler (2013), but it does not include a factor ambiguity analysis. Here, the missing data problem is addressed in combination with a factor ambiguity analysis. An approach is presented that minimizes the factor ambiguity by extracting a maximum of spectral information even from incomplete rows and columns of the spectral data matrix. The method requires a high signal-to-noise ratio. Applications are presented for UV/Vis and HSI data.
期刊介绍:
Chemometrics and Intelligent Laboratory Systems publishes original research papers, short communications, reviews, tutorials and Original Software Publications reporting on development of novel statistical, mathematical, or computer techniques in Chemistry and related disciplines.
Chemometrics is the chemical discipline that uses mathematical and statistical methods to design or select optimal procedures and experiments, and to provide maximum chemical information by analysing chemical data.
The journal deals with the following topics:
1) Development of new statistical, mathematical and chemometrical methods for Chemistry and related fields (Environmental Chemistry, Biochemistry, Toxicology, System Biology, -Omics, etc.)
2) Novel applications of chemometrics to all branches of Chemistry and related fields (typical domains of interest are: process data analysis, experimental design, data mining, signal processing, supervised modelling, decision making, robust statistics, mixture analysis, multivariate calibration etc.) Routine applications of established chemometrical techniques will not be considered.
3) Development of new software that provides novel tools or truly advances the use of chemometrical methods.
4) Well characterized data sets to test performance for the new methods and software.
The journal complies with International Committee of Medical Journal Editors'' Uniform requirements for manuscripts.