{"title":"植入心脏电子设备的患者通过心房抗心动过速起搏成功终止心房颤动的特征","authors":"Yoshiyasu Aizawa, Satoru Komura, Emiko Kawakami, Shonosuke Watanabe, Kazuki Tanaka, Hiromu Kadowaki, Atsushi Takagi","doi":"10.1007/s00380-024-02409-2","DOIUrl":null,"url":null,"abstract":"<p>Asymptomatic paroxysmal atrial fibrillation (AF) is often found in patients implanted with cardiac implantable electronic devices (CIEDs). Second-generation atrial antitachycardia pacing (A-ATP) is effective in managing AF in patients implanted with CIEDs. The purpose of this study was to evaluate the efficacy and safety of A-ATP in patients implanted with CIEDs. This was a single-center retrospective study involving 91 patients (male 46 patients, mean age 74 ± 9 years) implanted with Reactive A-ATP equipped devices (84 patients with pacemakers, 6 with ICDs, and 1 with a CRT-D). The AF burden, rate of AF termination, and details of the activation of the A-ATP were analyzed in each patient. During a mean follow-up period of 21 ± 13 months, A-ATP was activated in 45 of 91 patients (49.5%). No patients had adverse events. Although the efficacy of the A-ATP varied among the patients, the median rate of AF termination was 44%. In comparison to the A-ATP start time, “0 min” had a higher AF termination rate by the A-ATP (39.4% vs. 24.4%, <i>P</i> = 0.011). The rate of termination by the A-ATP was high for AF with a long cycle length and a relatively regular rhythm. A-ATP successfully terminated AF episodes in some patients implanted with CIEDs. The optimal settings of the A-ATP will be determined in future studies.</p>","PeriodicalId":12940,"journal":{"name":"Heart and Vessels","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characteristics of successful termination of atrial fibrillation by atrial antitachycardia pacing in patients with cardiac implantable electronic devices\",\"authors\":\"Yoshiyasu Aizawa, Satoru Komura, Emiko Kawakami, Shonosuke Watanabe, Kazuki Tanaka, Hiromu Kadowaki, Atsushi Takagi\",\"doi\":\"10.1007/s00380-024-02409-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Asymptomatic paroxysmal atrial fibrillation (AF) is often found in patients implanted with cardiac implantable electronic devices (CIEDs). Second-generation atrial antitachycardia pacing (A-ATP) is effective in managing AF in patients implanted with CIEDs. The purpose of this study was to evaluate the efficacy and safety of A-ATP in patients implanted with CIEDs. This was a single-center retrospective study involving 91 patients (male 46 patients, mean age 74 ± 9 years) implanted with Reactive A-ATP equipped devices (84 patients with pacemakers, 6 with ICDs, and 1 with a CRT-D). The AF burden, rate of AF termination, and details of the activation of the A-ATP were analyzed in each patient. During a mean follow-up period of 21 ± 13 months, A-ATP was activated in 45 of 91 patients (49.5%). No patients had adverse events. Although the efficacy of the A-ATP varied among the patients, the median rate of AF termination was 44%. In comparison to the A-ATP start time, “0 min” had a higher AF termination rate by the A-ATP (39.4% vs. 24.4%, <i>P</i> = 0.011). The rate of termination by the A-ATP was high for AF with a long cycle length and a relatively regular rhythm. A-ATP successfully terminated AF episodes in some patients implanted with CIEDs. The optimal settings of the A-ATP will be determined in future studies.</p>\",\"PeriodicalId\":12940,\"journal\":{\"name\":\"Heart and Vessels\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-04-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart and Vessels\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00380-024-02409-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart and Vessels","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00380-024-02409-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Characteristics of successful termination of atrial fibrillation by atrial antitachycardia pacing in patients with cardiac implantable electronic devices
Asymptomatic paroxysmal atrial fibrillation (AF) is often found in patients implanted with cardiac implantable electronic devices (CIEDs). Second-generation atrial antitachycardia pacing (A-ATP) is effective in managing AF in patients implanted with CIEDs. The purpose of this study was to evaluate the efficacy and safety of A-ATP in patients implanted with CIEDs. This was a single-center retrospective study involving 91 patients (male 46 patients, mean age 74 ± 9 years) implanted with Reactive A-ATP equipped devices (84 patients with pacemakers, 6 with ICDs, and 1 with a CRT-D). The AF burden, rate of AF termination, and details of the activation of the A-ATP were analyzed in each patient. During a mean follow-up period of 21 ± 13 months, A-ATP was activated in 45 of 91 patients (49.5%). No patients had adverse events. Although the efficacy of the A-ATP varied among the patients, the median rate of AF termination was 44%. In comparison to the A-ATP start time, “0 min” had a higher AF termination rate by the A-ATP (39.4% vs. 24.4%, P = 0.011). The rate of termination by the A-ATP was high for AF with a long cycle length and a relatively regular rhythm. A-ATP successfully terminated AF episodes in some patients implanted with CIEDs. The optimal settings of the A-ATP will be determined in future studies.
期刊介绍:
Heart and Vessels is an English-language journal that provides a forum of original ideas, excellent methods, and fascinating techniques on cardiovascular disease fields. All papers submitted for publication are evaluated only with regard to scientific quality and relevance to the heart and vessels. Contributions from those engaged in practical medicine, as well as from those involved in basic research, are welcomed.