三种旋转式镍钛锉的循环疲劳和结构分析

Mahmoud Abdelaaty, Ahmed Hashem, Shady Hussien
{"title":"三种旋转式镍钛锉的循环疲劳和结构分析","authors":"Mahmoud Abdelaaty, Ahmed Hashem, Shady Hussien","doi":"10.21608/edj.2024.264175.2891","DOIUrl":null,"url":null,"abstract":"Nickel-titanium (NiTi) rotary shaping techniques were devised as a solution to the drawbacks associated with manual filing systems.The study was conducted to evaluate the cyclic fatigue resistance and martensitic/austenitic phase at body and room temperatures for HyFlex CM, Fanta (AH wire), Soco files. Twenty files of each system were used. Ten of them were used at room temperature and ten were used at body temperature. Dynamic cyclic fatigue testing was performed with a specific device, which allowed the instruments to rotate freely inside a Stainless-Steel artificial canal while providing an axial movement with amplitude of 3mm up and down movement. The time was calculated until instrument fracture occurred. A Sample with weight 10 to 15 grams of each instrument was evaluated using Differential Scanning Calorimetry (DSC).The DSC analyses were conducted over a temperature range from 0°C to 60°C . The results showed that HyFlex CM exhibited higher cyclic fatigue, followed by Fanta(AH wire), while soco showed the lowest values for both room and body temperatures. Temperature showed an effect (between body and room temperature) on cyclic fatigue resistance of some of CM wire type of instruments (Fanta and soco files).The differential scanning calorimetry confirmed the presence of the martensitic R-phase in Hyflex CM in both body and room temperatures which improved the cyclic fatigue resistance of this file, while presence of the martensitic phase only in room temperature for Fanta and Soco files not in body temperature which significantly decreases their cyclic fatigue resistance.","PeriodicalId":11504,"journal":{"name":"Egyptian dental journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cyclic fatigue and Structural Analysis of Three Rotary Nickel Titanium Files\",\"authors\":\"Mahmoud Abdelaaty, Ahmed Hashem, Shady Hussien\",\"doi\":\"10.21608/edj.2024.264175.2891\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nickel-titanium (NiTi) rotary shaping techniques were devised as a solution to the drawbacks associated with manual filing systems.The study was conducted to evaluate the cyclic fatigue resistance and martensitic/austenitic phase at body and room temperatures for HyFlex CM, Fanta (AH wire), Soco files. Twenty files of each system were used. Ten of them were used at room temperature and ten were used at body temperature. Dynamic cyclic fatigue testing was performed with a specific device, which allowed the instruments to rotate freely inside a Stainless-Steel artificial canal while providing an axial movement with amplitude of 3mm up and down movement. The time was calculated until instrument fracture occurred. A Sample with weight 10 to 15 grams of each instrument was evaluated using Differential Scanning Calorimetry (DSC).The DSC analyses were conducted over a temperature range from 0°C to 60°C . The results showed that HyFlex CM exhibited higher cyclic fatigue, followed by Fanta(AH wire), while soco showed the lowest values for both room and body temperatures. Temperature showed an effect (between body and room temperature) on cyclic fatigue resistance of some of CM wire type of instruments (Fanta and soco files).The differential scanning calorimetry confirmed the presence of the martensitic R-phase in Hyflex CM in both body and room temperatures which improved the cyclic fatigue resistance of this file, while presence of the martensitic phase only in room temperature for Fanta and Soco files not in body temperature which significantly decreases their cyclic fatigue resistance.\",\"PeriodicalId\":11504,\"journal\":{\"name\":\"Egyptian dental journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian dental journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/edj.2024.264175.2891\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/edj.2024.264175.2891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

该研究旨在评估 HyFlex CM、Fanta(AH 线)和 Soco 锉刀在体温和室温下的循环抗疲劳性和马氏体/奥氏体相。每个系统使用了 20 个锉刀。其中 10 个在室温下使用,10 个在体温下使用。动态循环疲劳测试是通过一个特定的装置进行的,该装置允许器械在不锈钢人工管道内自由旋转,同时提供上下移动幅度为 3 毫米的轴向移动。计算时间直至器械断裂。使用差示扫描量热法(DSC)对每种器械重量为 10 至 15 克的样品进行了评估。结果显示,HyFlex CM 的循环疲劳值较高,其次是 Fanta(AH 金属丝),而 soco 在室温和体温下的循环疲劳值最低。差示扫描量热仪证实,Hyflex CM 在体温和室温下都存在马氏体 R 相,这提高了这种锉刀的抗循环疲劳性,而 Fanta 和 Soco 锉刀仅在室温下存在马氏体相,在体温下不存在,这大大降低了它们的抗循环疲劳性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cyclic fatigue and Structural Analysis of Three Rotary Nickel Titanium Files
Nickel-titanium (NiTi) rotary shaping techniques were devised as a solution to the drawbacks associated with manual filing systems.The study was conducted to evaluate the cyclic fatigue resistance and martensitic/austenitic phase at body and room temperatures for HyFlex CM, Fanta (AH wire), Soco files. Twenty files of each system were used. Ten of them were used at room temperature and ten were used at body temperature. Dynamic cyclic fatigue testing was performed with a specific device, which allowed the instruments to rotate freely inside a Stainless-Steel artificial canal while providing an axial movement with amplitude of 3mm up and down movement. The time was calculated until instrument fracture occurred. A Sample with weight 10 to 15 grams of each instrument was evaluated using Differential Scanning Calorimetry (DSC).The DSC analyses were conducted over a temperature range from 0°C to 60°C . The results showed that HyFlex CM exhibited higher cyclic fatigue, followed by Fanta(AH wire), while soco showed the lowest values for both room and body temperatures. Temperature showed an effect (between body and room temperature) on cyclic fatigue resistance of some of CM wire type of instruments (Fanta and soco files).The differential scanning calorimetry confirmed the presence of the martensitic R-phase in Hyflex CM in both body and room temperatures which improved the cyclic fatigue resistance of this file, while presence of the martensitic phase only in room temperature for Fanta and Soco files not in body temperature which significantly decreases their cyclic fatigue resistance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信