带模块化双头的专用波束内 PET 系统,用于 HIMM 放射治疗成像

Jie Kong, Xibo Zhou, Changxin Wang, Jinda Chen, Genyuan Liang, Chengming Du, Q. She, Yi Qian, Junwei Yan
{"title":"带模块化双头的专用波束内 PET 系统,用于 HIMM 放射治疗成像","authors":"Jie Kong, Xibo Zhou, Changxin Wang, Jinda Chen, Genyuan Liang, Chengming Du, Q. She, Yi Qian, Junwei Yan","doi":"10.1088/1748-0221/19/04/p04021","DOIUrl":null,"url":null,"abstract":"\n This paper presents a heavy-ion in-beam PET, referred to as ibPET with a specifically custom designed data acquisition system, which was constructed and tested at the Heavy Ion Medical Machine (HIMM) beam-line, HICTC in Wuwei. The data acquisition system of ibPET has undergone several upgrades during the years, And its data processing capability now exceeds one million events per second per channel. To achieve optimal performance of the ibPET under existing conditions, we tested coincident events and noise equivalent count (NEC) under different time coincidence windows.The results show that the signal-to-noise ratio of the reconstructed image data reaches its peak when the time window is around 3 ns, indicating that the ibPET performance is optimal at this point. In order to determine the size of the time window, we measured the system's time resolution FWHM to be 1.63 ns, and ultimately chose a time window size of twice the time resolution FWHM, which is 3.25 ns. Meanwhile, we demonstrate the capability of our ibPET to monitor the dose range with various irradiation. The results demonstrate that the system exhibits the expected exponential decay in counting rate after irradiation, and accurately provides penetration depth positions at different energy levels.","PeriodicalId":507814,"journal":{"name":"Journal of Instrumentation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A dedicated in-beam PET system with a modular dual-head for radiotherapy imaging in HIMM\",\"authors\":\"Jie Kong, Xibo Zhou, Changxin Wang, Jinda Chen, Genyuan Liang, Chengming Du, Q. She, Yi Qian, Junwei Yan\",\"doi\":\"10.1088/1748-0221/19/04/p04021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n This paper presents a heavy-ion in-beam PET, referred to as ibPET with a specifically custom designed data acquisition system, which was constructed and tested at the Heavy Ion Medical Machine (HIMM) beam-line, HICTC in Wuwei. The data acquisition system of ibPET has undergone several upgrades during the years, And its data processing capability now exceeds one million events per second per channel. To achieve optimal performance of the ibPET under existing conditions, we tested coincident events and noise equivalent count (NEC) under different time coincidence windows.The results show that the signal-to-noise ratio of the reconstructed image data reaches its peak when the time window is around 3 ns, indicating that the ibPET performance is optimal at this point. In order to determine the size of the time window, we measured the system's time resolution FWHM to be 1.63 ns, and ultimately chose a time window size of twice the time resolution FWHM, which is 3.25 ns. Meanwhile, we demonstrate the capability of our ibPET to monitor the dose range with various irradiation. The results demonstrate that the system exhibits the expected exponential decay in counting rate after irradiation, and accurately provides penetration depth positions at different energy levels.\",\"PeriodicalId\":507814,\"journal\":{\"name\":\"Journal of Instrumentation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1748-0221/19/04/p04021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1748-0221/19/04/p04021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种重离子束内 PET(简称 ibPET),它配备了专门定制的数据采集系统,该系统在武威重离子医学中心的重离子医学机器(HIMM)束线上构建和测试。多年来,ibPET 的数据采集系统经历了多次升级,其数据处理能力现已超过每通道每秒一百万个事件。为了使ibPET在现有条件下达到最佳性能,我们测试了不同时间重合窗口下的重合事件和噪声等效计数(NEC)。结果表明,当时间窗口在3 ns左右时,重建图像数据的信噪比达到峰值,表明此时ibPET性能最佳。为了确定时间窗的大小,我们测量了系统的时间分辨率 FWHM 为 1.63 ns,最终选择了两倍于时间分辨率 FWHM 的时间窗大小,即 3.25 ns。同时,我们展示了我们的 ibPET 监测各种辐照剂量范围的能力。结果表明,该系统在辐照后呈现出预期的指数衰减计数率,并能准确提供不同能量水平下的穿透深度位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A dedicated in-beam PET system with a modular dual-head for radiotherapy imaging in HIMM
This paper presents a heavy-ion in-beam PET, referred to as ibPET with a specifically custom designed data acquisition system, which was constructed and tested at the Heavy Ion Medical Machine (HIMM) beam-line, HICTC in Wuwei. The data acquisition system of ibPET has undergone several upgrades during the years, And its data processing capability now exceeds one million events per second per channel. To achieve optimal performance of the ibPET under existing conditions, we tested coincident events and noise equivalent count (NEC) under different time coincidence windows.The results show that the signal-to-noise ratio of the reconstructed image data reaches its peak when the time window is around 3 ns, indicating that the ibPET performance is optimal at this point. In order to determine the size of the time window, we measured the system's time resolution FWHM to be 1.63 ns, and ultimately chose a time window size of twice the time resolution FWHM, which is 3.25 ns. Meanwhile, we demonstrate the capability of our ibPET to monitor the dose range with various irradiation. The results demonstrate that the system exhibits the expected exponential decay in counting rate after irradiation, and accurately provides penetration depth positions at different energy levels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信