F. Buthmann, Jan Hohlmann, Mareen Neuwald, Gerhard Schembecker
{"title":"通过重新配料优化色谱分离:离心分离色谱模型系统对分离效率的影响","authors":"F. Buthmann, Jan Hohlmann, Mareen Neuwald, Gerhard Schembecker","doi":"10.3390/separations11040111","DOIUrl":null,"url":null,"abstract":"This study investigates and optimizes chromatographic separation in a Centrifugal Partition Chromatograph. Therefore, a model system is separated in a single-disc rotor. The occurring loss of the stationary phase lowers the separation efficiency over time. We introduced a new mode of operation, called the redosing of the stationary phase, to counteract this hydrodynamic phenomenon. Experiments with redosing at an optimized operating point demonstrate almost constant separation performance over 12 h, reducing solvent consumption by 45% and increasing chromatographic resolution by 37%. The improvement in retention by 69% contributes to this enhancement. Accordingly, reference experiments without redosing were conducted as a benchmark, highlighting the automated mode’s benefits, as mentioned.","PeriodicalId":510456,"journal":{"name":"Separations","volume":"78 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimizing Chromatographic Separation with Redosing: Effects on Separation Efficiency of a Model System in Centrifugal Partition Chromatography\",\"authors\":\"F. Buthmann, Jan Hohlmann, Mareen Neuwald, Gerhard Schembecker\",\"doi\":\"10.3390/separations11040111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study investigates and optimizes chromatographic separation in a Centrifugal Partition Chromatograph. Therefore, a model system is separated in a single-disc rotor. The occurring loss of the stationary phase lowers the separation efficiency over time. We introduced a new mode of operation, called the redosing of the stationary phase, to counteract this hydrodynamic phenomenon. Experiments with redosing at an optimized operating point demonstrate almost constant separation performance over 12 h, reducing solvent consumption by 45% and increasing chromatographic resolution by 37%. The improvement in retention by 69% contributes to this enhancement. Accordingly, reference experiments without redosing were conducted as a benchmark, highlighting the automated mode’s benefits, as mentioned.\",\"PeriodicalId\":510456,\"journal\":{\"name\":\"Separations\",\"volume\":\"78 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Separations\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/separations11040111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Separations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/separations11040111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimizing Chromatographic Separation with Redosing: Effects on Separation Efficiency of a Model System in Centrifugal Partition Chromatography
This study investigates and optimizes chromatographic separation in a Centrifugal Partition Chromatograph. Therefore, a model system is separated in a single-disc rotor. The occurring loss of the stationary phase lowers the separation efficiency over time. We introduced a new mode of operation, called the redosing of the stationary phase, to counteract this hydrodynamic phenomenon. Experiments with redosing at an optimized operating point demonstrate almost constant separation performance over 12 h, reducing solvent consumption by 45% and increasing chromatographic resolution by 37%. The improvement in retention by 69% contributes to this enhancement. Accordingly, reference experiments without redosing were conducted as a benchmark, highlighting the automated mode’s benefits, as mentioned.