通过电凝和氢氧化铝絮凝体吸附氟化物对自来水进行除氟处理

Water Supply Pub Date : 2024-04-09 DOI:10.2166/ws.2024.079
Sirin Dhifallah, Anis Attour, Christophe Vial, Fehti Zagrouba, F. Audonnet
{"title":"通过电凝和氢氧化铝絮凝体吸附氟化物对自来水进行除氟处理","authors":"Sirin Dhifallah, Anis Attour, Christophe Vial, Fehti Zagrouba, F. Audonnet","doi":"10.2166/ws.2024.079","DOIUrl":null,"url":null,"abstract":"\n \n Overload of fluoride ions in water is observed in several regions of southern Tunisia, mainly the regions close to the mining basin of Gafsa: Metlaoui, Omlarayes and Redayef. This study concerns fluoride removal from Metlaoui's tap water by electrocoagulation (EC) using aluminum electrodes in a batch reactor. This water contains 3.5 mg·L−1 of fluoride, the highest concentration observed in these basins. The effect of the operating conditions of EC treatment on tap water defluoridation was analyzed, namely, current density, temperature and interelectrode distance. Hydroxide aluminum flocs, formed with different durations of EC, were used as sorbents in fluorinated deionized water ([F−] = 3.5 mg·L−1) and Metlaoui's tap water. Flocs formed after 30 min of EC, produced by dissolving (79 ± 1) mg·L−1 of aluminum and adjusted at pH = 6.5, allowed the adsorption of (98 ± 1)% of fluoride ions from deionized fluorinated water. Flocs adjusted at different pH, from 5 to 9, were used as sorbents in fluorinated deionized water and Metlaoui's tap water. Acidic and neutral flocs allowed the best yields of fluoride adsorption. Contrary to the literature, this work highlighted the absence of ion exchange of hydroxide anion by fluoride anion in water, highlighting a mechanism of physical adsorption on aluminum hydroxide flocs.","PeriodicalId":509977,"journal":{"name":"Water Supply","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Defluoridation of tap water by electrocoagulation and fluoride adsorption on aluminum hydroxide flocs\",\"authors\":\"Sirin Dhifallah, Anis Attour, Christophe Vial, Fehti Zagrouba, F. Audonnet\",\"doi\":\"10.2166/ws.2024.079\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n \\n Overload of fluoride ions in water is observed in several regions of southern Tunisia, mainly the regions close to the mining basin of Gafsa: Metlaoui, Omlarayes and Redayef. This study concerns fluoride removal from Metlaoui's tap water by electrocoagulation (EC) using aluminum electrodes in a batch reactor. This water contains 3.5 mg·L−1 of fluoride, the highest concentration observed in these basins. The effect of the operating conditions of EC treatment on tap water defluoridation was analyzed, namely, current density, temperature and interelectrode distance. Hydroxide aluminum flocs, formed with different durations of EC, were used as sorbents in fluorinated deionized water ([F−] = 3.5 mg·L−1) and Metlaoui's tap water. Flocs formed after 30 min of EC, produced by dissolving (79 ± 1) mg·L−1 of aluminum and adjusted at pH = 6.5, allowed the adsorption of (98 ± 1)% of fluoride ions from deionized fluorinated water. Flocs adjusted at different pH, from 5 to 9, were used as sorbents in fluorinated deionized water and Metlaoui's tap water. Acidic and neutral flocs allowed the best yields of fluoride adsorption. Contrary to the literature, this work highlighted the absence of ion exchange of hydroxide anion by fluoride anion in water, highlighting a mechanism of physical adsorption on aluminum hydroxide flocs.\",\"PeriodicalId\":509977,\"journal\":{\"name\":\"Water Supply\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Supply\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/ws.2024.079\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Supply","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/ws.2024.079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在突尼斯南部的几个地区,主要是靠近加夫萨矿业盆地的地区,发现水中氟离子超标:Metlaoui、Omlarayes 和 Redayef。本研究涉及在间歇式反应器中使用铝电极,通过电凝(EC)去除 Metlaoui 自来水中的氟化物。自来水中的氟含量为 3.5 mg-L-1,是在这些盆地中观察到的最高浓度。分析了电解处理的操作条件对自来水除氟的影响,即电流密度、温度和电极间距离。在含氟去离子水([F-] = 3.5 mg-L-1)和梅特劳伊自来水中使用了不同电解时间形成的氢氧化铝絮凝物作为吸附剂。通过溶解(79 ± 1)mg-L-1 的铝并在 pH = 6.5 的条件下调节,在电解质作用 30 分钟后形成的絮凝体可以吸附去离子水中(98 ± 1)%的氟离子。在含氟去离子水和 Metlaoui 自来水中使用不同 pH 值(5 至 9)的絮凝体作为吸附剂。酸性和中性絮凝物的氟吸附率最高。与文献报道相反,这项研究强调了氢氧阴离子与水中的氟阴离子不存在离子交换,突出了氢氧化铝絮凝体的物理吸附机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Defluoridation of tap water by electrocoagulation and fluoride adsorption on aluminum hydroxide flocs
Overload of fluoride ions in water is observed in several regions of southern Tunisia, mainly the regions close to the mining basin of Gafsa: Metlaoui, Omlarayes and Redayef. This study concerns fluoride removal from Metlaoui's tap water by electrocoagulation (EC) using aluminum electrodes in a batch reactor. This water contains 3.5 mg·L−1 of fluoride, the highest concentration observed in these basins. The effect of the operating conditions of EC treatment on tap water defluoridation was analyzed, namely, current density, temperature and interelectrode distance. Hydroxide aluminum flocs, formed with different durations of EC, were used as sorbents in fluorinated deionized water ([F−] = 3.5 mg·L−1) and Metlaoui's tap water. Flocs formed after 30 min of EC, produced by dissolving (79 ± 1) mg·L−1 of aluminum and adjusted at pH = 6.5, allowed the adsorption of (98 ± 1)% of fluoride ions from deionized fluorinated water. Flocs adjusted at different pH, from 5 to 9, were used as sorbents in fluorinated deionized water and Metlaoui's tap water. Acidic and neutral flocs allowed the best yields of fluoride adsorption. Contrary to the literature, this work highlighted the absence of ion exchange of hydroxide anion by fluoride anion in water, highlighting a mechanism of physical adsorption on aluminum hydroxide flocs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信