Rikuo Nishii, Masanori Goto, Yuki Takano, Kota Nakajima, Takateru Takamatsu, Masanori Tokuda, Hikari Tomita, Mai Yoshimoto, Satohiro Kawade, Yasuhiro Yamamoto, Yuji Naramoto, Kunimasa Teranishi, Nobuyuki Fukui, T. Sunohara, R. Fukumitsu, Junichi Takeda, Masaomi Koyanagi, C. Sakai, Nobuyuki Sakai, T. Ohta
{"title":"使用闭合尖端支架回取器预防后循环远端栓塞的新方法:示例病例","authors":"Rikuo Nishii, Masanori Goto, Yuki Takano, Kota Nakajima, Takateru Takamatsu, Masanori Tokuda, Hikari Tomita, Mai Yoshimoto, Satohiro Kawade, Yasuhiro Yamamoto, Yuji Naramoto, Kunimasa Teranishi, Nobuyuki Fukui, T. Sunohara, R. Fukumitsu, Junichi Takeda, Masaomi Koyanagi, C. Sakai, Nobuyuki Sakai, T. Ohta","doi":"10.3171/CASE24137","DOIUrl":null,"url":null,"abstract":"BACKGROUND In mechanical thrombectomy for tandem occlusions in vertebrobasilar stroke, distal emboli from the vertebral artery lesion should be prevented. However, no suitable embolic protection devices are currently available in the posterior circulation. Here, the authors describe the case of a vertebral artery lesion effectively treated with a closed-tip stent retriever as an embolic protection device in the posterior circulation. OBSERVATIONS A 65-year-old male underwent mechanical thrombectomy for basilar artery occlusion, with tandem occlusion of the proximal vertebral artery. After basilar artery recanalization via the nonoccluded vertebral artery, a subsequent mechanical thrombectomy was performed for the occluded proximal vertebral artery. To prevent distal embolization of the basilar artery, an EmboTrap III stent retriever was deployed as an embolic protection device within the basilar artery to successfully capture the thrombus. LESSONS A stent retriever with a closed-tip structure can effectively capture thrombi, making it a suitable distal embolic protection device in the posterior circulation.","PeriodicalId":16554,"journal":{"name":"Journal of Neurosurgery: Case Lessons","volume":"270 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel use of a closed-tip stent retriever to prevent distal embolism in the posterior circulation: illustrative case\",\"authors\":\"Rikuo Nishii, Masanori Goto, Yuki Takano, Kota Nakajima, Takateru Takamatsu, Masanori Tokuda, Hikari Tomita, Mai Yoshimoto, Satohiro Kawade, Yasuhiro Yamamoto, Yuji Naramoto, Kunimasa Teranishi, Nobuyuki Fukui, T. Sunohara, R. Fukumitsu, Junichi Takeda, Masaomi Koyanagi, C. Sakai, Nobuyuki Sakai, T. Ohta\",\"doi\":\"10.3171/CASE24137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND In mechanical thrombectomy for tandem occlusions in vertebrobasilar stroke, distal emboli from the vertebral artery lesion should be prevented. However, no suitable embolic protection devices are currently available in the posterior circulation. Here, the authors describe the case of a vertebral artery lesion effectively treated with a closed-tip stent retriever as an embolic protection device in the posterior circulation. OBSERVATIONS A 65-year-old male underwent mechanical thrombectomy for basilar artery occlusion, with tandem occlusion of the proximal vertebral artery. After basilar artery recanalization via the nonoccluded vertebral artery, a subsequent mechanical thrombectomy was performed for the occluded proximal vertebral artery. To prevent distal embolization of the basilar artery, an EmboTrap III stent retriever was deployed as an embolic protection device within the basilar artery to successfully capture the thrombus. LESSONS A stent retriever with a closed-tip structure can effectively capture thrombi, making it a suitable distal embolic protection device in the posterior circulation.\",\"PeriodicalId\":16554,\"journal\":{\"name\":\"Journal of Neurosurgery: Case Lessons\",\"volume\":\"270 5\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neurosurgery: Case Lessons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3171/CASE24137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurosurgery: Case Lessons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3171/CASE24137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景 在对椎基底动脉卒中的串联闭塞进行机械取栓术时,应防止椎动脉病变造成远端栓塞。然而,目前还没有合适的后循环栓塞保护装置。在此,作者描述了一例在后循环中使用闭合顶端支架回取器作为栓塞保护装置有效治疗椎动脉病变的病例。观察 一名 65 岁的男性因基底动脉闭塞接受了机械性血栓切除术,同时伴有椎动脉近端串联闭塞。在通过未闭塞的椎动脉对基底动脉进行再通后,又对闭塞的近端椎动脉进行了机械取栓术。为防止基底动脉远端栓塞,在基底动脉内部署了 EmboTrap III 支架回取器作为栓塞保护装置,以成功捕获血栓。启示 具有闭合顶端结构的支架回取器可以有效捕获血栓,因此适合作为后循环的远端栓塞保护装置。
Novel use of a closed-tip stent retriever to prevent distal embolism in the posterior circulation: illustrative case
BACKGROUND In mechanical thrombectomy for tandem occlusions in vertebrobasilar stroke, distal emboli from the vertebral artery lesion should be prevented. However, no suitable embolic protection devices are currently available in the posterior circulation. Here, the authors describe the case of a vertebral artery lesion effectively treated with a closed-tip stent retriever as an embolic protection device in the posterior circulation. OBSERVATIONS A 65-year-old male underwent mechanical thrombectomy for basilar artery occlusion, with tandem occlusion of the proximal vertebral artery. After basilar artery recanalization via the nonoccluded vertebral artery, a subsequent mechanical thrombectomy was performed for the occluded proximal vertebral artery. To prevent distal embolization of the basilar artery, an EmboTrap III stent retriever was deployed as an embolic protection device within the basilar artery to successfully capture the thrombus. LESSONS A stent retriever with a closed-tip structure can effectively capture thrombi, making it a suitable distal embolic protection device in the posterior circulation.