光伏系统遮光时各种直流斩波器的行为

S. Khader, A. Daud
{"title":"光伏系统遮光时各种直流斩波器的行为","authors":"S. Khader, A. Daud","doi":"10.37394/23201.2024.23.6","DOIUrl":null,"url":null,"abstract":"This paper investigates how the DC choppers behave during the shading occurrence at different time intervals of the year. Three types of DC choppers are implemented during the same shading conditions and intervals of time. The studied parameters are the duty cycle, output power, current, and switch losses. The mathematical model is built and implemented using the MATLAB/Simulink platform. The obtained results show that the SEPIC converter has the highest rate of duty cycle, which means more switching losses are generated. Concerning the average output power, the Modified Single Ended Primary Converter (MSEPIC) has the highest rate, while the Boost Converter has the lowest rate. The MPP power, duty cycle, and switching losses are studied under various shading rates. The duty cycle has the highest rate on the SEPIC converter, while MSEPIC has the lowest rate. Despite that, the switching losses are tremendously high at MSEPIC compared to SEPIC converters. Furthermore, simulation studies show that Boost and SEPIC converters have better performance in frequent cloudy weather conditions.","PeriodicalId":509697,"journal":{"name":"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS","volume":"16 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Behaviours of Various DC Choppers during Shading Occurrence in PV Systems\",\"authors\":\"S. Khader, A. Daud\",\"doi\":\"10.37394/23201.2024.23.6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates how the DC choppers behave during the shading occurrence at different time intervals of the year. Three types of DC choppers are implemented during the same shading conditions and intervals of time. The studied parameters are the duty cycle, output power, current, and switch losses. The mathematical model is built and implemented using the MATLAB/Simulink platform. The obtained results show that the SEPIC converter has the highest rate of duty cycle, which means more switching losses are generated. Concerning the average output power, the Modified Single Ended Primary Converter (MSEPIC) has the highest rate, while the Boost Converter has the lowest rate. The MPP power, duty cycle, and switching losses are studied under various shading rates. The duty cycle has the highest rate on the SEPIC converter, while MSEPIC has the lowest rate. Despite that, the switching losses are tremendously high at MSEPIC compared to SEPIC converters. Furthermore, simulation studies show that Boost and SEPIC converters have better performance in frequent cloudy weather conditions.\",\"PeriodicalId\":509697,\"journal\":{\"name\":\"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS\",\"volume\":\"16 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37394/23201.2024.23.6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37394/23201.2024.23.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了直流斩波器在一年中不同时间间隔内发生遮光时的表现。在相同的遮光条件和时间间隔内,使用了三种直流斩波器。研究参数包括占空比、输出功率、电流和开关损耗。数学模型是利用 MATLAB/Simulink 平台建立和实现的。结果表明,SEPIC 转换器的占空比最高,这意味着会产生更多的开关损耗。关于平均输出功率,改进型单端初级转换器(MSEPIC)的比率最高,而升压转换器的比率最低。研究了不同遮光率下的 MPP 功率、占空比和开关损耗。SEPIC 转换器的占空比最高,而 MSEPIC 的占空比最低。尽管如此,与 SEPIC 转换器相比,MSEPIC 的开关损耗非常高。此外,模拟研究表明,Boost 和 SEPIC 转换器在多云天气条件下的性能更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Behaviours of Various DC Choppers during Shading Occurrence in PV Systems
This paper investigates how the DC choppers behave during the shading occurrence at different time intervals of the year. Three types of DC choppers are implemented during the same shading conditions and intervals of time. The studied parameters are the duty cycle, output power, current, and switch losses. The mathematical model is built and implemented using the MATLAB/Simulink platform. The obtained results show that the SEPIC converter has the highest rate of duty cycle, which means more switching losses are generated. Concerning the average output power, the Modified Single Ended Primary Converter (MSEPIC) has the highest rate, while the Boost Converter has the lowest rate. The MPP power, duty cycle, and switching losses are studied under various shading rates. The duty cycle has the highest rate on the SEPIC converter, while MSEPIC has the lowest rate. Despite that, the switching losses are tremendously high at MSEPIC compared to SEPIC converters. Furthermore, simulation studies show that Boost and SEPIC converters have better performance in frequent cloudy weather conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信