Dong Soon Jang, Seung-Hun Sheen, Inbo Han, S. Lee, Woo Seok Choi, M. Bock, Seil Sohn
{"title":"硬脑膜密封剂系统 (DuraSeal®) 术后引起的胸脊髓压迫:病例报告和文献综述","authors":"Dong Soon Jang, Seung-Hun Sheen, Inbo Han, S. Lee, Woo Seok Choi, M. Bock, Seil Sohn","doi":"10.21129/nerve.2024.00535","DOIUrl":null,"url":null,"abstract":", hindering the improvement of the surgical site and increasing the possibility of infection. DuraSeal ® is a dural sealing adhesive that prevents CSF leakage and is used as an adjunct to enable the watertight repair of dural defects when the dura is damaged during spinal surgery. In the present case, DuraSeal ® was applied to repair a dural defect in the surgical area after thoracic spine surgery, and no neurological problems occurred immediately after surgery. However, a day later, the patient’s paraparesis worsened; therefore, reoperation was performed and the symptoms improved.","PeriodicalId":497989,"journal":{"name":"The nerve","volume":"44 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Postoperative Thoracic Cord Compression Induced by a Dural Sealant System (DuraSeal®): A Case Report and Literature Review\",\"authors\":\"Dong Soon Jang, Seung-Hun Sheen, Inbo Han, S. Lee, Woo Seok Choi, M. Bock, Seil Sohn\",\"doi\":\"10.21129/nerve.2024.00535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\", hindering the improvement of the surgical site and increasing the possibility of infection. DuraSeal ® is a dural sealing adhesive that prevents CSF leakage and is used as an adjunct to enable the watertight repair of dural defects when the dura is damaged during spinal surgery. In the present case, DuraSeal ® was applied to repair a dural defect in the surgical area after thoracic spine surgery, and no neurological problems occurred immediately after surgery. However, a day later, the patient’s paraparesis worsened; therefore, reoperation was performed and the symptoms improved.\",\"PeriodicalId\":497989,\"journal\":{\"name\":\"The nerve\",\"volume\":\"44 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The nerve\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.21129/nerve.2024.00535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The nerve","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.21129/nerve.2024.00535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Postoperative Thoracic Cord Compression Induced by a Dural Sealant System (DuraSeal®): A Case Report and Literature Review
, hindering the improvement of the surgical site and increasing the possibility of infection. DuraSeal ® is a dural sealing adhesive that prevents CSF leakage and is used as an adjunct to enable the watertight repair of dural defects when the dura is damaged during spinal surgery. In the present case, DuraSeal ® was applied to repair a dural defect in the surgical area after thoracic spine surgery, and no neurological problems occurred immediately after surgery. However, a day later, the patient’s paraparesis worsened; therefore, reoperation was performed and the symptoms improved.